Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli
Descripción del Articulo
The present work sought to guarantee the results obtained in the chemical laboratory Mahr Túnel de Volcan Compañía Minera S.A.A. U.E.A. Yauli by evaluating the validation parameters in a test method of said laboratory. The accuracy of the method was determined by the veracity and precision analysis...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2009 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/9173 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/9173 |
Nivel de acceso: | acceso abierto |
Materia: | Ácido nítrico, Ácido clorhídrico, Espectrofotometría de absorción atómica |
id |
UNIT_a5187661d8e4df5605e8f1f534cf4682 |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/9173 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_PE.fl_str_mv |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
title |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
spellingShingle |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli Alayo Rodríguez, Jorge Luis Ácido nítrico, Ácido clorhídrico, Espectrofotometría de absorción atómica |
title_short |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
title_full |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
title_fullStr |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
title_full_unstemmed |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
title_sort |
Evaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauli |
author |
Alayo Rodríguez, Jorge Luis |
author_facet |
Alayo Rodríguez, Jorge Luis Chávez Aliaga, Nélson |
author_role |
author |
author2 |
Chávez Aliaga, Nélson |
author2_role |
author |
dc.contributor.advisor.fl_str_mv |
Reyes Lázaro, Wilson |
dc.contributor.author.fl_str_mv |
Alayo Rodríguez, Jorge Luis Chávez Aliaga, Nélson |
dc.subject.es_PE.fl_str_mv |
Ácido nítrico, Ácido clorhídrico, Espectrofotometría de absorción atómica |
topic |
Ácido nítrico, Ácido clorhídrico, Espectrofotometría de absorción atómica |
description |
The present work sought to guarantee the results obtained in the chemical laboratory Mahr Túnel de Volcan Compañía Minera S.A.A. U.E.A. Yauli by evaluating the validation parameters in a test method of said laboratory. The accuracy of the method was determined by the veracity and precision analysis by the method of standard addition with sample, the selectivity by the method of "type I analysis: power, dissolution and uniformity of content - comparison of the behavior of samples enriched with analyte with respect to the standard behavior enriched with analyte ", the limit of detection by comparison of white and white enriched to a single concentration and the limit of quantification as 3 times the limit of detection, the linearity was determined by validating the calibration curve of the Perkin Elmer AAnalys 100 atomic absorption equipment; the sensitivity was the slope of the calibration curve, the robustness of the method was determined by means of the Youden and Steiner procedure taking as variables the addition of 5 to 10 mL of hydrochloric acid, addition of 5 to 10 mL of nitric acid and temperature of attack between 200 and 300 ºC; Finally, the uncertainty of the method was evaluated by calculating the expanded uncertainty. After the experimental development it was demonstrated that the studied method is accurate, selective, linear, robust; and the sensitivity of the Perkin Elmer AAnalys 100 atomic absorption equipment, the instrumental detection and quantification limits and the uncertainty as expanded uncertainty were determined |
publishDate |
2009 |
dc.date.accessioned.none.fl_str_mv |
