Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería

Descripción del Articulo

In this research evaluates the granulometry influence and replacement percentage of recycled brick on the compressive strength, absorption and capillarity in the manufacture of mortars for masonry plastering. Searching alternatives that improve the impact waste brick's as a contaminant on human...

Descripción completa

Detalles Bibliográficos
Autores: Bocanegra Mariños, Jahir Andreé, Espejo Valdez, Yeyson Antony
Formato: tesis de grado
Fecha de Publicación:2018
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/10482
Enlace del recurso:https://hdl.handle.net/20.500.14414/10482
Nivel de acceso:acceso abierto
Materia:Enlucidos de albañileria
id UNIT_4b978edd6d2d58f78397fedec5bc92ca
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/10482
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_PE.fl_str_mv Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
title Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
spellingShingle Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
Bocanegra Mariños, Jahir Andreé
Enlucidos de albañileria
title_short Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
title_full Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
title_fullStr Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
title_full_unstemmed Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
title_sort Influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería
author Bocanegra Mariños, Jahir Andreé
author_facet Bocanegra Mariños, Jahir Andreé
Espejo Valdez, Yeyson Antony
author_role author
author2 Espejo Valdez, Yeyson Antony
author2_role author
dc.contributor.advisor.fl_str_mv Vasquez Alfaro, Iván Eugenio
dc.contributor.author.fl_str_mv Bocanegra Mariños, Jahir Andreé
Espejo Valdez, Yeyson Antony
dc.subject.es_PE.fl_str_mv Enlucidos de albañileria
topic Enlucidos de albañileria
description In this research evaluates the granulometry influence and replacement percentage of recycled brick on the compressive strength, absorption and capillarity in the manufacture of mortars for masonry plastering. Searching alternatives that improve the impact waste brick's as a contaminant on human health and the environment, it is proposed to achieve a more sustainable construction model using recycled brick to produce an alternative mortar with lower production costs and improved the masonry mortars properties. The purpose of this research was to determine the optimum granulometric size and adequate recycled brick's percentage that should replace fine sand in the design of a conventional mortar for plastering mortars. The granulometries evaluated of the recycled brick passed meshes Nº 30, Nº 50 and Nº 100; using replacement percentages of 3, 6, 9, 12, 15 and 18%, with a cement dosage type ICo:fine sand 1: 3 and ratio a/c = 0.80 Shaping and compressive strength mortar test were used 5 x 5 x 5 cm cubes under the ASTM C109 standard, the absorption was determined by ASTM C642 standard and capillarity, ASTM C1585. The specimens were tested at the end of 28 days; except for the compressive strength that were tested at 1, 3 y 7 and 28 days, wich were cured and under environmental conditions. The optimal mortars design with recycled brick was achieved with 18% percentage and a granulometry that passed mesh Nº 100, managing to increase the compressive strength from 244 kg/cm2 to 310 kg/cm2, decrease the absorption from 7.2% to 4.7% and at the same time reduce the capillarity coefficient from 0.0006 g/mm2 x h1/2 to 0.0003 g/mm2 x h1/2.
publishDate 2018
dc.date.accessioned.none.fl_str_mv 2018-08-02T14:49:08Z
dc.date.available.none.fl_str_mv 2018-08-02T14:49:08Z
dc.date.issued.fl_str_mv 2018-04
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/10482
url https://hdl.handle.net/20.500.14414/10482
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.relation.ispartofseries.none.fl_str_mv Tciv;Tciv
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.es_PE.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_PE.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/53aa620c-3e9e-4e28-9f93-b0c3b17fdd18/download
https://dspace.unitru.edu.pe/bitstreams/e59b09cc-758a-481b-9fc1-c2f32a4e4bc1/download
bitstream.checksum.fl_str_mv dcf55f8f921f04a7417602dcdd85a9ac
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290379072962560
