Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes

Descripción del Articulo

El presente trabajo tiene por finalidad estudiar el desempeño sísmico en columnas circulares de concreto armado y presforzado en puentes, el postensado es un tipo de presfuerzo, del cual existen dos sistemas que son el sistema adherido y no adherido. Para ello se hizo la revisión a las normativas AA...

Descripción completa

Detalles Bibliográficos
Autor: Atalaya Villanueva, José Narciso
Formato: tesis de maestría
Fecha de Publicación:2024
Institución:Universidad Nacional de Ingeniería
Repositorio:UNI-Tesis
Lenguaje:español
OAI Identifier:oai:cybertesis.uni.edu.pe:20.500.14076/28720
Enlace del recurso:http://hdl.handle.net/20.500.14076/28720
Nivel de acceso:acceso abierto
Materia:Ingeniería sísmica
Columnas de concreto armado
Comportamiento sísmico
Concreto postensado
Puentes
Propiedades mecánicas
https://purl.org/pe-repo/ocde/ford#2.01.04
id UUNI_33d0e1e10284f6646c6913fe023dea9c
oai_identifier_str oai:cybertesis.uni.edu.pe:20.500.14076/28720
network_acronym_str UUNI
network_name_str UNI-Tesis
repository_id_str 1534
dc.title.es.fl_str_mv Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
title Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
spellingShingle Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
Atalaya Villanueva, José Narciso
Ingeniería sísmica
Columnas de concreto armado
Comportamiento sísmico
Concreto postensado
Puentes
Propiedades mecánicas
https://purl.org/pe-repo/ocde/ford#2.01.04
title_short Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
title_full Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
title_fullStr Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
title_full_unstemmed Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
title_sort Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentes
dc.creator.none.fl_str_mv Atalaya Villanueva, José Narciso
author Atalaya Villanueva, José Narciso
author_facet Atalaya Villanueva, José Narciso
author_role author
dc.contributor.advisor.fl_str_mv Flores González, Leonardo
dc.contributor.author.fl_str_mv Atalaya Villanueva, José Narciso
dc.subject.es.fl_str_mv Ingeniería sísmica
Columnas de concreto armado
Comportamiento sísmico
Concreto postensado
Puentes
Propiedades mecánicas
topic Ingeniería sísmica
Columnas de concreto armado
Comportamiento sísmico
Concreto postensado
Puentes
Propiedades mecánicas
https://purl.org/pe-repo/ocde/ford#2.01.04
dc.subject.ocde.es.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.01.04
description El presente trabajo tiene por finalidad estudiar el desempeño sísmico en columnas circulares de concreto armado y presforzado en puentes, el postensado es un tipo de presfuerzo, del cual existen dos sistemas que son el sistema adherido y no adherido. Para ello se hizo la revisión a las normativas AASTHO y el ACI 318-19 para el diseño de estas y también para el estudio de su desempeño sísmico se consideró el procedimiento simplificado para el cálculo de la distorsión ultima y del momento máximo probable para columnas de concreto armado, basándonos en el modelo sugerido por el Dr. José Restrepo y el Dr. Mario Rodríguez y para columnas de concreto postensado por el Dr. Miguel Torres. Para el análisis se consideró un puente cuya subestructura está conformada por pilares tipo pórtico (con columnas), los cuales se diseñarán para poder reproducir los modelos no lineales (no linealidad concentrada o rótulas plásticas), a partir de las propiedades constitutivas de los materiales (relaciones esfuerzo-deformación). y las expresiones de curvatura ultima y máximo momento probable que están calibradas para cargas laterales de naturaleza reversible o cíclicas. Finally, by means of a nonlinear incremental static analysis (NLIA) and the Capacity Spectrum Method (CSM), the performance points and ductility levels of the structures will be found. This will allow us to understand which system presents a better seismic performance, the advantages and disadvantages of the use of prestressing in the columns.
