Dielectric spectroscopy for the prediction of pork quality during the post-mortem time
Descripción del Articulo
Dielectric spectroscopy was used in this study to predict and classify pork quality during the post-mortem time. Eighty ~1 kg- longissimus dorsi muscles were collected and stored at 4 ± 1 ◦C and pH, instrumental color, and dielectric properties (ε’ and ε’’) were subsequently determined in the microw...
| Autores: | , , , , , , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2025 |
| Institución: | Universidad Nacional Autónoma de Chota |
| Repositorio: | UNACH-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.unach.edu.pe:20.500.14142/776 |
| Enlace del recurso: | https://repositorio.unach.edu.pe/handle/20.500.14142/776 https://doi.org/10.1016/j.jfca.2025.108128 |
| Nivel de acceso: | acceso abierto |
| Materia: | food https://purl.org/pe-repo/ocde/ford#4.03.01 |
| id |
UNCH_588170c1f9ca28cf2d24edc14484ae01 |
|---|---|
| oai_identifier_str |
oai:repositorio.unach.edu.pe:20.500.14142/776 |
| network_acronym_str |
UNCH |
| network_name_str |
UNACH-Institucional |
| repository_id_str |
4826 |
| dc.title.none.fl_str_mv |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| title |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| spellingShingle |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time Chuquizuta Trigoso, Tony Steven food https://purl.org/pe-repo/ocde/ford#4.03.01 |
| title_short |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| title_full |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| title_fullStr |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| title_full_unstemmed |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| title_sort |
Dielectric spectroscopy for the prediction of pork quality during the post-mortem time |
| author |
Chuquizuta Trigoso, Tony Steven |
| author_facet |
Chuquizuta Trigoso, Tony Steven Peralta, Magaly Medina, Sideli Arteaga, Hubert Oblitas, Jimy Chavez, Segundo G. Castro, Wilson Manuel Castro-Giraldez, Marta Fito, Pedro Juan |
| author_role |
author |
| author2 |
Peralta, Magaly Medina, Sideli Arteaga, Hubert Oblitas, Jimy Chavez, Segundo G. Castro, Wilson Manuel Castro-Giraldez, Marta Fito, Pedro Juan |
| author2_role |
author author author author author author author author |
| dc.contributor.author.fl_str_mv |
Chuquizuta Trigoso, Tony Steven Peralta, Magaly Medina, Sideli Arteaga, Hubert Oblitas, Jimy Chavez, Segundo G. Castro, Wilson Manuel Castro-Giraldez, Marta Fito, Pedro Juan |
| dc.subject.none.fl_str_mv |
food |
| topic |
food https://purl.org/pe-repo/ocde/ford#4.03.01 |
| dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#4.03.01 |
| description |
Dielectric spectroscopy was used in this study to predict and classify pork quality during the post-mortem time. Eighty ~1 kg- longissimus dorsi muscles were collected and stored at 4 ± 1 ◦C and pH, instrumental color, and dielectric properties (ε’ and ε’’) were subsequently determined in the microwave range (0.5–9 GHz) at 3, 4, 5, 6, 7, 8, 9, 10 and 24 h post-mortem (hpm), as well as moisture at 8 hpm and drip weight loss at 24 hpm. Of the 80 pork samples, two types of meat were found. RFN (33) and DFD (47) between males and females. Quality parameters: RFN (pH=5.708–5.714; L*=43.341–43.692; moisture (%) = 68.857–69.604; drip loss = 1.655–1.833) and DFD (pH=6.154–6.177; L*=40.152–41.91; moisture (%) = 69.032–69.9; drip loss = 1.129–1.693). Quality parameter predictions during muscle-to-meat transformation showed R² of 0.743 (pH), 0.811 (L*) and 0.603 (C*) for DFD meats with PLSR (full) and R2 of 0.359 (pH), 0.558 (L*) and 0.284 (C*) for RNF meats with PLSR (optimized) from male pigs. R2 cv of 0.412–0.637 for pH, L* and c* for RFN and DFD meats from female pigs with PLSR (optimized). Dielectric spectroscopy predicts pork quality moderately well, but models that are more robust are needed to improve predictions of internal pork quality. |
| publishDate |
2025 |
| dc.date.accessioned.none.fl_str_mv |
2025-09-15T14:43:48Z |
| dc.date.available.none.fl_str_mv |
2025-09-15T14:43:48Z |
| dc.date.issued.fl_str_mv |
2025-08 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.version.none.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.none.fl_str_mv |
https://repositorio.unach.edu.pe/handle/20.500.14142/776 |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1016/j.jfca.2025.108128 |