2017-11-17T14:17:20Z |
dc.date.available.none.fl_str_mv |
2017-11-17T14:17:20Z |
dc.date.issued.fl_str_mv |
2009 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/9173 |
url |
https://hdl.handle.net/20.500.14414/9173 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/bb7bb21d-62da-4697-8e33-77ca99fd749e/download https://dspace.unitru.edu.pe/bitstreams/f0ab4052-698b-4465-84b1-197812bdf3a3/download |
bitstream.checksum.fl_str_mv |
8072b430057d4dfb0fb9240c07740a7b 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807290215065190400 |
spelling |
Reyes Lázaro, WilsonAlayo Rodríguez, Jorge LuisChávez Aliaga, Nélson2017-11-17T14:17:20Z2017-11-17T14:17:20Z2009https://hdl.handle.net/20.500.14414/9173The present work sought to guarantee the results obtained in the chemical laboratory Mahr Túnel de Volcan Compañía Minera S.A.A. U.E.A. Yauli by evaluating the validation parameters in a test method of said laboratory. The accuracy of the method was determined by the veracity and precision analysis by the method of standard addition with sample, the selectivity by the method of "type I analysis: power, dissolution and uniformity of content - comparison of the behavior of samples enriched with analyte with respect to the standard behavior enriched with analyte ", the limit of detection by comparison of white and white enriched to a single concentration and the limit of quantification as 3 times the limit of detection, the linearity was determined by validating the calibration curve of the Perkin Elmer AAnalys 100 atomic absorption equipment; the sensitivity was the slope of the calibration curve, the robustness of the method was determined by means of the Youden and Steiner procedure taking as variables the addition of 5 to 10 mL of hydrochloric acid, addition of 5 to 10 mL of nitric acid and temperature of attack between 200 and 300 ºC; Finally, the uncertainty of the method was evaluated by calculating the expanded uncertainty. After the experimental development it was demonstrated that the studied method is accurate, selective, linear, robust; and the sensitivity of the Perkin Elmer AAnalys 100 atomic absorption equipment, the instrumental detection and quantification limits and the uncertainty as expanded uncertainty were determinedEl presente trabajo buscó garantizar los resultados obtenidos en el laboratorio químico Mahr Túnel de Volcan Compañía Minera S.A.A. U.E.A. Yauli mediante la evaluación de los parámetros de validación en un método de ensayo de dicho laboratorio. Se determinó en el método, la exactitud mediante el análisis de veracidad y precisión por el método de adición estándar con muestra, la selectividad mediante el método de “análisis tipo I: potencia, disolución y uniformidad de contenido - comparación del comportamiento de muestras enriquecidas con analito con respecto al comportamiento de estándar enriquecido con analito”, el límite de detección por comparación de blanco y blanco enriquecido a una sola concentración y el limite de cuantificación como 3 veces el límite de detección, la linearidad se determinó validando la curva de calibración del equipo de absorción atómica Perkin Elmer AAnalys 100; la sensibilidad fue la pendiente de la curva de calibración, la robustez del método se determinó mediante el procedimiento de Youden y Steiner tomando como variables a la adición de 5 a 10 mL de ácido clorhídrico, adición de 5 a 10 mL de ácido nítrico y temperatura de ataque entre 200 y 300 ºC; finalmente se evaluó la incertidumbre del método mediante el cálculo de la incertidumbre expandida. Luego del desarrollo experimental se demostró que el método estudiado es exacto, selectivo, lineal, robusto; y