Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A

Descripción del Articulo

The purpose of this research work was to compare the conductometrics with the Propex Pixi electronic apical locator and the YS-RZ-A apical locator. The type of research was quantitative, quasi-experimental design, comparative descriptive, cross-sectional. The sample consisted of 20 premolar teeth. T...

Descripción completa

Detalles Bibliográficos
Autores: Trindade Gayoso, Caroline, Rengifo Paima, Nicole del Rocío
Formato: tesis de grado
Fecha de Publicación:2022
Institución:Universidad Nacional De La Amazonía Peruana
Repositorio:UNAPIquitos-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unapiquitos.edu.pe:20.500.12737/8080
Enlace del recurso:https://hdl.handle.net/20.500.12737/8080
Nivel de acceso:acceso abierto
Materia:Conductometría
Diente premolar
Ápice del diente
http://purl.org/pe-repo/ocde/ford#3.02.14
id UNAP_908b093209b207937349594be34b88f6
oai_identifier_str oai:repositorio.unapiquitos.edu.pe:20.500.12737/8080
network_acronym_str UNAP
network_name_str UNAPIquitos-Institucional
repository_id_str 4362
dc.title.es_PE.fl_str_mv Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
title Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
spellingShingle Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
Trindade Gayoso, Caroline
Conductometría
Diente premolar
Ápice del diente
http://purl.org/pe-repo/ocde/ford#3.02.14
title_short Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
title_full Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
title_fullStr Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
title_full_unstemmed Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
title_sort Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
author Trindade Gayoso, Caroline
author_facet Trindade Gayoso, Caroline
Rengifo Paima, Nicole del Rocío
author_role author
author2 Rengifo Paima, Nicole del Rocío
author2_role author
dc.contributor.advisor.fl_str_mv Sologuren Anchante, Rafael Fernando
dc.contributor.author.fl_str_mv Trindade Gayoso, Caroline
Rengifo Paima, Nicole del Rocío
dc.subject.es_PE.fl_str_mv Conductometría
Diente premolar
Ápice del diente
topic Conductometría
Diente premolar
Ápice del diente
http://purl.org/pe-repo/ocde/ford#3.02.14
dc.subject.ocde.es_PE.fl_str_mv http://purl.org/pe-repo/ocde/ford#3.02.14
description The purpose of this research work was to compare the conductometrics with the Propex Pixi electronic apical locator and the YS-RZ-A apical locator. The type of research was quantitative, quasi-experimental design, comparative descriptive, cross-sectional. The sample consisted of 20 premolar teeth. The results that stood out the most were: The average of the measurements of the conductometrics with Propex Pixi was 17.68 mm. The mean of the conductometric measurements with YS-RZ-A was 17.50 mm. The most frequent conductometry with LAE Propex Pixi was 16.00 mm; followed by 19.50mm. The most frequent conductometry with LAE YS-RZ-A was 17.00 mm; 18.00mm and 19.00mm. The average measurement at the apical foramen with LAE Propex Pixi was 18.68 mm and at the anatomical foramen it was 19.10 mm. The average measurement at the apical foramen with LAE YS-RZ-A was 18.50 mm and at the anatomical foramen it was 19.10 mm. In none of the cases did the Electronic Apical Locators exceed the apical foramen. There is a significant difference between the measurement at the apical foramen with the LAE Propex Pixi and the anatomical apical foramen (p=0.000). There is a significant difference between the measurement at the apical foramen with the LAE YS-RZ-A and the anatomical apical foramen (p=0.000). There are no significant differences between the conductometrics obtained with LAE Propex Pixi and YS-RZ-A (p=0.763).
publishDate 2022
dc.date.accessioned.none.fl_str_mv 2022-06-15T17:02:34Z
dc.date.available.none.fl_str_mv 2022-06-15T17:02:34Z
dc.date.issued.fl_str_mv 2022
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12737/8080
url https://hdl.handle.net/20.500.12737/8080
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Universidad Nacional de la Amazonía Peruana
dc.publisher.country.es_PE.fl_str_mv PE
dc.source.none.fl_str_mv reponame:UNAPIquitos-Institucional
instname:Universidad Nacional De La Amazonía Peruana
instacron:UNAPIquitos
instname_str Universidad Nacional De La Amazonía Peruana
instacron_str UNAPIquitos
institution UNAPIquitos
reponame_str UNAPIquitos-Institucional
collection UNAPIquitos-Institucional
bitstream.url.fl_str_mv https://demo7-repo.unapiquitos.edu.pe/bitstreams/86f61381-0fa3-458a-979f-cf02f5d44400/download
https://demo7-repo.unapiquitos.edu.pe/bitstreams/0c240acb-7d8d-40fc-8aa2-5b7a31d1e181/download
https://demo7-repo.unapiquitos.edu.pe/bitstreams/4cd97529-fc81-4e47-b651-52dc55d8d1ef/download
bitstream.checksum.fl_str_mv a06b07fa5f304ac6fd806af228c2b16b
7d3b33c232411f7a4c1fc9727d4c7661
2075821e1037e8f23f9bc8f4102490e3
