Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo
Descripción del Articulo
The present study was carried out with the objective of determining if the high values of pulse oximetry (> 90%) constitute a risk factor for retinopathy of prematurity (ROP) in neonates of the Neonatology service of the Belén de Trujillo Hospital. For this purpose, a retrospective analytical stu...
| Autor: | |
|---|---|
| Formato: | tesis de grado |
| Fecha de Publicación: | 2018 |
| Institución: | Universidad Nacional de Trujillo |
| Repositorio: | UNITRU-Tesis |
| Lenguaje: | español |
| OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/9958 |
| Enlace del recurso: | https://hdl.handle.net/20.500.14414/9958 |
| Nivel de acceso: | acceso abierto |
| Materia: | Oximetría de pulso, Retinopatía de la prematuridad, Edad gestacional |
| id |
UNIT_b28f6d27c7465f51778b5e38739fc4df |
|---|---|
| oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/9958 |
| network_acronym_str |
UNIT |
| network_name_str |
UNITRU-Tesis |
| repository_id_str |
4801 |
| dc.title.es_PE.fl_str_mv |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| title |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| spellingShingle |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo Marreros Aquino, Nicole Mayumy Oximetría de pulso, Retinopatía de la prematuridad, Edad gestacional |
| title_short |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| title_full |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| title_fullStr |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| title_full_unstemmed |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| title_sort |
Valores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujillo |
| author |
Marreros Aquino, Nicole Mayumy |
| author_facet |
Marreros Aquino, Nicole Mayumy |
| author_role |
author |
| dc.contributor.advisor.fl_str_mv |
Manrique Ganoza, Alberto Hermas |
| dc.contributor.author.fl_str_mv |
Marreros Aquino, Nicole Mayumy |
| dc.subject.es_PE.fl_str_mv |
Oximetría de pulso, Retinopatía de la prematuridad, Edad gestacional |
| topic |
Oximetría de pulso, Retinopatía de la prematuridad, Edad gestacional |
| description |
The present study was carried out with the objective of determining if the high values of pulse oximetry (> 90%) constitute a risk factor for retinopathy of prematurity (ROP) in neonates of the Neonatology service of the Belén de Trujillo Hospital. For this purpose, a retrospective analytical study of cases and controls was carried out, with a population of 104 neonates with less than 1500 g of birthweight and less than 32 weeks of gestational age registered between the 2012-2017 period; divided into 2 groups: with ROP and without it; the odds ratio and the chi square test were calculated. Obtaining that the averages of gestational age and birth weight were significantly lower in the group with ROP than in the group without ROP. The frequency of high pulse oximetry values in neonates with ROP was 52%, while 25% in those without ROP (p <0.05). It should be noted that there were significant differences between both population samples in terms of gestational age and birth weight, so that the variables in question could be considered confusing, in addition, other possible intervening variables were not considered. Nevertheless; Corroborate that high values of pulse oximetry are a risk factor for ROP |
| publishDate |
2018 |
| dc.date.accessioned.none.fl_str_mv |
2018-03-12T16:06:16Z |
| dc.date.available.none.fl_str_mv |
2018-03-12T16:06:16Z |
| dc.date.issued.fl_str_mv |
2018 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
| format |
bachelorThesis |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/9958 |
| url |
https://hdl.handle.net/20.500.14414/9958 |
| dc.language.iso.es_PE.fl_str_mv |
spa |
| language |
spa |
| dc.relation.ispartof.fl_str_mv |
SUNEDU |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
| dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
| dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
| dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
| instname_str |
Universidad Nacional de Trujillo |
| instacron_str |
UNITRU |
| institution |
UNITRU |
| reponame_str |
UNITRU-Tesis |
| collection |
UNITRU-Tesis |
| bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/19797f94-d1ea-4587-bf82-e8a1d44c9df4/download https://dspace.unitru.edu.pe/bitstreams/9637d343-5ffb-4e26-82ff-0debf705792a/download |
| bitstream.checksum.fl_str_mv |
570bc3c916666bd699db20396d2a9f19 8a4605be74aa9ea9d79846c1fba20a33 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
| repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
| _version_ |
1807289809649008640 |
| spelling |
Manrique Ganoza, Alberto HermasMarreros Aquino, Nicole Mayumy2018-03-12T16:06:16Z2018-03-12T16:06:16Z2018https://hdl.handle.net/20.500.14414/9958The present study was carried out with the objective of determining if the high values of pulse oximetry (> 90%) constitute a risk factor for retinopathy of prematurity (ROP) in neonates of the Neonatology service of the Belén de Trujillo Hospital. For this purpose, a retrospective analytical study of cases and controls was carried out, with a population of 104 neonates with less than 1500 g of birthweight and less than 32 weeks of gestational age registered between the 2012-2017 period; divided into 2 groups: with ROP and without it; the odds ratio and the chi square test were calculated. Obtaining that the averages of gestational age and birth weight were significantly lower in the group with ROP than in the group without ROP. The frequency of high pulse oximetry values in neonates with ROP was 52%, while 25% in those without ROP (p <0.05). It should be noted that there were significant differences between both population samples in terms of gestational age and birth weight, so that the variables in question could be considered confusing, in addition, other possible intervening variables were not considered. Nevertheless; Corroborate that high values of pulse oximetry are a risk factor for ROPEl presente estudio fue realizado con el objetivo de determinar si los valores elevados de la oximetría de pulso (> 90 %) constituyen factor de riesgo de retinopatía de la prematuridad (ROP) en neonatos del servicio de Neonatología del Hospital Belén de Trujillo. Para ello se llevó a cabo un estudio de tipo analítico, retrospectivo, de casos y controles, con un población de 104 neonatos con menos de 1500 g de peso al nacer ymenos de 32 semanas de edad gestacional registrados entre el periodo 2012- 2017; divididos en 2 grupos: con ROP y sin ella; se calculó el odds ratio y la prueba chi cuadrado. Obteniéndose que los promedios de edad gestacional y el peso al nacer fueron significativamente inferiores en el grupo con ROP que en el grupo sin ROP. La frecuencia de valores elevados de oximetría de pulso en neonatos que presentaron ROP fue de 52% mientras que 25% en los que no presentaron ROP (p< 0.05). Cabe señalar existieron diferencias significativas entre ambas muestras poblacionales en cuanto a edad gestacional y peso al nacer, de modo que las variables en cuestión se podrían considerar confusoras, además, no se consideraron otras posibles variables intervinientes. Sin embargo; se logra corroborar que los valores elevados de oximetría de pulso son factor de riesgo para ROPTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUOximetría de pulso, Retinopatía de la prematuridad, Edad gestacionalValores elevados de oximetría de pulso como factor de riesgo de retinopatía del prematuro en el Hospital Belén de Trujilloinfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalMédicoMedicinaUniversidad Nacional de Trujillo.Facultad de MedicinaORIGINALMarrerosAquino_N.pdfMarrerosAquino_N.pdfapplication/pdf806060https://dspace.unitru.edu.pe/bitstreams/19797f94-d1ea-4587-bf82-e8a1d44c9df4/download570bc3c916666bd699db20396d2a9f19MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/9637d343-5ffb-4e26-82ff-0debf705792a/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/9958oai:dspace.unitru.edu.pe:20.500.14414/99582018-03-12 11:06:16.726http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
| score |
13.905835 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).