Evaluation of dimethylacetamide and dimethylformamide as cryoprotectants for epididymal alpaca sperm (Vicugna pacos)
Descripción del Articulo
The aim of this study was to determine the effect of the type (dimethylacetamide [DMA] and dimethylformamide [DMF]) and concentrations (1, 3.5, 7%) of cryoprotective agents on three sperm parameters during the cryopreservation process of epididymal alpaca sperm. A 2x3 factorial design consisting of...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/17548 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/17548 |
Nivel de acceso: | acceso abierto |
Materia: | Vicugna pacos cryopreservation spermatozoa epididymis dimethylacetamide dimethylformamide cytometry criopreservación espermatozoides epidídimo dimetilacetamida dimetilformamida citometría |
Sumario: | The aim of this study was to determine the effect of the type (dimethylacetamide [DMA] and dimethylformamide [DMF]) and concentrations (1, 3.5, 7%) of cryoprotective agents on three sperm parameters during the cryopreservation process of epididymal alpaca sperm. A 2x3 factorial design consisting of the two cryoprotectants and the three concentrations was used. The parameters of sperm viability (SYBR-14/PI) and mitochondrial membrane potential (MitoTracker Deep Red FM) of sperm of 40 epididymis were evaluated by flow cytometry and motility by microscopy after thawing. 111/5000. A higher percentage of motility after thawing was found with AMD (14%) than with DMF (10%) (p=0.001). In addition, there was a significant effect of the cryoprotectant concentration in all the parameters evaluated (p<0.001), being better at concentrations of 1 and 3.5% than with 7%. No significant effect of the cryoprotectant-concentration interaction was found. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).