publishDate 2024
dc.date.accessioned.none.fl_str_mv 2025-11-26T23:40:11Z
dc.date.available.none.fl_str_mv 2025-11-26T23:40:11Z
dc.date.issued.fl_str_mv 2024
dc.type.es.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/20.500.14076/28720
url http://hdl.handle.net/20.500.14076/28720
dc.language.iso.es.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.format.es.fl_str_mv application/pdf
dc.publisher.es.fl_str_mv Universidad Nacional de Ingeniería
dc.publisher.country.es.fl_str_mv PE
dc.source.es.fl_str_mv Universidad Nacional de Ingeniería
Repositorio Institucional - UNI
dc.source.none.fl_str_mv reponame:UNI-Tesis
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str UNI-Tesis
collection UNI-Tesis
bitstream.url.fl_str_mv http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/6/atalaya_vj.pdf.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/7/atalaya_vj%28acta%29.pdf.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/8/informe_de_similitud.pdf.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/9/carta_de_autorizaci%c3%b3n.pdf.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/5/license.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/1/atalaya_vj.pdf
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/2/atalaya_vj%28acta%29.pdf
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/3/informe_de_similitud.pdf
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/4/carta_de_autorizaci%c3%b3n.pdf
bitstream.checksum.fl_str_mv f9b2149f2ebef2414dfe93d7c7e219df
0814c77ab422d45fdea4c7838b7952f7
ada8e01b8aef404c81f75b98640b657b
72243deafa4410652dd79f43a7193fb4
8a4605be74aa9ea9d79846c1fba20a33
9052d305cedcb57018e0c33957f1fca1
d6089aca967ce868b9c5b7cfffd7b390
eaf587595a3c43ca1757809d1c307011
30c8d73e18831fc0a21ce1001aba9beb
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNI
repository.mail.fl_str_mv repositorio@uni.edu.pe
_version_ 1850866485237383168
spelling Flores González, LeonardoAtalaya Villanueva, José NarcisoAtalaya Villanueva, José Narciso2025-11-26T23:40:11Z2025-11-26T23:40:11Z2024http://hdl.handle.net/20.500.14076/28720El presente trabajo tiene por finalidad estudiar el desempeño sísmico en columnas circulares de concreto armado y presforzado en puentes, el postensado es un tipo de presfuerzo, del cual existen dos sistemas que son el sistema adherido y no adherido. Para ello se hizo la revisión a las normativas AASTHO y el ACI 318-19 para el diseño de estas y también para el estudio de su desempeño sísmico se consideró el procedimiento simplificado para el cálculo de la distorsión ultima y del momento máximo probable para columnas de concreto armado, basándonos en el modelo sugerido por el Dr. José Restrepo y el Dr. Mario Rodríguez y para columnas de concreto postensado por el Dr. Miguel Torres. Para el análisis se consideró un puente cuya subestructura está conformada por pilares tipo pórtico (con columnas), los cuales se diseñarán para poder reproducir los modelos no lineales (no linealidad concentrada o rótulas plásticas), a partir de las propiedades constitutivas de los materiales (relaciones esfuerzo-deformación). y las expresiones de curvatura ultima y máximo momento probable que están calibradas para cargas laterales de naturaleza reversible o cíclicas. Finally, by means of a nonlinear incremental static analysis (NLIA) and the Capacity Spectrum Method (CSM), the performance points and ductility levels of the structures will be found. This will allow us to understand which system presents a better seismic performance, the advantages and disadvantages of the use of prestressing in the columns.The purpose of this work is to study the seismic performance of reinforced and prestressed concrete circular columns in bridges; post-tensioning is a type of prestressing, of which there are two systems: bonded and unbonded. For this purpose, the AASTHO and ACI 318- 19 standards were reviewed for the design of these and also for the study of their seismic performance, the simplified procedure for the calculation of the ultimate distortion and the maximum probable moment for reinforced concrete columns was considered, based on the model suggested by Dr. José Restrepo and Dr. Mario Rodríguez and for post-tensioned concrete columns by Dr. Miguel Torres. For the analysis we considered a bridge whose substructure is formed by gantry-type columns (with columns), which will be designed to reproduce the nonlinear models (concentrated