OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS

Descripción del Articulo

The response surface methodology was applied to evaluate the optimal experimental conditions to remove persistent organic compounds from a synthetic textile wastewater using a batch photochemical reactor on a laboratory scale. Four factors at three levels were studied: Fenton H2O2/Fe2+ reagent ratio...

Descripción completa

Detalles Bibliográficos
Autores: Gutiérrez, César, Pilco, Alex
Formato: artículo
Fecha de Publicación:2020
Institución:Sociedad Química del Perú
Repositorio:Revista de la Sociedad Química del Perú
Lenguaje:español
OAI Identifier:oai:rsqp.revistas.sqperu.org.pe:article/273
Enlace del recurso:http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/273
Nivel de acceso:acceso abierto
Materia:Photo-Fenton
textile wastewater
experiment design
chemical oxygen demand
Foto-Fenton
agua residual textil
diseño de experimentos
emanda química de oxígeno
id REVSQP_1317762e426d2e3bc233bdf5fca7952d
oai_identifier_str oai:rsqp.revistas.sqperu.org.pe:article/273
network_acronym_str REVSQP
network_name_str Revista de la Sociedad Química del Perú
repository_id_str
spelling OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESSOPTIMIZACIÓN DE LA REMOCIÓN DE COMPUESTOS ORGÁNICOS PERSISTENTES MEDIANTE EL PROCESO FOTO-FENTONGutiérrez, CésarPilco, AlexPhoto-Fentontextile wastewaterexperiment designchemical oxygen demandFoto-Fentonagua residual textildiseño de experimentosemanda química de oxígenoThe response surface methodology was applied to evaluate the optimal experimental conditions to remove persistent organic compounds from a synthetic textile wastewater using a batch photochemical reactor on a laboratory scale. Four factors at three levels were studied: Fenton H2O2/Fe2+ reagent ratio (11,25, 18,75, 26,25 mg/L/mg/L), UV lamp power (4, 11, 18 W), pH (2, 3, 4) and treatment time (60, 120, 180 min). The optimum levels found for the four factors were: ratio of Fenton H2O2/Fe2+ reagents equal to 17 mg/L/mg/L, UV lamp power equal to 4 W, pH equal to 3 and treatment time of 180 min. It was found that the photo- Fenton process is very effective in treating synthetic textile wastewater, with a removal of 86 %, with respect to COD.La metodología de superficie de respuesta se aplicó para evaluar la condición óptima experimental a fin de remover los compuestos orgánicos persistentes de un agua residual textil sintética usando un reactor fotoquímico en lote a escala laboratorio. Cuatro factores a tres niveles fueron estudiados: relación de reactivos Fenton H2O2/Fe2+ (11,25, 18,75, 26,25 mg/L/mg/L), potencia de lámpara UV (4, 11, 18 W), pH (2, 3, 4) y tiempo de tratamiento (60, 120, 180 min). Los niveles óptimos encontrados para los cuatro factores fueron: relación de reactivos Fenton H2O2/Fe2+ igual a 17 mg/L/mg/L, potencia de lámpara UV igual a 4 W, pH igual a 3 y tiempo de tratamiento de 180 min. Se encontró que el proceso foto-Fenton es muy efectivo para tratar el agua residual textil sintética, encontrándose una remoción de un 86 %, respecto al DQO.Sociedad Química del Perú2020-03-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTexttextoapplication/pdfhttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/27310.37761/rsqp.v86i1.273Revista de la Sociedad Química del Perú; Vol. 86 Núm. 1 (2020): Revista de la Sociedad Química del Perú; 58 - 69Journal of the Chemical Society of Peru; Vol. 86 No. 1 (2020): Journal of Sociedad Química del Perú; 58 - 692309-87401810-634X10.37761/rsqp.v86i1reponame:Revista de la Sociedad Química del Perúinstname:Sociedad Química del Perúinstacron:SQPspahttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/273/23820202020Derechos de autor 2020 Sociedad Química del Perúhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:rsqp.revistas.sqperu.org.pe:article/2732020-07-31T15:48:12Z
dc.title.none.fl_str_mv OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
OPTIMIZACIÓN DE LA REMOCIÓN DE COMPUESTOS ORGÁNICOS PERSISTENTES MEDIANTE EL PROCESO FOTO-FENTON
title OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
spellingShingle OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
Gutiérrez, César
Photo-Fenton
textile wastewater
experiment design
chemical oxygen demand
Foto-Fenton
agua residual textil
diseño de experimentos
emanda química de oxígeno
title_short OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
title_full OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
title_fullStr OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
title_full_unstemmed OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
title_sort OPTIMIZATION OF THE REMOVAL OF PERSISTENT ORGANIC COMPOUNDS THROUGH THE PHOTO-FENTON PROCESS
dc.creator.none.fl_str_mv Gutiérrez, César
Pilco, Alex
author Gutiérrez, César
author_facet Gutiérrez, César
Pilco, Alex
author_role author
author2 Pilco, Alex
author2_role author
dc.subject.none.fl_str_mv Photo-Fenton
textile wastewater
experiment design
chemical oxygen demand
Foto-Fenton
agua residual textil
diseño de experimentos
emanda química de oxígeno
topic Photo-Fenton
textile wastewater
experiment design
chemical oxygen demand
Foto-Fenton
agua residual textil
diseño de experimentos
emanda química de oxígeno
description The response surface methodology was applied to evaluate the optimal experimental conditions to remove persistent organic compounds from a synthetic textile wastewater using a batch photochemical reactor on a laboratory scale. Four factors at three levels were studied: Fenton H2O2/Fe2+ reagent ratio (11,25, 18,75, 26,25 mg/L/mg/L), UV lamp power (4, 11, 18 W), pH (2, 3, 4) and treatment time (60, 120, 180 min). The optimum levels found for the four factors were: ratio of Fenton H2O2/Fe2+ reagents equal to 17 mg/L/mg/L, UV lamp power equal to 4 W, pH equal to 3 and treatment time of 180 min. It was found that the photo- Fenton process is very effective in treating synthetic textile wastewater, with a removal of 86 %, with respect to COD.
publishDate 2020
dc.date.none.fl_str_mv 2020-03-31
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Text
texto
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/273
10.37761/rsqp.v86i1.273
url http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/273
identifier_str_mv 10.37761/rsqp.v86i1.273
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/273/238
dc.rights.none.fl_str_mv Derechos de autor 2020 Sociedad Química del Perú
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2020 Sociedad Química del Perú
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv 2020
2020
dc.publisher.none.fl_str_mv Sociedad Química del Perú
publisher.none.fl_str_mv Sociedad Química del Perú
dc.source.none.fl_str_mv Revista de la Sociedad Química del Perú; Vol. 86 Núm. 1 (2020): Revista de la Sociedad Química del Perú; 58 - 69
Journal of the Chemical Society of Peru; Vol. 86 No. 1 (2020): Journal of Sociedad Química del Perú; 58 - 69
2309-8740
1810-634X
10.37761/rsqp.v86i1
reponame:Revista de la Sociedad Química del Perú
instname:Sociedad Química del Perú
instacron:SQP
instname_str Sociedad Química del Perú
instacron_str SQP
institution SQP
reponame_str Revista de la Sociedad Química del Perú
collection Revista de la Sociedad Química del Perú
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1846606543442673664
score 13.057984
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).