Influencia de la granulometría y tipo de concentrador en la recuperación y ley de oro mediante gravimetría

Descripción del Articulo

The variables of influence of particle size (percentage passing 200 mesh) and type of gravimetric concentrator on gold recovery (%) and gold grade (g/t) were investigated using a composite sample of three ores from the Pataz area, with the following chemical composition: 6.47 g/t Au and 16.26 g/t Ag...

Descripción completa

Detalles Bibliográficos
Autores: Iglesias Carrasco, Maicol Arnold, Mauricio Pérez, Cristhian Jhonatan
Formato: tesis de grado
Fecha de Publicación:2023
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/16401
Enlace del recurso:https://hdl.handle.net/20.500.14414/16401
Nivel de acceso:acceso abierto
Materia:Influencia de la granulometría y tipo de concentrador
Descripción
Sumario:The variables of influence of particle size (percentage passing 200 mesh) and type of gravimetric concentrator on gold recovery (%) and gold grade (g/t) were investigated using a composite sample of three ores from the Pataz area, with the following chemical composition: 6.47 g/t Au and 16.26 g/t Ag. A bifactorial design was used, with the variable granulometry evaluated at levels 35, 45 and 55 % passing through 200 mesh and the type of concentrator: Wilfley type gravity table and Icon i150 centrifugal concentrator, the dependent variable being the percentage of gold recovery and the gold grade (g/t). Concentrate was obtained with gravimetric table at 35% - #200, gold recovery 67.70 % and grade of 9.94 g/t, at 45% - #200, gold recovery 63.16 % and grade of 12.45 g/t, at 55% - #200, gold recovery 56.12 % and grade of 17.84 g/t. With centrifugal concentrator was obtained at 35% - #200, gold recovery 24.70 % and grade of 24.24 g/t, at 45% - #200, gold recovery 38.60 % and grade of 35.68 g/t, at 55% - #200, gold recovery 47.30 % and grade of 42.19 g/t. According to the results, for the analysis of variance for gold recovery and gold grade, P=0.000 was obtained for the particle size, P=0.000 for the type of gravimetric concentrator, and P=0.000 for the interaction of both variables, it can be concluded that the particle size (% passing 200 mesh) and type of gravimetric concentrator significantly influence gold recovery and gold grade.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).