Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo

Descripción del Articulo

OBJECTIVE: To detect ocular hypertension with the Goldmann tonometer against the pneumotometer in adult outpatients, at the Regional Institute of Ophthalmology-JSU -Trujillo 2019. MATERIAL AND METHODS: In a sample of 200 eyes of 100 patients, who go to an external ophthalmology office, who meet the...

Descripción completa

Detalles Bibliográficos
Autor: Palma Pinedo, Práxedes Jesús
Formato: otro
Fecha de Publicación:2019
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/13280
Enlace del recurso:https://hdl.handle.net/20.500.14414/13280
Nivel de acceso:acceso abierto
Materia:Neumotonómetro
Tonometría de Goldmann
Presión intraocular
Espesor corneal central
id UNIT_c05d96e2b50321fcf97ac18e28d06dd5
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/13280
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_PE.fl_str_mv Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
title Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
spellingShingle Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
Palma Pinedo, Práxedes Jesús
Neumotonómetro
Tonometría de Goldmann
Presión intraocular
Espesor corneal central
title_short Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
title_full Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
title_fullStr Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
title_full_unstemmed Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
title_sort Detección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujillo
author Palma Pinedo, Práxedes Jesús
author_facet Palma Pinedo, Práxedes Jesús
author_role author
dc.contributor.advisor.fl_str_mv Rioja García, Miguel Eduardo
dc.contributor.author.fl_str_mv Palma Pinedo, Práxedes Jesús
dc.subject.es_PE.fl_str_mv Neumotonómetro
Tonometría de Goldmann
Presión intraocular
Espesor corneal central
topic Neumotonómetro
Tonometría de Goldmann
Presión intraocular
Espesor corneal central
description OBJECTIVE: To detect ocular hypertension with the Goldmann tonometer against the pneumotometer in adult outpatients, at the Regional Institute of Ophthalmology-JSU -Trujillo 2019. MATERIAL AND METHODS: In a sample of 200 eyes of 100 patients, who go to an external ophthalmology office, who meet the inclusion criteria; The nursing staff takes the intraocular pressure with the pneumotometer (NIDEK NT-510) in both eyes. This information is written on the data collection sheet; Subsequently, the intraocular pressure is taken with the Goldmann tonometer performed by an assistant ophthalmologist, whose data is written on the data collection sheet. The central corneal thickness of the patient is also calculated with the corneal pachymeter. RESULTS: IOP> 21, of the right eye, is obtained in 67 patients with T. Goldmann as well as with the pneumotometer. In the left eye, with IOP> 21, it is detected with NT in 79 patients, compared with 76 patients taken with TG. Of the total patients in the study, 36% were male and 64% were female. In the distribution by the age range, it was obtained that the highest percentage was constituted by the range between 60 to 69 years, with 36%, then the range between 70 to 79 years with 33% and finally 21 % of patients were in the range between 50 to 59 years. In our study we also detected 26 right eyes and 26 left eyes of patients with thickness corneal central in the range considered normal in our study. Sensitivity in the pneumotometer was 100%, The specificity in the pneumotometer was 100%. The Positive Predictive Value was 33% and the Negative Predictive Value was 79%. CONCLUSIONS: In our study the detection of ocular hypertension with Pneumotometer is as effective as the Goldmann tonometer (applanation tonometry), in adult outpatients, at the Regional Institute of Ophthalmology-JSU, Trujillo, 2019.
publishDate 2019
dc.date.accessioned.none.fl_str_mv 2019-08-06T17:11:25Z
dc.date.available.none.fl_str_mv 2019-08-06T17:11:25Z
dc.date.issued.fl_str_mv 2019-08-06
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/other
format other
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/13280
url https://hdl.handle.net/20.500.14414/13280
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.es_PE.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_PE.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/a5176a81-f15d-44b9-9a43-91d0d21a45b4/download
https://dspace.unitru.edu.pe/bitstreams/ae76efb4-e88b-4332-b767-36e69d7f65a8/download
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
2b11f9056a77f4c6543a0cd84679a225
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290196547338240
