Supervision, control, and data acquisition system of a heat exchanger
Descripción del Articulo
Today, when industry 4.0 is already being talked about, and its advantages at the organizational level, there are still industrial processes that show a lack of automatic regulation mechanisms, which means that an optimal operating process is not guaranteed, nor that monitoring and supervision capac...
Autores: | , , , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2022 |
Institución: | Universidad Autónoma del Perú |
Repositorio: | AUTONOMA-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.autonoma.edu.pe:20.500.13067/2609 |
Enlace del recurso: | https://hdl.handle.net/20.500.13067/2609 https://doi.org/10.11591/ijeecs.v28.i1.pp155-164 |
Nivel de acceso: | acceso abierto |
Materia: | Automation Concentric tubes Data acquisition Heat exchanger Monitoring https://purl.org/pe-repo/ocde/ford#2.02.04 |
Sumario: | Today, when industry 4.0 is already being talked about, and its advantages at the organizational level, there are still industrial processes that show a lack of automatic regulation mechanisms, which means that an optimal operating process is not guaranteed, nor that monitoring and supervision capacity. In this sense, the purpose of the article is to demonstrate the feasibility of the integration between the programmable logic controller and the Arduino nanocontrollers, this as an alternative to automate a concentric tube heat exchanger, for monitoring and data acquisition through a supervision, control and data acquisition system. The integration is shown through the design and implementation of a temperature transducer made up of a MAX6675 converter module and an Arduino Nano controller, which is amplified through its pulse width modulation (PWM) interface and the integrated TL081CP and coupled to the analog inputs of the automaton. As a result of the experimental tests, it was possible to determine that the flow rate of the automated system is directly proportional to the drop or difference in temperature in the hot fluid and inversely proportional to the increase in temperature in the cold fluid, verifying the effectiveness of the automated heat exchanger. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).