The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies

Descripción del Articulo

The simultaneous use of Au, Zr, Mo, Cr and Lu, for the characterization of irradiation facilities with the purpose of parametric neutron activation analysis, reveals some systematic inconsistencies in the determination of the values of the relevant parameters: thermal and epithermal fluxes, as well...

Descripción completa

Detalles Bibliográficos
Autores: Montoya, Eduardo, Mendoza, Pablo, Bedregal, Patricia, Ubillús, Marco, Torres, Blanca, Cohen, Isaac
Formato: artículo
Fecha de Publicación:2008
Institución:Instituto Peruano de Energía Nuclear
Repositorio:IPEN-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.ipen.gob.pe:20.500.13054/527
Enlace del recurso:https://hdl.handle.net/20.500.13054/527
Nivel de acceso:acceso abierto
Materia:Análisis por activación neutrónica
Flujo de neutrones
Neutrones epitérmicos
Reacciones de circonio 96
Reacciones de molibdeno 98
id IPEN_d7456112b4408603525834de712858f1
oai_identifier_str oai:repositorio.ipen.gob.pe:20.500.13054/527
network_acronym_str IPEN
network_name_str IPEN-Institucional
repository_id_str 3248
spelling Montoya, EduardoMendoza, PabloBedregal, PatriciaUbillús, MarcoTorres, BlancaCohen, IsaacMendoza, PabloCohen, IsaacTorres, BlancaUbillús, MarcoBedregal, PatriciaMontoya, Eduardo2015-12-04T17:01:13Z2015-12-04T17:01:13Z2008-11Montoya E, Mendoza P, Bedregal P, et al. The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies. Informe Científico Tecnológico. Volumen 7 (2007) p. 15-19.1684-1662https://hdl.handle.net/20.500.13054/527The simultaneous use of Au, Zr, Mo, Cr and Lu, for the characterization of irradiation facilities with the purpose of parametric neutron activation analysis, reveals some systematic inconsistencies in the determination of the values of the relevant parameters: thermal and epithermal fluxes, as well as the exponent alpha (α), which describes the non ideal behaviour of the epithermal neutron flux. An experimental case is presented, showing that when the determined values are optimal for the reaction 96Zr(n,ɣ)97Zr, can be unacceptably discrepant for the reactions 98Mo(n,ɣ)99Mo and 50Cr(n,ɣ)51Cr, and vice versa. Under the conditions of this work, it has been found that the pair of reactions 96Zr(n,ɣ)97Zr and 98Mo(n,ɣ)99Mo does not lead to a single solution for the values of the thermal and epithermal neutron fluxes, independently of the values given for the parameter α.El uso simultáneo de Au, Zr, Mo, Cr y Lu, para la caracterización de facilidades de irradiación, con propósitos de análisis por activación neutrónica paramétrico, revela algunas inconsistencias sistemáticas en la determinación de los parámetros relevantes: flujos térmico y epitérmico, así como el exponente alfa (α), que describe el comportamiento no ideal del flujo neutrónico epitérmico. Se presenta un caso experimental que muestra que cuando los valores determinados son óptimos para la reacción 96Zr(n,ɣ)97Zr, pueden ser inaceptablemente discrepantes para las reacciones 98Mo(n,ɣ)99Mo y 50Cr(n,ɣ)51Cr y viceversa. En las condiciones empleadas en este trabajo, se ha encontrado que el par de reacciones 96Zr(n,ɣ)97Zr y 98Mo(n,ɣ)99Mo no produce una solución única para los valores de los flujos neutrónicos térmico y epitérmico, independientemente de los valores que se asignen al parámetro α.Instituto Peruano de Energía Nuclearapplication/pdfengLima (Perú)PEinfo:eu-repo/semantics/openAccessInstituto Peruano de Energía NuclearRepositorio Institucional del Instituto Peruano de Energía Nuclearreponame:IPEN-Institucionalinstname:Instituto Peruano de Energía Nuclearinstacron:IPENAnálisis por activación neutrónicaFlujo de neutronesNeutrones epitérmicosReacciones de circonio 96Reacciones de molibdeno 98The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistenciesinfo:eu-repo/semantics/articleORIGINALPag 15-19 ICT-2007.pdfPag 15-19 ICT-2007.pdfapplication/pdf81113https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/1/Pag%2015-19%20ICT-2007.pdfcaec64f5fd29c33bcbaf99cbbf6fdc15MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-8103https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/2/license.txt7ecf7b0639239de61a3a1ede9c397fecMD52TEXTPag 15-19 ICT-2007.pdf.txtPag 15-19 ICT-2007.pdf.txtExtracted texttext/plain17123https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/3/Pag%2015-19%20ICT-2007.pdf.txtd9a85ea61fe952abe4703ed9469cc8d5MD53THUMBNAILPag 15-19 ICT-2007.pdf.jpgPag 15-19 ICT-2007.pdf.jpgGenerated Thumbnailimage/jpeg23513https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/4/Pag%2015-19%20ICT-2007.pdf.jpg7e5ab8a25c7b78545f7373834e397bdfMD5420.500.13054/527oai:repositorio.ipen.gob.pe:20.500.13054/5272022-02-07 18:05:54.054Repositorio Institucional del Instituto Peruano de Energía Nuclearrepositorio@ipen.gob.peU2UgRGlzdHJpYnV5ZSBiYWpvIHVuYSBMaWNlbmNpYSBDcmVhdGl2ZSBDb21tb25zIEF0cmlidWNpw7NuLU5vQ29tZXJjaWFsLVNpbkRlcml2YXIgNC4wIEludGVybmFjaW9uYWwuCg==