nonlinearity or plastic hinges), based on the constitutive properties of the materials (stress-strain relationships) and the expressions of ultimate curvature and maximum probable moment that are calibrated for lateral loads of a reversible or cyclic nature. Finally, through a nonlinear incremental static analysis (AEINL) and the Capacity Spectrum Method (MEC) the performance points and ductility levels of the structures will be found. Which will allow us to understand which system better seismic performance has, the advantages and disadvantages of using prestress in the columns.Submitted by Quispe Rabanal Flavio (flaviofime@hotmail.com) on 2025-11-26T23:40:11Z No. of bitstreams: 4 atalaya_vj.pdf: 8853959 bytes, checksum: 9052d305cedcb57018e0c33957f1fca1 (MD5) atalaya_vj(acta).pdf: 400619 bytes, checksum: d6089aca967ce868b9c5b7cfffd7b390 (MD5) informe_de_similitud.pdf: 1391042 bytes, checksum: eaf587595a3c43ca1757809d1c307011 (MD5) carta_de_autorización.pdf: 211741 bytes, checksum: 30c8d73e18831fc0a21ce1001aba9beb (MD5)Made available in DSpace on 2025-11-26T23:40:11Z (GMT). No. of bitstreams: 4 atalaya_vj.pdf: 8853959 bytes, checksum: 9052d305cedcb57018e0c33957f1fca1 (MD5) atalaya_vj(acta).pdf: 400619 bytes, checksum: d6089aca967ce868b9c5b7cfffd7b390 (MD5) informe_de_similitud.pdf: 1391042 bytes, checksum: eaf587595a3c43ca1757809d1c307011 (MD5) carta_de_autorización.pdf: 211741 bytes, checksum: 30c8d73e18831fc0a21ce1001aba9beb (MD5) Previous issue date: 2024Tesisapplication/pdfspaUniversidad Nacional de IngenieríaPEinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/Universidad Nacional de IngenieríaRepositorio Institucional - UNIreponame:UNI-Tesisinstname:Universidad Nacional de Ingenieríainstacron:UNIIngeniería sísmicaColumnas de concreto armadoComportamiento sísmicoConcreto postensadoPuentesPropiedades mecánicashttps://purl.org/pe-repo/ocde/ford#2.01.04Desempeño sísmico de columnas circulares de concreto postensado con el sistema adherido y no adherido en puentesinfo:eu-repo/semantics/masterThesisSUNEDUMaestro en Ciencias con Mención en Ingeniería EstructuralUniversidad Nacional de Ingeniería. Facultad de Ingeniería Civil. Unidad de PosgradoMaestríaMaestría en Ciencias con Mención en Ingeniería EstructuralMaestríahttps://orcid.org/0000-0002-9290-53540985780744706378https://purl.org/pe-repo/renati/type#tesishttps://purl.org/pe-repo/renati/level#maestro732097Torres Matos, Miguel ÁngelScaletti Farina, Hugo Víctor LuisJiménez Yábar, Heddy MarcelaGutiérrez Lázares, José WilfredoTEXTatalaya_vj.pdf.txtatalaya_vj.pdf.txtExtracted texttext/plain306384http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/6/atalaya_vj.pdf.txtf9b2149f2ebef2414dfe93d7c7e219dfMD56atalaya_vj(acta).pdf.txtatalaya_vj(acta).pdf.txtExtracted texttext/plain1683http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/7/atalaya_vj%28acta%29.pdf.txt0814c77ab422d45fdea4c7838b7952f7MD57informe_de_similitud.pdf.txtinforme_de_similitud.pdf.txtExtracted texttext/plain1188http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/8/informe_de_similitud.pdf.txtada8e01b8aef404c81f75b98640b657bMD58carta_de_autorización.pdf.txtcarta_de_autorización.pdf.txtExtracted texttext/plain2729http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/9/carta_de_autorizaci%c3%b3n.pdf.txt72243deafa4410652dd79f43a7193fb4MD59LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/5/license.txt8a4605be74aa9ea9d79846c1fba20a33MD55ORIGINALatalaya_vj.pdfatalaya_vj.pdfapplication/pdf8853959http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/1/atalaya_vj.pdf9052d305cedcb57018e0c33957f1fca1MD51atalaya_vj(acta).pdfatalaya_vj(acta).pdfapplication/pdf400619http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/2/atalaya_vj%28acta%29.pdfd6089aca967ce868b9c5b7cfffd7b390MD52informe_de_similitud.pdfinforme_de_similitud.pdfapplication/pdf1391042http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/3/informe_de_similitud.pdfeaf587595a3c43ca1757809d1c307011MD53carta_de_autorización.pdfcarta_de_autorización.pdfapplication/pdf211741http://cybertesis.uni.edu.pe/bitstream/20.500.14076/28720/4/carta_de_autorizaci%c3%b3n.pdf30c8d73e18831fc0a21ce1001aba9bebMD5420.500.14076/28720oai:cybertesis.uni.edu.pe:20.500.14076/287202025-11-27 05:07:30.572Repositorio Institucional - UNIrepositorio@uni.edu.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
score 13.44655
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).