Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa

Descripción del Articulo

El desarrollo de esta tesis fue posible debido al financiamiento recibido por el Fondo Nacional de Desarrollo Científico y de Innovación Tecnológica (FONDECYT) del Consejo Nacional de Ciencia y Tecnológica e Innovación Tecnológica (CONCYTEC) por medio del convenio de financiación Nº 024-2016....

Descripción completa

Detalles Bibliográficos
Autor: Castro Cuba Checya, Pio Roque
Formato: tesis de grado
Fecha de Publicación:2018
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/1675
Enlace del recurso:https://hdl.handle.net/20.500.12390/1675
Nivel de acceso:acceso abierto
Materia:Termo tanque
Piso radiante
Colectores solares
Calefacción solar
https://purl.org/pe-repo/ocde/ford#2.03.03
id CONC_4522b632f2f512cc71ac50a658c62a2d
oai_identifier_str oai:repositorio.concytec.gob.pe:20.500.12390/1675
network_acronym_str CONC
network_name_str CONCYTEC-Institucional
repository_id_str 4689
dc.title.none.fl_str_mv Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
title Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
spellingShingle Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
Castro Cuba Checya, Pio Roque
Termo tanque
Piso radiante
Colectores solares
Calefacción solar
https://purl.org/pe-repo/ocde/ford#2.03.03
title_short Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
title_full Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
title_fullStr Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
title_full_unstemmed Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
title_sort Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa
author Castro Cuba Checya, Pio Roque
author_facet Castro Cuba Checya, Pio Roque
author_role author
dc.contributor.author.fl_str_mv Castro Cuba Checya, Pio Roque
dc.subject.none.fl_str_mv Termo tanque
topic Termo tanque
Piso radiante
Colectores solares
Calefacción solar
https://purl.org/pe-repo/ocde/ford#2.03.03
dc.subject.es_PE.fl_str_mv Piso radiante
Colectores solares
Calefacción solar
dc.subject.ocde.none.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.03.03
description El desarrollo de esta tesis fue posible debido al financiamiento recibido por el Fondo Nacional de Desarrollo Científico y de Innovación Tecnológica (FONDECYT) del Consejo Nacional de Ciencia y Tecnológica e Innovación Tecnológica (CONCYTEC) por medio del convenio de financiación Nº 024-2016.
publishDate 2018
dc.date.accessioned.none.fl_str_mv 2024-05-30T23:13:38Z
dc.date.available.none.fl_str_mv 2024-05-30T23:13:38Z
dc.date.issued.fl_str_mv 2018
dc.type.none.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12390/1675
url https://hdl.handle.net/20.500.12390/1675
dc.language.iso.none.fl_str_mv spa
language spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.none.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.publisher.none.fl_str_mv Universidad Nacional de San Agustín de Arequipa
publisher.none.fl_str_mv Universidad Nacional de San Agustín de Arequipa
dc.source.none.fl_str_mv reponame:CONCYTEC-Institucional
instname:Consejo Nacional de Ciencia Tecnología e Innovación
instacron:CONCYTEC
instname_str Consejo Nacional de Ciencia Tecnología e Innovación
instacron_str CONCYTEC
institution CONCYTEC
reponame_str CONCYTEC-Institucional
collection CONCYTEC-Institucional
repository.name.fl_str_mv Repositorio Institucional CONCYTEC
repository.mail.fl_str_mv repositorio@concytec.gob.pe
_version_ 1844883047347912704
spelling Publicationrp04568600Castro Cuba Checya, Pio Roque2024-05-30T23:13:38Z2024-05-30T23:13:38Z2018https://hdl.handle.net/20.500.12390/1675El desarrollo de esta tesis fue posible debido al financiamiento recibido por el Fondo Nacional de Desarrollo Científico y de Innovación Tecnológica (FONDECYT) del Consejo Nacional de Ciencia y Tecnológica e Innovación Tecnológica (CONCYTEC) por medio del convenio de financiación Nº 024-2016.In the present work the evaluation and simulation of a heating system by radiant floor installedin the shelter of the town of Imata was carried out this with the purpose of knowing theenergetic contribution of the collectors to the thermo-tank as well as to the radiant floor, andat the same time perform the simulation for the behavior of the temperature on the floorsurface and its effect on the temperature inside the enclosure.The calculation of the energy delivered by the collectors to the tank and radiant floor has beenexperimentally determined. For the first evaluation, a value of 72,83 kWh was obtained forthe collectors, 36,08 kWh for the radiant floor and 12,98 kWh for the thermo-tank; for thesecond evaluation, which evaluated only the radiant floor, 80,77 kWh of energy used by thecollectors and 63,68 kWh delivered to the radiant floor were obtained; for the third evaluation,which also evaluated only the radiant floor, 71,29 kWh of energy used by the