| url |
https://repositorio.unach.edu.pe/handle/20.500.14142/776 https://doi.org/10.1016/j.jfca.2025.108128 |
| dc.language.iso.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.none.fl_str_mv |
Journal of Food Composition and Analysis |
| dc.relation.isPartOf.none.fl_str_mv |
urn:issn: 08891575 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.none.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| dc.publisher.country.none.fl_str_mv |
NL |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:UNACH-Institucional instname:Universidad Nacional Autónoma de Chota instacron:UNACH |
| instname_str |
Universidad Nacional Autónoma de Chota |
| instacron_str |
UNACH |
| institution |
UNACH |
| reponame_str |
UNACH-Institucional |
| collection |
UNACH-Institucional |
| bitstream.url.fl_str_mv |
https://repositorio.unach.edu.pe/bitstreams/8121f0f7-556f-4e1f-a588-515242417aac/download https://repositorio.unach.edu.pe/bitstreams/f01dfe82-2f90-474a-839e-9ade45eda771/download https://repositorio.unach.edu.pe/bitstreams/1e4777cc-a1c2-4144-a538-7096c080db04/download |
| bitstream.checksum.fl_str_mv |
1f9949d09a4e492cea60c2f3d6a2477a bb9bdc0b3349e4284e09149f943790b4 389b06ed71bc68d0fb7017c11e0db0f4 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio UNACH |
| repository.mail.fl_str_mv |
dspace-help@myu.edu |
| _version_ |
1870171330847965184 |
| spelling |
Chuquizuta Trigoso, Tony StevenPeralta, MagalyMedina, SideliArteaga, HubertOblitas, JimyChavez, Segundo G.Castro, Wilson ManuelCastro-Giraldez, MartaFito, Pedro Juan2025-09-15T14:43:48Z2025-09-15T14:43:48Z2025-08https://repositorio.unach.edu.pe/handle/20.500.14142/776https://doi.org/10.1016/j.jfca.2025.108128Dielectric spectroscopy was used in this study to predict and classify pork quality during the post-mortem time. Eighty ~1 kg- longissimus dorsi muscles were collected and stored at 4 ± 1 ◦C and pH, instrumental color, and dielectric properties (ε’ and ε’’) were subsequently determined in the microwave range (0.5–9 GHz) at 3, 4, 5, 6, 7, 8, 9, 10 and 24 h post-mortem (hpm), as well as moisture at 8 hpm and drip weight loss at 24 hpm. Of the 80 pork samples, two types of meat were found. RFN (33) and DFD (47) between males and females. Quality parameters: RFN (pH=5.708–5.714; L*=43.341–43.692; moisture (%) = 68.857–69.604; drip loss = 1.655–1.833) and DFD (pH=6.154–6.177; L*=40.152–41.91; moisture (%) = 69.032–69.9; drip loss = 1.129–1.693). Quality parameter predictions during muscle-to-meat transformation showed R² of 0.743 (pH), 0.811 (L*) and 0.603 (C*) for DFD meats with PLSR (full) and R2 of 0.359 (pH), 0.558 (L*) and 0.284 (C*) for RNF meats with PLSR (optimized) from male pigs. R2 cv of 0.412–0.637 for pH, L* and c* for RFN and DFD meats from female pigs with PLSR (optimized). Dielectric spectroscopy predicts pork quality moderately well, but models that are more robust are needed to improve predictions of internal pork quality.This research received funding for the payment of APC from the Vice-Rectorate of Research of the Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas.application/pdfengElsevierNLJournal of Food Composition and Analysisurn:issn: 08891575info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/4.0/foodhttps://purl.org/pe-repo/ocde/ford#4.03.01Dielectric spectroscopy for the prediction of pork quality during the post-mortem timeinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionreponame:UNACH-Institucionalinstname:Universidad Nacional Autónoma de Chotainstacron:UNACHORIGINAL1-s2.0-S0889157525009433-main.pdf1-s2.0-S0889157525009433-main.pdfapplication/pdf11067790https://repositorio.unach.edu.pe/bitstreams/8121f0f7-556f-4e1f-a588-515242417aac/download1f9949d09a4e492cea60c2f3d6a2477aMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.unach.edu.pe/bitstreams/f01dfe82-2f90-474a-839e-9ade45eda771/downloadbb9bdc0b3349e4284e09149f943790b4MD52THUMBNAIL2.jpgimage/jpeg223532https://repositorio.unach.edu.pe/bitstreams/1e4777cc-a1c2-4144-a538-7096c080db04/download389b06ed71bc68d0fb7017c11e0db0f4MD5320.500.14142/776oai:repositorio.unach.edu.pe:20.500.14142/7762025-09-15 17:01:10.69https://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessopen.accesshttps://repositorio.unach.edu.peRepositorio UNACHdspace-help@myu.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 |
| score |
12.824051 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).