dc.title.es_PE.fl_str_mv The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
title The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
spellingShingle The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
Montoya, Eduardo
Análisis por activación neutrónica
Flujo de neutrones
Neutrones epitérmicos
Reacciones de circonio 96
Reacciones de molibdeno 98
title_short The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
title_full The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
title_fullStr The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
title_full_unstemmed The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
title_sort The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
dc.creator.none.fl_str_mv Mendoza, Pablo
Cohen, Isaac
Torres, Blanca
Ubillús, Marco
Bedregal, Patricia
Montoya, Eduardo
author Montoya, Eduardo
author_facet Montoya, Eduardo
Mendoza, Pablo
Bedregal, Patricia
Ubillús, Marco
Torres, Blanca
Cohen, Isaac
author_role author
author2 Mendoza, Pablo
Bedregal, Patricia
Ubillús, Marco
Torres, Blanca
Cohen, Isaac
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Montoya, Eduardo
Mendoza, Pablo
Bedregal, Patricia
Ubillús, Marco
Torres, Blanca
Cohen, Isaac
dc.subject.es_PE.fl_str_mv Análisis por activación neutrónica
Flujo de neutrones
Neutrones epitérmicos
Reacciones de circonio 96
Reacciones de molibdeno 98
topic Análisis por activación neutrónica
Flujo de neutrones
Neutrones epitérmicos
Reacciones de circonio 96
Reacciones de molibdeno 98
description The simultaneous use of Au, Zr, Mo, Cr and Lu, for the characterization of irradiation facilities with the purpose of parametric neutron activation analysis, reveals some systematic inconsistencies in the determination of the values of the relevant parameters: thermal and epithermal fluxes, as well as the exponent alpha (α), which describes the non ideal behaviour of the epithermal neutron flux. An experimental case is presented, showing that when the determined values are optimal for the reaction 96Zr(n,ɣ)97Zr, can be unacceptably discrepant for the reactions 98Mo(n,ɣ)99Mo and 50Cr(n,ɣ)51Cr, and vice versa. Under the conditions of this work, it has been found that the pair of reactions 96Zr(n,ɣ)97Zr and 98Mo(n,ɣ)99Mo does not lead to a single solution for the values of the thermal and epithermal neutron fluxes, independently of the values given for the parameter α.
publishDate 2008
dc.date.accessioned.none.fl_str_mv 2015-12-04T17:01:13Z
dc.date.available.none.fl_str_mv 2015-12-04T17:01:13Z
dc.date.issued.fl_str_mv 2008-11
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.citation.es_PE.fl_str_mv Montoya E, Mendoza P, Bedregal P, et al. The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies. Informe Científico Tecnológico. Volumen 7 (2007) p. 15-19.
dc.identifier.issn.none.fl_str_mv 1684-1662
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.13054/527
identifier_str_mv Montoya E, Mendoza P, Bedregal P, et al. The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies. Informe Científico Tecnológico. Volumen 7 (2007) p. 15-19.
1684-1662
url https://hdl.handle.net/20.500.13054/527
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Lima (Perú)
dc.publisher.country.es_PE.fl_str_mv PE
dc.source.es_PE.fl_str_mv Instituto Peruano de Energía Nuclear
Repositorio Institucional del Instituto Peruano de Energía Nuclear
dc.source.none.fl_str_mv reponame:IPEN-Institucional
instname:Instituto Peruano de Energía Nuclear
instacron:IPEN
instname_str Instituto Peruano de Energía Nuclear
instacron_str IPEN
institution IPEN
reponame_str IPEN-Institucional
collection IPEN-Institucional
bitstream.url.fl_str_mv https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/1/Pag%2015-19%20ICT-2007.pdf
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/2/license.txt
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/3/Pag%2015-19%20ICT-2007.pdf.txt
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/527/4/Pag%2015-19%20ICT-2007.pdf.jpg
bitstream.checksum.fl_str_mv caec64f5fd29c33bcbaf99cbbf6fdc15
7ecf7b0639239de61a3a1ede9c397fec
d9a85ea61fe952abe4703ed9469cc8d5
7e5ab8a25c7b78545f7373834e397bdf
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional del Instituto Peruano de Energía Nuclear
repository.mail.fl_str_mv repositorio@ipen.gob.pe
_version_ 1846785880682921984
score 12.825565
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).