Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona
Descripción del Articulo
The present study proposes the application of a maintenance program focused on reliability for horizontal centrifugal pumps Warman 450 MCR developed in the mining project Cerro Corona, with the aim of increasing its availability. The application of reliability is based on a criticality analysis of t...
Autor: | |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2017 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/9291 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/9291 |
Nivel de acceso: | acceso abierto |
Materia: | Bombas centrifugas |
id |
UNIT_216ecbf2319ada6bdf81fac0b1c30115 |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/9291 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_PE.fl_str_mv |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
title |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
spellingShingle |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona Santillan Armas, Cristian Paul Bombas centrifugas |
title_short |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
title_full |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
title_fullStr |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
title_full_unstemmed |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
title_sort |
Programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Corona |
author |
Santillan Armas, Cristian Paul |
author_facet |
Santillan Armas, Cristian Paul |
author_role |
author |
dc.contributor.advisor.fl_str_mv |
Azabache Vasquez, Eduardo |
dc.contributor.author.fl_str_mv |
Santillan Armas, Cristian Paul |
dc.subject.es_PE.fl_str_mv |
Bombas centrifugas |
topic |
Bombas centrifugas |
description |
The present study proposes the application of a maintenance program focused on reliability for horizontal centrifugal pumps Warman 450 MCR developed in the mining project Cerro Corona, with the aim of increasing its availability. The application of reliability is based on a criticality analysis of the equipment and then based on the seven questions of the RCM define the main function, functional failure, failure modes, effects and consequences, analyze if there is a proactive maintenance and if not analyze a Change in equipment design. Then with the data of the SAP software of the company we elaborated a graph of dispersion of the faults, where we identify the chronic and acute faults that are generating the unavailability of the equipment. Then, we apply the Weibull statistical model to the two failure modes identified, as well as using the cost curve as a decision tool to obtain the equipment intervention optimization time. It is concluded that the failure modes that generate unavailability due to reliability and maintainability are the GAP Regulation and the Dish Change and Suction Liners. It also shows the reliability and cost curves that will help to make decisions about the intervention time, the reliability and the associated cost. |
publishDate |
2017 |
dc.date.accessioned.none.fl_str_mv |
12/7/2017 11:37 |
dc.date.available.none.fl_str_mv |
12/7/2017 11:37 |
dc.date.issued.fl_str_mv |
2017-03 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/9291 |
url |
https://hdl.handle.net/20.500.14414/9291 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.relation.ispartofseries.none.fl_str_mv |
Tmec 9324;9324 |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/5c91cff1-7963-4770-800c-1fbcdb4f8278/download https://dspace.unitru.edu.pe/bitstreams/e243620c-ca6e-4c68-8d7f-5a2ebe74e6f1/download |
bitstream.checksum.fl_str_mv |
9f5c8fd2111e88188a3dfbe01187a88f 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807290236307243008 |
spelling |
Azabache Vasquez, EduardoSantillan Armas, Cristian Paul12/7/2017 11:3712/7/2017 11:372017-03https://hdl.handle.net/20.500.14414/9291The present study proposes the application of a maintenance program focused on reliability for horizontal centrifugal pumps Warman 450 MCR developed in the mining project Cerro Corona, with the aim of increasing its availability. The application of reliability is based on a criticality analysis of the equipment and then based on the seven questions of the RCM define the main function, functional failure, failure modes, effects and consequences, analyze if there is a proactive maintenance and if not analyze a Change in equipment design. Then with the data of the SAP software of the company we elaborated a graph of dispersion of the faults, where we identify the chronic and acute faults that are generating the unavailability of the equipment. Then, we apply the Weibull statistical model to the two failure modes identified, as well as using the cost curve as a decision tool to obtain the equipment intervention optimization time. It is concluded that the failure modes that generate unavailability due to reliability and maintainability are the GAP Regulation and the Dish Change and Suction Liners. It also shows the reliability and cost curves that will help to make decisions about the intervention time, the reliability and the associated cost.El presente estudio propone la aplicación de un programa de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales Warman 450 MCR desarrollado en el proyecto minero Cerro Corona, con el objetivo de aumentar su disponibilidad. La aplicación de confiabilidad se basa en un análisis de criticidad del equipo para luego en base a las siete preguntas del RCM definir la función principal, falla funcional, modos de falla, efectos y consecuencias, analizar si existe un mantenimiento proactivo y caso contrario analizar un cambio en el diseño del equipo. Luego con los datos del software SAP de la empresa elaboramos un gráfico de dispersión de las fallas, donde identificamos las fallas crónicas y agudas las que están generando la indisponibilidad del equipo. A continuación, aplicamos el modelo estadístico de Weibull a los dos modos de falla identificados además de usar como herramienta de decisión la curva de costos y así obtener el tiempo de optimización de intervención del equipo. Se concluye que los modos de falla que generan indisponibilidad debido a confiabilidad y mantenibilidad son la Regulación de GAP y el Cambio de plato y Forros Succión. Así mismo se muestran las curvas de confiabilidad y costos que ayudaran a tomar decisiones sobre el tiempo de intervención, la confiabilidad y el costo asociadospaUniversidad Nacional de TrujilloTmec 9324;9324SUNEDUinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUBombas centrifugasPrograma de mantenimiento centrado en confiabilidad para bombas centrifugas horizontales warman 450 mcr en Minera Cerro Coronainfo:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero MecánicoIngenieríaUniversidad Nacional de Trujillo. Facultad de IngenieríaORIGINALSANTILLAN ARMAS, CHRISTIAN PAUL.pdfSANTILLAN ARMAS, CHRISTIAN PAUL.pdfBombas centrifugasapplication/pdf5313406https://dspace.unitru.edu.pe/bitstreams/5c91cff1-7963-4770-800c-1fbcdb4f8278/download9f5c8fd2111e88188a3dfbe01187a88fMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/e243620c-ca6e-4c68-8d7f-5a2ebe74e6f1/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/9291oai:dspace.unitru.edu.pe:20.500.14414/92912024-04-21 13:06:18.173http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.919782 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).