Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú
Descripción del Articulo
The present research aims is to determine the impact that passive heating strategies would have on the thermal comfort of residents in high Andean homes in Sabaino Apurímac, which are characterized by having a cold climate and also being exposed to the problem of frost typical of said places. This r...
Autor: | |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2024 |
Institución: | Universidad Nacional Federico Villarreal |
Repositorio: | Revistas - Universidad Nacional Federico Villarreal |
Lenguaje: | español |
OAI Identifier: | oai:ojs2.revistas.unfv.edu.pe:article/1629 |
Enlace del recurso: | https://revistas.unfv.edu.pe/RCV/article/view/1629 |
Nivel de acceso: | acceso abierto |
id |
REVUNFV_91a6d893a2ecbf3ad042ad0b8a8b35cb |
---|---|
oai_identifier_str |
oai:ojs2.revistas.unfv.edu.pe:article/1629 |
network_acronym_str |
REVUNFV |
network_name_str |
Revistas - Universidad Nacional Federico Villarreal |
repository_id_str |
. |
spelling |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- PerúEstrategias de calefacción pasiva y su impacto en el confort térmico en viviendas altoandinas en Apurímac-Perúcerron contreras, amandaThe present research aims is to determine the impact that passive heating strategies would have on the thermal comfort of residents in high Andean homes in Sabaino Apurímac, which are characterized by having a cold climate and also being exposed to the problem of frost typical of said places. This research is of a non-experimental design, of a descriptive correlational type and non-probabilistic sampling. Measurements of the thermal variables were carried out in the place of study to analyze the current situation faced in said areas and a survey carried out with 34 specialists in the area to establish which are the most optimal passive heating strategies that would be suitable for high Andean areas to achieve a improvement in thermal comfort in homes. The results show that passive heating strategies would significantly influence the thermal comfort of residents in high Andean homes, likewise it is concluded that the most suitable strategies that can be implemented in homes already built are overhead skylights, attached greenhouses, direct intake to through the windows facing N, E and W are more efficient; together with the incorporation of insulating material in the envelope to achieve temperature increases of up to approximately 10°C.La presente investigación tiene como objetivo determinar el impacto que tendrían las estrategias de calefacción pasiva en el confort térmico de los pobladores en viviendas alto andinas en Sabaino Apurímac, que se caracterizan por tener un clima frio y además estar expuestos al problema de las heladas propias de dichos lugares. Esta investigación es de diseño no experimental, de tipo descriptivo correlacional y muestreo no probabilístico. Se realizó mediciones de las variables térmicas en el lugar de estudio para analizar la situación actual que enfrentan en dichas zonas y una encuesta realizada a 34 especialistas del área para establecer cuáles son las estrategias pasivas de calentamiento más óptimos que se adecuarían para zonas altoandinas para lograr una mejora en el confort térmico en las viviendas. Los resultados muestran que la estrategias de calefacción pasiva influirían significativamente en el confort térmico de los pobladores en viviendas altoandinas, asimismo se concluye que las estrategias más idóneas que pueden ser implementadas en viviendas ya construidas son los tragaluces cenitales, invernaderos adosados, la captación directa a través de las ventanas orientadas al N, E y O son más eficientes; en conjunto con la incorporación de material aislante en la envolvente para lograr incrementos de temperatura de hasta 10°C aproximadamente.Universidad Nacional Federico Villarreal2024-04-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlapplication/epub+ziphttps://revistas.unfv.edu.pe/RCV/article/view/1629Cátedra Villarreal; Vol. 11 No. 2 (2023): Cátedra Villarreal; 80-88Cátedra Villarreal; Vol. 11 Núm. 2 (2023): Cátedra Villarreal; 80-882311-22122310-4767reponame:Revistas - Universidad Nacional Federico Villarrealinstname:Universidad Nacional Federico Villarrealinstacron:UNFVspahttps://revistas.unfv.edu.pe/RCV/article/view/1629/2973https://revistas.unfv.edu.pe/RCV/article/view/1629/2974https://revistas.unfv.edu.pe/RCV/article/view/1629/2975Derechos de autor 2023 amanda cerron contrerashttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:ojs2.revistas.unfv.edu.pe:article/16292024-05-08T13:52:59Z |
dc.title.none.fl_str_mv |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú Estrategias de calefacción pasiva y su impacto en el confort térmico en viviendas altoandinas en Apurímac-Perú |
title |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú |
spellingShingle |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú cerron contreras, amanda |
title_short |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú |
title_full |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú |
title_fullStr |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú |
title_full_unstemmed |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú |
title_sort |
Passive heating strategies and its impact on thermal comfort in high Andean houses in Apurimac- Perú |
dc.creator.none.fl_str_mv |
cerron contreras, amanda |
author |
cerron contreras, amanda |
author_facet |
cerron contreras, amanda |
author_role |
author |
description |
The present research aims is to determine the impact that passive heating strategies would have on the thermal comfort of residents in high Andean homes in Sabaino Apurímac, which are characterized by having a cold climate and also being exposed to the problem of frost typical of said places. This research is of a non-experimental design, of a descriptive correlational type and non-probabilistic sampling. Measurements of the thermal variables were carried out in the place of study to analyze the current situation faced in said areas and a survey carried out with 34 specialists in the area to establish which are the most optimal passive heating strategies that would be suitable for high Andean areas to achieve a improvement in thermal comfort in homes. The results show that passive heating strategies would significantly influence the thermal comfort of residents in high Andean homes, likewise it is concluded that the most suitable strategies that can be implemented in homes already built are overhead skylights, attached greenhouses, direct intake to through the windows facing N, E and W are more efficient; together with the incorporation of insulating material in the envelope to achieve temperature increases of up to approximately 10°C. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-04-23 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.unfv.edu.pe/RCV/article/view/1629 |
url |
https://revistas.unfv.edu.pe/RCV/article/view/1629 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.unfv.edu.pe/RCV/article/view/1629/2973 https://revistas.unfv.edu.pe/RCV/article/view/1629/2974 https://revistas.unfv.edu.pe/RCV/article/view/1629/2975 |
dc.rights.none.fl_str_mv |
Derechos de autor 2023 amanda cerron contreras https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2023 amanda cerron contreras https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf text/html application/epub+zip |
dc.publisher.none.fl_str_mv |
Universidad Nacional Federico Villarreal |
publisher.none.fl_str_mv |
Universidad Nacional Federico Villarreal |
dc.source.none.fl_str_mv |
Cátedra Villarreal; Vol. 11 No. 2 (2023): Cátedra Villarreal; 80-88 Cátedra Villarreal; Vol. 11 Núm. 2 (2023): Cátedra Villarreal; 80-88 2311-2212 2310-4767 reponame:Revistas - Universidad Nacional Federico Villarreal instname:Universidad Nacional Federico Villarreal instacron:UNFV |
instname_str |
Universidad Nacional Federico Villarreal |
instacron_str |
UNFV |
institution |
UNFV |
reponame_str |
Revistas - Universidad Nacional Federico Villarreal |
collection |
Revistas - Universidad Nacional Federico Villarreal |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1799319003905130496 |
score |
13.7786255 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).