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Digital UNAP
repository.mail.fl_str_mv repositorio.institucional@unapiquitos.edu.pe
_version_ 1844710824367620096
spelling Sologuren Anchante, Rafael FernandoTrindade Gayoso, CarolineRengifo Paima, Nicole del Rocío2022-06-15T17:02:34Z2022-06-15T17:02:34Z2022https://hdl.handle.net/20.500.12737/8080The purpose of this research work was to compare the conductometrics with the Propex Pixi electronic apical locator and the YS-RZ-A apical locator. The type of research was quantitative, quasi-experimental design, comparative descriptive, cross-sectional. The sample consisted of 20 premolar teeth. The results that stood out the most were: The average of the measurements of the conductometrics with Propex Pixi was 17.68 mm. The mean of the conductometric measurements with YS-RZ-A was 17.50 mm. The most frequent conductometry with LAE Propex Pixi was 16.00 mm; followed by 19.50mm. The most frequent conductometry with LAE YS-RZ-A was 17.00 mm; 18.00mm and 19.00mm. The average measurement at the apical foramen with LAE Propex Pixi was 18.68 mm and at the anatomical foramen it was 19.10 mm. The average measurement at the apical foramen with LAE YS-RZ-A was 18.50 mm and at the anatomical foramen it was 19.10 mm. In none of the cases did the Electronic Apical Locators exceed the apical foramen. There is a significant difference between the measurement at the apical foramen with the LAE Propex Pixi and the anatomical apical foramen (p=0.000). There is a significant difference between the measurement at the apical foramen with the LAE YS-RZ-A and the anatomical apical foramen (p=0.000). There are no significant differences between the conductometrics obtained with LAE Propex Pixi and YS-RZ-A (p=0.763).La finalidad de este trabajo de investigación fue la comparación de la conductometría con el localizador apical electrónico Propex Pixi y el localizador apical YS-RZ-A. El tipo de investigación fue cuantitativa, el diseño cuasi-experimental, descriptivo comparativo, transversal. La muestra fue conformada por 20 dientes premolares. Los resultados destacados fueron: El promedio de las medidas de conductometría con Propex Pixi fue 17,68 mm. El promedio de las medidas de conductometría con YS-RZ-A fue 17,50 mm. La conductometría más frecuente con LAE Propex Pixi fue 16,00 mm; seguido de 19,50 mm. La conductometría más frecuente con LAE YS-RZ-A fue 17,00 mm; 18,00 mm y 19,00 mm. El promedio de medidas al foramen apical con LAE Propex Pixi fue 18,68 mm y al anatómico fue 19,10 mm. El promedio de medidas al foramen apical con LAE YS-RZ-A fue 18,50 mm y al anatómico fue 19,10 mm. En ninguno de los casos los Localizadores Apicales Electrónicos sobrepasaron el foramen apical. Existe diferencia significativa entre la medida al foramen apical con el LAE Propex Pixi y el foramen apical anatómico (p=0,000). Existe diferencia significativa entre la medida al foramen apical con el LAE YS-RZ-A y el foramen apical anatómico (p=0,000). No existe diferencias significativas entre las conductometrías obtenidas con LAE Propex Pixi y YS-RZ-A (p=0,763).application/pdfspaUniversidad Nacional de la Amazonía PeruanaPEinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/ConductometríaDiente premolarÁpice del dientehttp://purl.org/pe-repo/ocde/ford#3.02.14Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-Ainfo:eu-repo/semantics/bachelorThesisreponame:UNAPIquitos-Institucionalinstname:Universidad Nacional De La Amazonía Peruanainstacron:UNAPIquitosSUNEDUOdontologíaUniversidad Nacional de la Amazonía Peruana. Facultad de OdontologíaCirujano Dentista7862752175560135https://orcid.org/0000-0002-1632-082121522076https://purl.org/pe-repo/renati/type#tesis911026https://purl.org/pe-repo/renati/level#tituloProfesionalBardales Ríos, Jorge FranciscoPanduro Del Castillo, Myriam Betty|Camiñas Gómez, Lina MarliORIGINALCaroline_Tesis_Titulo_2022.pdfCaroline_Tesis_Titulo_2022.pdfTexto completoapplication/pdf762836https://demo7-repo.unapiquitos.edu.pe/bitstreams/86f61381-0fa3-458a-979f-cf02f5d44400/downloada06b07fa5f304ac6fd806af228c2b16bMD51trueAnonymousREADTEXTCaroline_Tesis_Titulo_2022.pdf.txtCaroline_Tesis_Titulo_2022.pdf.txtExtracted texttext/plain39704https://demo7-repo.unapiquitos.edu.pe/bitstreams/0c240acb-7d8d-40fc-8aa2-5b7a31d1e181/download7d3b33c232411f7a4c1fc9727d4c7661MD52falseAnonymousREADTHUMBNAILCaroline_Tesis_Titulo_2022.pdf.jpgCaroline_Tesis_Titulo_2022.pdf.jpgGenerated Thumbnailimage/jpeg3127https://demo7-repo.unapiquitos.edu.pe/bitstreams/4cd97529-fc81-4e47-b651-52dc55d8d1ef/download2075821e1037e8f23f9bc8f4102490e3MD53falseAnonymousREAD20.500.12737/8080oai:demo7-repo.unapiquitos.edu.pe:20.500.12737/80802025-08-08T18:17:09.160054Zhttps://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessopen.accesshttps://demo7-repo.unapiquitos.edu.peRepositorio Digital UNAPrepositorio.institucional@unapiquitos.edu.pe
score 13.072484
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).