Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico

Descripción del Articulo

As the cutting regime and tool geometry on surface roughness influence the turning of the Co-28Cr-6Mo alloys used as biomaterials was investigated. The purpose was to recommend optimum machining conditions that produce standardized roughness in biomedical implants. The study material was acquired as...

Descripción completa

Detalles Bibliográficos
Autor: Castro Zavaleta, Santos Homero
Formato: tesis de grado
Fecha de Publicación:2017
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/9385
Enlace del recurso:https://hdl.handle.net/20.500.14414/9385
Nivel de acceso:acceso abierto
Materia:Rugosidad superficial, Torneado de aleaciones
id UNIT_4af28debe283c4511e1859f9187c9b87
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/9385
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_PE.fl_str_mv Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
title Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
spellingShingle Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
Castro Zavaleta, Santos Homero
Rugosidad superficial, Torneado de aleaciones
title_short Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
title_full Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
title_fullStr Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
title_full_unstemmed Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
title_sort Efectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédico
author Castro Zavaleta, Santos Homero
author_facet Castro Zavaleta, Santos Homero
author_role author
dc.contributor.advisor.fl_str_mv Alcántara Alza, Víctor Manuel
dc.contributor.author.fl_str_mv Castro Zavaleta, Santos Homero
dc.subject.es_PE.fl_str_mv Rugosidad superficial, Torneado de aleaciones
topic Rugosidad superficial, Torneado de aleaciones
description As the cutting regime and tool geometry on surface roughness influence the turning of the Co-28Cr-6Mo alloys used as biomaterials was investigated. The purpose was to recommend optimum machining conditions that produce standardized roughness in biomedical implants. The study material was acquired as ø38 x 6m rods. From these bars, test specimens of Ø30x200 mm were made. These measures were selected in order to meet the requirement of ISO 3685 and avoid vibrations. The tests were carried out on a MILLTRONICS lathe (CNC) model ML-16. The cutting conditions were: Vc = 50, 75 and 100 m / min; A = 0.1, 0.15 and 0.25 mm / rev; P = 0.5, 0.7, 09 mm, R (insert edge radius) = 0.4, 08, 1.2 mm. The roughness measurements were performed using the SURFTEST-210 MITUTOYO Rough Meter. At the end of each turning operation, the average roughness values of the cylindrical surface shall be taken taking a cut distance of 2.5 mm for the measurements. The results show that for these alloys, the finer values of roughness are not always found with small advances, low depth, and high speeds as with metals. It depends on the integrated set of all variables where, like metals, advancement and radius of edge are the most influential variables. The minimum roughness value in all the tests was: 0.82 μm; was found using a radius insert "R = 0.8 mm, and cutting regime: [V = 50 m / min; A = 0.1 mm / rev; P = 0.7 mm]. The most influential variable in the roughness is the advance, followed by the cutting edge radius. A lower feed decreases the roughness, and the same happens when the edge radius increases. The cutting speed exerts a greater influence than the depth. No smooth surfaces have been achieved: (Ra <0.5 mm); but, it has been achieved minimally rough surfaces: (0.5 <Ra <1 μm); These were presented with inserts R = 0.8 and R = 1.2 under 6 different cutting conditions. Moderately rough surfaces: [1.0 and 2.0 μm] were found in 36 trials out of a total of 81. Finally, it was found that of all the tests (~ 50%) meets the standards required for biomedical implants with regard to roughness. It is concluded that in many cases it is not necessary to coat the implants to be able to use them, they can be used directly after a fine machining.
publishDate 2017
dc.date.accessioned.none.fl_str_mv 12/26/2017 9:52
dc.date.available.none.fl_str_mv 12/26/2017 9:52
dc.date.issued.fl_str_mv 2017-06-27
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/9385
url https://hdl.handle.net/20.500.14414/9385
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.relation.ispartofseries.none.fl_str_mv TMEC 9378;9378
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.es_PE.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_PE.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/4c5a35fb-05c8-4d27-a0b4-c4539bb31c6d/download
https://dspace.unitru.edu.pe/bitstreams/bf1b11aa-91fe-4c9c-9536-bab8df77fe4e/download
bitstream.checksum.fl_str_mv 736dc5cadfe83fa10029e51db5e2d1b9
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290165924724736
