Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A
Descripción del Articulo
The purpose of this research work was to compare the conductometrics with the Propex Pixi electronic apical locator and the YS-RZ-A apical locator. The type of research was quantitative, quasi-experimental design, comparative descriptive, cross-sectional. The sample consisted of 20 premolar teeth. T...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2022 |
Institución: | Universidad Nacional De La Amazonía Peruana |
Repositorio: | UNAPIquitos-Institucional |
Lenguaje: | español |
OAI Identifier: | oai:repositorio.unapiquitos.edu.pe:20.500.12737/8080 |
Enlace del recurso: | https://hdl.handle.net/20.500.12737/8080 |
Nivel de acceso: | acceso abierto |
Materia: | Conductometría Diente premolar Ápice del diente http://purl.org/pe-repo/ocde/ford#3.02.14 |
id |
UNAP_908b093209b207937349594be34b88f6 |
---|---|
oai_identifier_str |
oai:repositorio.unapiquitos.edu.pe:20.500.12737/8080 |
network_acronym_str |
UNAP |
network_name_str |
UNAPIquitos-Institucional |
repository_id_str |
4362 |
dc.title.es_PE.fl_str_mv |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
title |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
spellingShingle |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A Trindade Gayoso, Caroline Conductometría Diente premolar Ápice del diente http://purl.org/pe-repo/ocde/ford#3.02.14 |
title_short |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
title_full |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
title_fullStr |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
title_full_unstemmed |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
title_sort |
Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-A |
author |
Trindade Gayoso, Caroline |
author_facet |
Trindade Gayoso, Caroline Rengifo Paima, Nicole del Rocío |
author_role |
author |
author2 |
Rengifo Paima, Nicole del Rocío |
author2_role |
author |
dc.contributor.advisor.fl_str_mv |
Sologuren Anchante, Rafael Fernando |
dc.contributor.author.fl_str_mv |
Trindade Gayoso, Caroline Rengifo Paima, Nicole del Rocío |
dc.subject.es_PE.fl_str_mv |
Conductometría Diente premolar Ápice del diente |
topic |
Conductometría Diente premolar Ápice del diente http://purl.org/pe-repo/ocde/ford#3.02.14 |
dc.subject.ocde.es_PE.fl_str_mv |
http://purl.org/pe-repo/ocde/ford#3.02.14 |
description |
The purpose of this research work was to compare the conductometrics with the Propex Pixi electronic apical locator and the YS-RZ-A apical locator. The type of research was quantitative, quasi-experimental design, comparative descriptive, cross-sectional. The sample consisted of 20 premolar teeth. The results that stood out the most were: The average of the measurements of the conductometrics with Propex Pixi was 17.68 mm. The mean of the conductometric measurements with YS-RZ-A was 17.50 mm. The most frequent conductometry with LAE Propex Pixi was 16.00 mm; followed by 19.50mm. The most frequent conductometry with LAE YS-RZ-A was 17.00 mm; 18.00mm and 19.00mm. The average measurement at the apical foramen with LAE Propex Pixi was 18.68 mm and at the anatomical foramen it was 19.10 mm. The average measurement at the apical foramen with LAE YS-RZ-A was 18.50 mm and at the anatomical foramen it was 19.10 mm. In none of the cases did the Electronic Apical Locators exceed the apical foramen. There is a significant difference between the measurement at the apical foramen with the LAE Propex Pixi and the anatomical apical foramen (p=0.000). There is a significant difference between the measurement at the apical foramen with the LAE YS-RZ-A and the anatomical apical foramen (p=0.000). There are no significant differences between the conductometrics obtained with LAE Propex Pixi and YS-RZ-A (p=0.763). |
publishDate |
2022 |
dc.date.accessioned.none.fl_str_mv |
2022-06-15T17:02:34Z |
dc.date.available.none.fl_str_mv |
2022-06-15T17:02:34Z |
dc.date.issued.fl_str_mv |
2022 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12737/8080 |
url |
https://hdl.handle.net/20.500.12737/8080 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.*.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
dc.format.es_PE.fl_str_mv |
application/pdf |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de la Amazonía Peruana |
dc.publisher.country.es_PE.fl_str_mv |
PE |
dc.source.none.fl_str_mv |
reponame:UNAPIquitos-Institucional instname:Universidad Nacional De La Amazonía Peruana instacron:UNAPIquitos |
instname_str |
Universidad Nacional De La Amazonía Peruana |
instacron_str |
UNAPIquitos |
institution |
UNAPIquitos |
reponame_str |
UNAPIquitos-Institucional |
collection |
UNAPIquitos-Institucional |
bitstream.url.fl_str_mv |
https://demo7-repo.unapiquitos.edu.pe/bitstreams/86f61381-0fa3-458a-979f-cf02f5d44400/download https://demo7-repo.unapiquitos.edu.pe/bitstreams/0c240acb-7d8d-40fc-8aa2-5b7a31d1e181/download https://demo7-repo.unapiquitos.edu.pe/bitstreams/4cd97529-fc81-4e47-b651-52dc55d8d1ef/download |
bitstream.checksum.fl_str_mv |