collectors and50,55 kWh delivered to the floor were obtained, of these quantities has that in the course ofthe collectors either to the thermo-tank or radiant floor there is considerable loss of energy .The simulation that takes into account the properties of the building materials of the sheltershow curves of surface temperature and temperature of the interior of the shelter that onlytakes into account the energy input of the radiant floor, is not included for the simulation thecontribution of external loads.We found the energy transmitted by the radiant floor during the night or while the heatingsystem does not work where it was obtained value of 37 kWh and 27 kWh for the nights ofJuly 30 and 31 respectively, the energy delivered to the floor the next day is 29 kWh and 18kWh (July 31 and August 1) so that the radiant floor installed in the Imata Shelter does notprovide the energy it lost during the night of July 30 and 31, It is missing 8 kWh and 9 kWhrespectively to compensate for the energy it transmitted , however the temperature inside theshelter is at maximum average around 18 ° C on the day this is 7 ° C more, compared to thetemperature outside, which is thermally pleasant for residents of the shelter.Fondo Nacional de Desarrollo Científico y Tecnológico - FondecytspaUniversidad Nacional de San Agustín de Arequipainfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/4.0/Termo tanquePiso radiante-1Colectores solares-1Calefacción solar-1https://purl.org/pe-repo/ocde/ford#2.03.03-1Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipainfo:eu-repo/semantics/bachelorThesisreponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/1675oai:repositorio.concytec.gob.pe:20.500.12390/16752024-05-30 16:04:40.556https://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="53e66842-030f-428b-ae2a-ff66a653d64c"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>spa</Language> <Title>Evaluación y simulación de un piso radiante en el albergue del centro poblado de Imata ubicado a 4500 msnm en el Departamento de Arequipa</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2018</PublicationDate> <Authors> <Author> <DisplayName>Castro Cuba Checya, Pio Roque</DisplayName> <Person id="rp04568" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Universidad Nacional de San Agustín de Arequipa</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nc-nd/4.0/</License> <Keyword>Termo tanque</Keyword> <Keyword>Piso radiante</Keyword> <Keyword>Colectores solares</Keyword> <Keyword>Calefacción solar</Keyword> <Abstract>In the present work the evaluation and simulation of a heating system by radiant floor installedin the shelter of the town of Imata was carried out this with the purpose of knowing theenergetic contribution of the collectors to the thermo-tank as well as to the radiant floor, andat the same time perform the simulation for the behavior of the temperature on the floorsurface and its effect on the temperature inside the enclosure.The calculation of the energy delivered by the collectors to the tank and radiant floor has beenexperimentally determined. For the first evaluation, a value of 72,83 kWh was obtained forthe collectors, 36,08 kWh for the radiant floor and 12,98 kWh for the thermo-tank; for thesecond evaluation, which evaluated only the radiant floor, 80,77 kWh of energy used by thecollectors and 63,68 kWh delivered to the radiant floor were obtained; for the third evaluation,which also evaluated only the radiant floor, 71,29 kWh of energy used by the collectors and50,55 kWh delivered to the floor were obtained, of these quantities has that in the course ofthe collectors either to the thermo-tank or radiant floor there is considerable loss of energy .The simulation that takes into account the properties of the building materials of the sheltershow curves of surface temperature and temperature of the interior of the shelter that onlytakes into account the energy input of the radiant floor, is not included for the simulation thecontribution of external loads.We found the energy transmitted by the radiant floor during the night or while the heatingsystem does not work where it was obtained value of 37 kWh and 27 kWh for the nights ofJuly 30 and 31 respectively, the energy delivered to the floor the next day is 29 kWh and 18kWh (July 31 and August 1) so that the radiant floor installed in the Imata Shelter does notprovide the energy it lost during the night of July 30 and 31, It is missing 8 kWh and 9 kWhrespectively to compensate for the energy it transmitted , however the temperature inside theshelter is at maximum average around 18 ° C on the day this is 7 ° C more, compared to thetemperature outside, which is thermally pleasant for residents of the shelter.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1
score 13.422088
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).