spelling Alcántara Alza, Víctor ManuelCastro Zavaleta, Santos Homero12/26/2017 9:5212/26/2017 9:522017-06-27https://hdl.handle.net/20.500.14414/9385As the cutting regime and tool geometry on surface roughness influence the turning of the Co-28Cr-6Mo alloys used as biomaterials was investigated. The purpose was to recommend optimum machining conditions that produce standardized roughness in biomedical implants. The study material was acquired as ø38 x 6m rods. From these bars, test specimens of Ø30x200 mm were made. These measures were selected in order to meet the requirement of ISO 3685 and avoid vibrations. The tests were carried out on a MILLTRONICS lathe (CNC) model ML-16. The cutting conditions were: Vc = 50, 75 and 100 m / min; A = 0.1, 0.15 and 0.25 mm / rev; P = 0.5, 0.7, 09 mm, R (insert edge radius) = 0.4, 08, 1.2 mm. The roughness measurements were performed using the SURFTEST-210 MITUTOYO Rough Meter. At the end of each turning operation, the average roughness values of the cylindrical surface shall be taken taking a cut distance of 2.5 mm for the measurements. The results show that for these alloys, the finer values of roughness are not always found with small advances, low depth, and high speeds as with metals. It depends on the integrated set of all variables where, like metals, advancement and radius of edge are the most influential variables. The minimum roughness value in all the tests was: 0.82 μm; was found using a radius insert "R = 0.8 mm, and cutting regime: [V = 50 m / min; A = 0.1 mm / rev; P = 0.7 mm]. The most influential variable in the roughness is the advance, followed by the cutting edge radius. A lower feed decreases the roughness, and the same happens when the edge radius increases. The cutting speed exerts a greater influence than the depth. No smooth surfaces have been achieved: (Ra <0.5 mm); but, it has been achieved minimally rough surfaces: (0.5 <Ra <1 μm); These were presented with inserts R = 0.8 and R = 1.2 under 6 different cutting conditions. Moderately rough surfaces: [1.0 and 2.0 μm] were found in 36 trials out of a total of 81. Finally, it was found that of all the tests (~ 50%) meets the standards required for biomedical implants with regard to roughness. It is concluded that in many cases it is not necessary to coat the implants to be able to use them, they can be used directly after a fine machining.Se investigó cómo influye el régimen de corte y la geometría de la herramienta, sobre la rugosidad superficial, en el torneado de las aleaciónes Co-28Cr-6Mo que se usan como biomateriales. El propósito fue recomendar las condiciones de corte óptimas de mecanizado que produzcan rugosidades estandarizados en los implantes biomédicos. El material de estudio se adquirió como barras de ø38 x 6m. De estas barras se confeccionaron probetas de ensayo de Ø30x200 mm. Estas medidas se seleccionaron con el fin de cumplir con el requisito de la norma ISO 3685 y evitar vibraciones. Los ensayos se llevaron a cabo en un torno (CNC) MILLTRONICS modelo ML-16. Las condiciones de corte fueron: Vc = 50, 75 y 100 m/min; A = 0,1, 0,15 y 0,25 mm/rev; P = 0,5, 0,7, 09 mm, R (radio de filo de inserto) = 0,4, 08, 1,2 mm. Las medidas de rugosidad se realizaron utilizando el Rugosímetro MITUTOYO modelo SURFTEST-210. Al final de cada operación de torneado, se tomaran los valores medios de rugosidad de la superficie cilíndrica tomando una distancia de corte de 2,5 mm para las mediciones. Los resultados muestran que para estas aleaciones, los valores más finos de rugosidad no siempre se encuentran con avances pequeños, baja profundidad, y altas velocidades como sucede con los metales. Depende del conjunto integrado de todas las variables donde al igual que los metales, el avance y el radio de filo son las variables más influyentes. El valor mínimo de rugosidad en todos los ensayos fue de: 0,82 μm; se encontró empleando un inserto de radio “R= 0,8 mm, y régimen de corte: [V= 50 m/min; a = 0,1 mm/rev; p = 0,7 mm]. La variable más influyente en la rugosidad es el avance, seguido del radio de filo de corte. Un menor avance disminuye la rugosidad, y lo mismo sucede cuando el radio de filo se incrementa. La velocidad de corte ejerce mayor influencia que la profundidad. No se han conseguido superficies lisas: (Ra < 0,5 mm); pero si, superficies mínimamente ásperas con rugosidades: (0,5 < Ra < 1 μm); estas se presentaron con insertos R = 0,8 y R = 1,2 bajo 6 condiciones de corte distintas. Las superficies moderadamente rugosas: [1,0 y 2,0 μm,] se encontraron en 36 ensayos de un total de 81. Finalmente se encontró que de todos los ensayos ~ el 50 % cumple con los estándares exigidos para los implantes biomédicos respecto a la rugosidad. Se concluye que en muchos casos no es necesario recubrir los implantes para poder usarlos, pueden ser directamente utilizados después de un mecanizado fino.TesisspaUniversidad Nacional de TrujilloTMEC 9378;9378SUNEDUinfo:eu-repo/semantics/openAccessUniversidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRURugosidad superficial, Torneado de aleacionesEfectos del regimen de corte y perfil de la herramienta sobre La rugosidad superficial en el torneado de aleaciones Co-28cr-6mo de uso biomédicoinfo:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero MecánicoIngenieríaUniversidad Nacional de Trujillo. Facultad de IngenieríaORIGINALCASTRO ZAVALETA, SANTOS HOMERO.pdfCASTRO ZAVALETA, SANTOS HOMERO.pdfapplication/pdf7512141https://dspace.unitru.edu.pe/bitstreams/4c5a35fb-05c8-4d27-a0b4-c4539bb31c6d/download736dc5cadfe83fa10029e51db5e2d1b9MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/bf1b11aa-91fe-4c9c-9536-bab8df77fe4e/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/9385oai:dspace.unitru.edu.pe:20.500.14414/93852024-04-21 13:06:17.652open.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.95884
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).