se determinó la sensibilidad del equipo de absorción atómica Perkin Elmer AAnalys 100, los límites de detección y cuantificación instrumentales y la incertidumbre como incertidumbre expandidaTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUÁcido nítrico, Ácido clorhídrico, Espectrofotometría de absorción atómicaEvaluación de los parámetros de validación en el método para la determinación de cobre, plomo, zinc, fierro y plata por espectrofotometría de absorción atómica de flama en muestras de cabeza del laboratorio químico MAHR túnel de volcán compañía minera S.A.A. U.E.A. yauliinfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngeniero QuímicoIngeniería QuímicaUniversidad Nacional de Trujillo.Facultad de Ingeniería QuímicaORIGINALAlayoRodriguez_J - ChavezAliaga_N.pdfAlayoRodriguez_J - ChavezAliaga_N.pdfapplication/pdf7850598https://dspace.unitru.edu.pe/bitstreams/bb7bb21d-62da-4697-8e33-77ca99fd749e/download8072b430057d4dfb0fb9240c07740a7bMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/f0ab4052-698b-4465-84b1-197812bdf3a3/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/9173oai:dspace.unitru.edu.pe:20.500.14414/91732017-11-17 09:17:20.204http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.peTk9URTogUExBQ0UgWU9VUiBPV04gTElDRU5TRSBIRVJFClRoaXMgc2FtcGxlIGxpY2Vuc2UgaXMgcHJvdmlkZWQgZm9yIGluZm9ybWF0aW9uYWwgcHVycG9zZXMgb25seS4KCk5PTi1FWENMVVNJVkUgRElTVFJJQlVUSU9OIExJQ0VOU0UKCkJ5IHNpZ25pbmcgYW5kIHN1Ym1pdHRpbmcgdGhpcyBsaWNlbnNlLCB5b3UgKHRoZSBhdXRob3Iocykgb3IgY29weXJpZ2h0Cm93bmVyKSBncmFudHMgdG8gRFNwYWNlIFVuaXZlcnNpdHkgKERTVSkgdGhlIG5vbi1leGNsdXNpdmUgcmlnaHQgdG8gcmVwcm9kdWNlLAp0cmFuc2xhdGUgKGFzIGRlZmluZWQgYmVsb3cpLCBhbmQvb3IgZGlzdHJpYnV0ZSB5b3VyIHN1Ym1pc3Npb24gKGluY2x1ZGluZwp0aGUgYWJzdHJhY3QpIHdvcmxkd2lkZSBpbiBwcmludCBhbmQgZWxlY3Ryb25pYyBmb3JtYXQgYW5kIGluIGFueSBtZWRpdW0sCmluY2x1ZGluZyBidXQgbm90IGxpbWl0ZWQgdG8gYXVkaW8gb3IgdmlkZW8uCgpZb3UgYWdyZWUgdGhhdCBEU1UgbWF5LCB3aXRob3V0IGNoYW5naW5nIHRoZSBjb250ZW50LCB0cmFuc2xhdGUgdGhlCnN1Ym1pc3Npb24gdG8gYW55IG1lZGl1bSBvciBmb3JtYXQgZm9yIHRoZSBwdXJwb3NlIG9mIHByZXNlcnZhdGlvbi4KCllvdSBhbHNvIGFncmVlIHRoYXQgRFNVIG1heSBrZWVwIG1vcmUgdGhhbiBvbmUgY29weSBvZiB0aGlzIHN1Ym1pc3Npb24gZm9yCnB1cnBvc2VzIG9mIHNlY3VyaXR5LCBiYWNrLXVwIGFuZCBwcmVzZXJ2YXRpb24uCgpZb3UgcmVwcmVzZW50IHRoYXQgdGhlIHN1Ym1pc3Npb24gaXMgeW91ciBvcmlnaW5hbCB3b3JrLCBhbmQgdGhhdCB5b3UgaGF2ZQp0aGUgcmlnaHQgdG8gZ3JhbnQgdGhlIHJpZ2h0cyBjb250YWluZWQgaW4gdGhpcyBsaWNlbnNlLiBZb3UgYWxzbyByZXByZXNlbnQKdGhhdCB5b3VyIHN1Ym1pc3Npb24gZG9lcyBub3QsIHRvIHRoZSBiZXN0IG9mIHlvdXIga25vd2xlZGdlLCBpbmZyaW5nZSB1cG9uCmFueW9uZSdzIGNvcHlyaWdodC4KCklmIHRoZSBzdWJtaXNzaW9uIGNvbnRhaW5zIG1hdGVyaWFsIGZvciB3aGljaCB5b3UgZG8gbm90IGhvbGQgY29weXJpZ2h0LAp5b3UgcmVwcmVzZW50IHRoYXQgeW91IGhhdmUgb2J0YWluZWQgdGhlIHVucmVzdHJpY3RlZCBwZXJtaXNzaW9uIG9mIHRoZQpjb3B5cmlnaHQgb3duZXIgdG8gZ3JhbnQgRFNVIHRoZSByaWdodHMgcmVxdWlyZWQgYnkgdGhpcyBsaWNlbnNlLCBhbmQgdGhhdApzdWNoIHRoaXJkLXBhcnR5IG93bmVkIG1hdGVyaWFsIGlzIGNsZWFybHkgaWRlbnRpZmllZCBhbmQgYWNrbm93bGVkZ2VkCndpdGhpbiB0aGUgdGV4dCBvciBjb250ZW50IG9mIHRoZSBzdWJtaXNzaW9uLgoKSUYgVEhFIFNVQk1JU1NJT04gSVMgQkFTRUQgVVBPTiBXT1JLIFRIQVQgSEFTIEJFRU4gU1BPTlNPUkVEIE9SIFNVUFBPUlRFRApCWSBBTiBBR0VOQ1kgT1IgT1JHQU5JWkFUSU9OIE9USEVSIFRIQU4gRFNVLCBZT1UgUkVQUkVTRU5UIFRIQVQgWU9VIEhBVkUKRlVMRklMTEVEIEFOWSBSSUdIVCBPRiBSRVZJRVcgT1IgT1RIRVIgT0JMSUdBVElPTlMgUkVRVUlSRUQgQlkgU1VDSApDT05UUkFDVCBPUiBBR1JFRU1FTlQuCgpEU1Ugd2lsbCBjbGVhcmx5IGlkZW50aWZ5IHlvdXIgbmFtZShzKSBhcyB0aGUgYXV0aG9yKHMpIG9yIG93bmVyKHMpIG9mIHRoZQpzdWJtaXNzaW9uLCBhbmQgd2lsbCBub3QgbWFrZSBhbnkgYWx0ZXJhdGlvbiwgb3RoZXIgdGhhbiBhcyBhbGxvd2VkIGJ5IHRoaXMKbGljZW5zZSwgdG8geW91ciBzdWJtaXNzaW9uLgo= |
score |
13.774068 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).