a06b07fa5f304ac6fd806af228c2b16b 7d3b33c232411f7a4c1fc9727d4c7661 2075821e1037e8f23f9bc8f4102490e3 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Digital UNAP |
repository.mail.fl_str_mv |
repositorio.institucional@unapiquitos.edu.pe |
_version_ |
1844710824367620096 |
spelling |
Sologuren Anchante, Rafael FernandoTrindade Gayoso, CarolineRengifo Paima, Nicole del Rocío2022-06-15T17:02:34Z2022-06-15T17:02:34Z2022https://hdl.handle.net/20.500.12737/8080The purpose of this research work was to compare the conductometrics with the Propex Pixi electronic apical locator and the YS-RZ-A apical locator. The type of research was quantitative, quasi-experimental design, comparative descriptive, cross-sectional. The sample consisted of 20 premolar teeth. The results that stood out the most were: The average of the measurements of the conductometrics with Propex Pixi was 17.68 mm. The mean of the conductometric measurements with YS-RZ-A was 17.50 mm. The most frequent conductometry with LAE Propex Pixi was 16.00 mm; followed by 19.50mm. The most frequent conductometry with LAE YS-RZ-A was 17.00 mm; 18.00mm and 19.00mm. The average measurement at the apical foramen with LAE Propex Pixi was 18.68 mm and at the anatomical foramen it was 19.10 mm. The average measurement at the apical foramen with LAE YS-RZ-A was 18.50 mm and at the anatomical foramen it was 19.10 mm. In none of the cases did the Electronic Apical Locators exceed the apical foramen. There is a significant difference between the measurement at the apical foramen with the LAE Propex Pixi and the anatomical apical foramen (p=0.000). There is a significant difference between the measurement at the apical foramen with the LAE YS-RZ-A and the anatomical apical foramen (p=0.000). There are no significant differences between the conductometrics obtained with LAE Propex Pixi and YS-RZ-A (p=0.763).La finalidad de este trabajo de investigación fue la comparación de la conductometría con el localizador apical electrónico Propex Pixi y el localizador apical YS-RZ-A. El tipo de investigación fue cuantitativa, el diseño cuasi-experimental, descriptivo comparativo, transversal. La muestra fue conformada por 20 dientes premolares. Los resultados destacados fueron: El promedio de las medidas de conductometría con Propex Pixi fue 17,68 mm. El promedio de las medidas de conductometría con YS-RZ-A fue 17,50 mm. La conductometría más frecuente con LAE Propex Pixi fue 16,00 mm; seguido de 19,50 mm. La conductometría más frecuente con LAE YS-RZ-A fue 17,00 mm; 18,00 mm y 19,00 mm. El promedio de medidas al foramen apical con LAE Propex Pixi fue 18,68 mm y al anatómico fue 19,10 mm. El promedio de medidas al foramen apical con LAE YS-RZ-A fue 18,50 mm y al anatómico fue 19,10 mm. En ninguno de los casos los Localizadores Apicales Electrónicos sobrepasaron el foramen apical. Existe diferencia significativa entre la medida al foramen apical con el LAE Propex Pixi y el foramen apical anatómico (p=0,000). Existe diferencia significativa entre la medida al foramen apical con el LAE YS-RZ-A y el foramen apical anatómico (p=0,000). No existe diferencias significativas entre las conductometrías obtenidas con LAE Propex Pixi y YS-RZ-A (p=0,763).application/pdfspaUniversidad Nacional de la Amazonía PeruanaPEinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/ConductometríaDiente premolarÁpice del dientehttp://purl.org/pe-repo/ocde/ford#3.02.14Conductometría con el localizador apical electrónico propex pixi y el localizador apical YS-RZ-Ainfo:eu-repo/semantics/bachelorThesisreponame:UNAPIquitos-Institucionalinstname:Universidad Nacional De La Amazonía Peruanainstacron:UNAPIquitosSUNEDUOdontologíaUniversidad Nacional de la Amazonía Peruana. Facultad de OdontologíaCirujano Dentista7862752175560135https://orcid.org/0000-0002-1632-082121522076https://purl.org/pe-repo/renati/type#tesis911026https://purl.org/pe-repo/renati/level#tituloProfesionalBardales Ríos, Jorge FranciscoPanduro Del Castillo, Myriam Betty|Camiñas Gómez, Lina MarliORIGINALCaroline_Tesis_Titulo_2022.pdfCaroline_Tesis_Titulo_2022.pdfTexto completoapplication/pdf762836https://demo7-repo.unapiquitos.edu.pe/bitstreams/86f61381-0fa3-458a-979f-cf02f5d44400/downloada06b07fa5f304ac6fd806af228c2b16bMD51trueAnonymousREADTEXTCaroline_Tesis_Titulo_2022.pdf.txtCaroline_Tesis_Titulo_2022.pdf.txtExtracted texttext/plain39704https://demo7-repo.unapiquitos.edu.pe/bitstreams/0c240acb-7d8d-40fc-8aa2-5b7a31d1e181/download7d3b33c232411f7a4c1fc9727d4c7661MD52falseAnonymousREADTHUMBNAILCaroline_Tesis_Titulo_2022.pdf.jpgCaroline_Tesis_Titulo_2022.pdf.jpgGenerated Thumbnailimage/jpeg3127https://demo7-repo.unapiquitos.edu.pe/bitstreams/4cd97529-fc81-4e47-b651-52dc55d8d1ef/download2075821e1037e8f23f9bc8f4102490e3MD53falseAnonymousREAD20.500.12737/8080oai:demo7-repo.unapiquitos.edu.pe:20.500.12737/80802025-08-08T18:17:09.160054Zhttps://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessopen.accesshttps://demo7-repo.unapiquitos.edu.peRepositorio Digital UNAPrepositorio.institucional@unapiquitos.edu.pe |
score |
13.072484 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).