Evaluation of the peripheral dose for radiosurgery treatments in simulated targets in different positions of the head of a phantom

Descripción del Articulo

In radiosurgery treatments, there is always an absorbed dose (D) that is deposited outside the treatment field, this D is known as "Peripheral Dose" (PD). The objective of this work was to evaluate PD in 9 anatomical positions (eyes, thyroid, upper lungs, mediastinum, breasts and navel) of...

Descripción completa

Detalles Bibliográficos
Autores: Querebalú, Cecilia, Solano, Javier, Márquez, Fernando
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/343
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/343
Nivel de acceso:acceso abierto
Materia:radiocirugía
dosis periférica
películas radiocrómicas EBT2
radiosurgery
peripheral dose
EBT2 radiochromic films
Descripción
Sumario:In radiosurgery treatments, there is always an absorbed dose (D) that is deposited outside the treatment field, this D is known as "Peripheral Dose" (PD). The objective of this work was to evaluate PD in 9 anatomical positions (eyes, thyroid, upper lungs, mediastinum, breasts and navel) of an anthropomorphic phantom. The development of the work contemplates the use of the EBT2 radiochromic films, and a photon beam of 6 MV generated in a linear accelerator Clinac 2100C / D. Analyzing the influence of collimator size, greater DP ((150.81 ± 0.97) cGy) was found in the right eye of the phantom for the collimator of 3 cm with a target fixed in the upper right plane of the head of the phantom and its influence with the distance of, a PD of (27.14 ± 1.04) cGy in the thyroid, for a target positioned in the lower left plane of the phantom head for a prescribed dose of 18 Gy. It is concluded that to carry out the optimization during the procedure in radiosurgery it is necessary to know the dependence of the PD with respect to the location of the target, the size of collimator and the distance. 
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).