spelling Rioja García, Miguel EduardoPalma Pinedo, Práxedes Jesús2019-08-06T17:11:25Z2019-08-06T17:11:25Z2019-08-06https://hdl.handle.net/20.500.14414/13280OBJECTIVE: To detect ocular hypertension with the Goldmann tonometer against the pneumotometer in adult outpatients, at the Regional Institute of Ophthalmology-JSU -Trujillo 2019. MATERIAL AND METHODS: In a sample of 200 eyes of 100 patients, who go to an external ophthalmology office, who meet the inclusion criteria; The nursing staff takes the intraocular pressure with the pneumotometer (NIDEK NT-510) in both eyes. This information is written on the data collection sheet; Subsequently, the intraocular pressure is taken with the Goldmann tonometer performed by an assistant ophthalmologist, whose data is written on the data collection sheet. The central corneal thickness of the patient is also calculated with the corneal pachymeter. RESULTS: IOP> 21, of the right eye, is obtained in 67 patients with T. Goldmann as well as with the pneumotometer. In the left eye, with IOP> 21, it is detected with NT in 79 patients, compared with 76 patients taken with TG. Of the total patients in the study, 36% were male and 64% were female. In the distribution by the age range, it was obtained that the highest percentage was constituted by the range between 60 to 69 years, with 36%, then the range between 70 to 79 years with 33% and finally 21 % of patients were in the range between 50 to 59 years. In our study we also detected 26 right eyes and 26 left eyes of patients with thickness corneal central in the range considered normal in our study. Sensitivity in the pneumotometer was 100%, The specificity in the pneumotometer was 100%. The Positive Predictive Value was 33% and the Negative Predictive Value was 79%. CONCLUSIONS: In our study the detection of ocular hypertension with Pneumotometer is as effective as the Goldmann tonometer (applanation tonometry), in adult outpatients, at the Regional Institute of Ophthalmology-JSU, Trujillo, 2019.OBJETIVO: Detectar hipertensión ocular con el tonómetro de Goldmann frente al neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología-JSU -Trujillo 2019. MATERIAL Y MÉTODOS:En una muestra de 200 ojos de 100 pacientes, que acuden a consulta externa de oftalmología, que cumplen los criterios de inclusión; el personal técnico de enfermería realiza la toma de la presión intraocular con el neumotonómetro (NIDEK NT-510) en ambos ojos, dicha información se escribe en la ficha de recolección de datos; posteriormente se realiza la toma de presión intraocular con el tonómetro de Goldmann efectuada por un oftalmólogo asistente, cuyos datos se escriben en la ficha de recolección de datos. Se procede también a calcular el grosor corneal central del paciente con el paquímetro corneal. RESULTADOS: Se obtiene PIO>21, de ojo derecho, en 67 pacientes con el T. Goldmann así como también con el neumotonómetro. En ojo izquierdo , con PIO > 21 se detecta con el NT en 79 pacientes, en comparación con 76 pacientes tomados con el TG. Del total de pacientes del estudio, el 36% fueron del sexo masculino y el 64% fueron del sexo femenino. En la distribución por el rango de edades, se obtuvo que el mayor porcentaje estuvo constituido por el rango comprendido entre los 60 a 69 años, con 36%, a continuación, el rango entre los 70 a 79 años con el 33% y finalmente 21% de los pacientes estuvo en el rango entre 50 a 59 años. En nuestro estudio detectamos también 26 ojos derechos y 26 ojos izquierdos de pacientes con ECC en el rango considerado normal de nuestro estudio. Sensibilidad en el neumotonómetro fue del 100%, La especificidad en el neumotonómetro fue del 100%. El Valor Predictivo positivo fue 33% y el Valor predictivo negativo fue de 79%. CONCLUSIONES: En nuestro estudio la detección de hipertensión ocular con Neumotonómetro es tan efectiva como el tonómetro de Goldmann (tonometría de aplanación), en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología-JSU, Trujillo, 2019Trabajo de investigaciónspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUNeumotonómetroTonometría de GoldmannPresión intraocularEspesor corneal centralDetección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujilloinfo:eu-repo/semantics/otherTítulo de Segunda EspecialidadOftalmólogoOftalmologíaUniversidad Nacional de Trujillo.Facultad de MedicinaLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/a5176a81-f15d-44b9-9a43-91d0d21a45b4/download8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALPalmaPinedo_P.pdfPalmaPinedo_P.pdfDetección de hipertensión ocular con tonómetro de Goldmann frente al Neumotonómetro en pacientes adultos de consulta externa, en el Instituto Regional de Oftalmología JSU- Trujilloapplication/pdf1354110https://dspace.unitru.edu.pe/bitstreams/ae76efb4-e88b-4332-b767-36e69d7f65a8/download2b11f9056a77f4c6543a0cd84679a225MD5320.500.14414/13280oai:dspace.unitru.edu.pe:20.500.14414/132802019-11-04 15:02:56.481http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.959968
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).