spelling Vasquez Alfaro, Iván EugenioBocanegra Mariños, Jahir AndreéEspejo Valdez, Yeyson Antony2018-08-02T14:49:08Z2018-08-02T14:49:08Z2018-04https://hdl.handle.net/20.500.14414/10482In this research evaluates the granulometry influence and replacement percentage of recycled brick on the compressive strength, absorption and capillarity in the manufacture of mortars for masonry plastering. Searching alternatives that improve the impact waste brick's as a contaminant on human health and the environment, it is proposed to achieve a more sustainable construction model using recycled brick to produce an alternative mortar with lower production costs and improved the masonry mortars properties. The purpose of this research was to determine the optimum granulometric size and adequate recycled brick's percentage that should replace fine sand in the design of a conventional mortar for plastering mortars. The granulometries evaluated of the recycled brick passed meshes Nº 30, Nº 50 and Nº 100; using replacement percentages of 3, 6, 9, 12, 15 and 18%, with a cement dosage type ICo:fine sand 1: 3 and ratio a/c = 0.80 Shaping and compressive strength mortar test were used 5 x 5 x 5 cm cubes under the ASTM C109 standard, the absorption was determined by ASTM C642 standard and capillarity, ASTM C1585. The specimens were tested at the end of 28 days; except for the compressive strength that were tested at 1, 3 y 7 and 28 days, wich were cured and under environmental conditions. The optimal mortars design with recycled brick was achieved with 18% percentage and a granulometry that passed mesh Nº 100, managing to increase the compressive strength from 244 kg/cm2 to 310 kg/cm2, decrease the absorption from 7.2% to 4.7% and at the same time reduce the capillarity coefficient from 0.0006 g/mm2 x h1/2 to 0.0003 g/mm2 x h1/2.En la presente investigación se evalúa la influencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañilería. Como búsqueda de alternativas que mejoren el impacto que tienen los residuos de ladrillo como contaminantes sobre la salud humana y el medio ambiente, se plantea conseguir un modelo de construcción más sostenible con el uso del ladrillo reciclado para producir un mortero alternativo a bajos costos de producción y con propiedades mejoradas a la de un mortero de albañilería tradicional. El propósito de la investigación fue determinar el tamaño granulométrico óptimo y porcentaje adecuado de ladrillo reciclado que debe sustituir a la arena fina en el diseño de una mezcla convencional para morteros de enlucidos. Las granulometrías evaluadas del ladrillo reciclado pasaron las mallas Nº 30, Nº 50 y Nº 100; utilizando porcentajes de reemplazo de 3, 6, 9, 12, 15 y 18%, con una dosificación de cemento Tipo ICo:arena fina 1:3 y relación a/c = 0.80. Para el conformado y el ensayo de resistencia a la compresión del mortero se utilizaron cubos de 5 x 5 x 5 cm bajo la norma ASTM C109, para determinar la absorción se usó la norma ASTM C642 y para la capilaridad se usó la ASTM C1585. Las probetas fueron ensayadas a una edad de 28 días; a excepción del ensayo de compresión donde se ensayaron a edades de 1, 3, 7 y 28 días, las cuales estuvieron curadas y bajo condiciones ambientales. El diseño óptimo del mortero con ladrillo reciclado se logró con un porcentaje al 18% y una granulometría pasante la malla Nº 100; logrando aumentar la resistencia a la compresión de 244 kg/cm2 a 310 kg/cm2, disminuir la absorción de 7.2% a 4.7% y a la vez reducir el coeficiente de capilaridad de 0.0006 g/mm2 x h1/2 a 0.0003 g/mm2 x h1/2.TesisspaUniversidad Nacional de TrujilloTciv;TcivSUNEDUinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUEnlucidos de albañileriaInfluencia de la granulometría y el porcentaje de reemplazo de ladrillo reciclado sobre la resistencia a la compresión, absorción y capilaridad en la fabricación de morteros para enlucidos de albañileríainfo:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero CivilIngenieríaUniversidad Nacional de Trujillo. Facultad de IngenieríaORIGINALBOCANEGRA MARIÑOS, Jahir Andreé; ESPEJO VALDEZ, Yeyson Antony.pdfBOCANEGRA MARIÑOS, Jahir Andreé; ESPEJO VALDEZ, Yeyson Antony.pdfEnlucidosapplication/pdf11076651https://dspace.unitru.edu.pe/bitstreams/53aa620c-3e9e-4e28-9f93-b0c3b17fdd18/downloaddcf55f8f921f04a7417602dcdd85a9acMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/e59b09cc-758a-481b-9fc1-c2f32a4e4bc1/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/10482oai:dspace.unitru.edu.pe:20.500.14414/104822018-08-02 09:49:08.179http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.905282
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).