Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study
Descripción del Articulo
The optimal selection of orthodontic archwires allows the professional to make the treatment in an efficient way; therefore, the knowledge of basic mechanical properties is required, which are not revealed by their manufacturers. The purpose of this study was to compare the mechanical properties (co...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2010 |
| Institución: | Universidad Nacional Mayor de San Marcos |
| Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
| Lenguaje: | español |
| OAI Identifier: | oai:ojs.csi.unmsm:article/2833 |
| Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2833 |
| Nivel de acceso: | acceso abierto |
| Materia: | Alambres para ortodoncia Ensayo de materiales Resistencia a la tracción Estudio comparativo. Orthodontic archwires Material assay Traction resistance Comparative study. |
| id |
REVUNMSM_b87324358a707572047e127d1be9bca1 |
|---|---|
| oai_identifier_str |
oai:ojs.csi.unmsm:article/2833 |
| network_acronym_str |
REVUNMSM |
| network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository_id_str |
|
| dc.title.none.fl_str_mv |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study Propiedades mecánicas de tres marcas de arcos ortodóncicos de níquel-titanio termoactivados. Estudio in vitro |
| title |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study |
| spellingShingle |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study Ramos Torres, Viviana Alambres para ortodoncia Ensayo de materiales Resistencia a la tracción Estudio comparativo. Orthodontic archwires Material assay Traction resistance Comparative study. |
| title_short |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study |
| title_full |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study |
| title_fullStr |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study |
| title_full_unstemmed |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study |
| title_sort |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro Study |
| dc.creator.none.fl_str_mv |
Ramos Torres, Viviana Soldevilla Galarza, Luciano Mattos Vela, Manuel |
| author |
Ramos Torres, Viviana |
| author_facet |
Ramos Torres, Viviana Soldevilla Galarza, Luciano Mattos Vela, Manuel |
| author_role |
author |
| author2 |
Soldevilla Galarza, Luciano Mattos Vela, Manuel |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Alambres para ortodoncia Ensayo de materiales Resistencia a la tracción Estudio comparativo. Orthodontic archwires Material assay Traction resistance Comparative study. |
| topic |
Alambres para ortodoncia Ensayo de materiales Resistencia a la tracción Estudio comparativo. Orthodontic archwires Material assay Traction resistance Comparative study. |
| description |
The optimal selection of orthodontic archwires allows the professional to make the treatment in an efficient way; therefore, the knowledge of basic mechanical properties is required, which are not revealed by their manufacturers. The purpose of this study was to compare the mechanical properties (constant tension in the activation area, constant elongation in the activation area, maximum resistance and break point) of three thermo-activated titanium-nickel orthodontic archwires. 10 0.4 mm-diameter thermo-activated titaniumnickel orthodontic archwires from the following brands were used: NiTi GACR (Control Group), Nitinol Termoactivado 3M UnitekR, Sentalloy GACR, Nitinol Termoactivado TECNIDENTR. 80 mm test bodies were prepared and tested for traction using a Zwick / Roell machine model Z050 8402 with a 50 kN capacity, at a speed of 1 mm/min and at 37 °C. The results show that the higher value was obtained by Nitinol 3M Unitek (374,43 + 16,72 MPa) for the constant tension in the activation area, while the Nitinol Tecnident showed the higher value (14,51 + 0,91%) in the constant elongation in the activation area. The Nitinol Sentalloy GAC recorded the higher value in the maximum resistance (1398,59 + 45,36 MPa) and break point (174,29 + 6,47 N). It was concluded that the thermo-activated titanium-nickel orthodontic archwires present differences in their mechanical properties. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010-07-15 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2833 10.15381/os.v13i1.2833 |
| url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2833 |
| identifier_str_mv |
10.15381/os.v13i1.2833 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2833/2422 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2010 Viviana Ramos Torres, Luciano Soldevilla Galarza, Manuel Mattos Vela https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2010 Viviana Ramos Torres, Luciano Soldevilla Galarza, Manuel Mattos Vela https://creativecommons.org/licenses/by-nc-sa/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Odontología |
| publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Odontología |
| dc.source.none.fl_str_mv |
Odontología Sanmarquina; Vol. 13 No. 1 (2010); 23-27 Odontología Sanmarquina; Vol. 13 Núm. 1 (2010); 23-27 1609-8617 1560-9111 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
| instname_str |
Universidad Nacional Mayor de San Marcos |
| instacron_str |
UNMSM |
| institution |
UNMSM |
| reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| collection |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1795238207966674944 |
| spelling |
Mechanicals properties from three thermo-activated titanium-nickel orthodontic archwire brands. In vitro StudyPropiedades mecánicas de tres marcas de arcos ortodóncicos de níquel-titanio termoactivados. Estudio in vitroRamos Torres, VivianaSoldevilla Galarza, LucianoMattos Vela, ManuelAlambres para ortodonciaEnsayo de materialesResistencia a la tracciónEstudio comparativo.Orthodontic archwiresMaterial assayTraction resistanceComparative study.The optimal selection of orthodontic archwires allows the professional to make the treatment in an efficient way; therefore, the knowledge of basic mechanical properties is required, which are not revealed by their manufacturers. The purpose of this study was to compare the mechanical properties (constant tension in the activation area, constant elongation in the activation area, maximum resistance and break point) of three thermo-activated titanium-nickel orthodontic archwires. 10 0.4 mm-diameter thermo-activated titaniumnickel orthodontic archwires from the following brands were used: NiTi GACR (Control Group), Nitinol Termoactivado 3M UnitekR, Sentalloy GACR, Nitinol Termoactivado TECNIDENTR. 80 mm test bodies were prepared and tested for traction using a Zwick / Roell machine model Z050 8402 with a 50 kN capacity, at a speed of 1 mm/min and at 37 °C. The results show that the higher value was obtained by Nitinol 3M Unitek (374,43 + 16,72 MPa) for the constant tension in the activation area, while the Nitinol Tecnident showed the higher value (14,51 + 0,91%) in the constant elongation in the activation area. The Nitinol Sentalloy GAC recorded the higher value in the maximum resistance (1398,59 + 45,36 MPa) and break point (174,29 + 6,47 N). It was concluded that the thermo-activated titanium-nickel orthodontic archwires present differences in their mechanical properties.La selección óptima de los alambres ortodóncicos permite al profesional realizar el tratamiento de manera eficiente; por ello, se requiere el conocimiento de las propiedades mecánicas básicas, las cuales no son reveladas por sus fabricantes. El estudio tuvo como objetivo comparar las propiedades mecánicas (tensión en la zona de activación constante, elongación en la zona de activación constante, resistencia máxima y límite de ruptura) de tres marcas de alambres ortodóncicos de níquel-titanio termoactivados. Se usaron 10 arcos ortodóncicos de níquel-titanio termoactivados de 0,4 mm de diámetro de las marcas: NiTi GACR (Grupo Control), Nitinol Termoactivado 3M UnitekR, Sentalloy GACR, Nitinol Termoactivado TECNIDENTR. Se prepararon cuerpos de prueba de 80 mm y fueron sometidos a ensayos de tracción utilizando una máquina Zwick / Roell modelo Z050 8402 de 50 kN de capacidad, a una velocidad de 1 mm/min y a 37 ºC. Los resultados muestran el mayor valor fue obtenido por Nitinol 3M Unitek (374,43 + 16,72 MPa) para la tensión en la zona de activación constante, mientras que Nitinol Tecnident mostró el mayor valor (14,51 + 0,91%) en la elongación en la zona de activación constante, el Nitinol Sentalloy GAC registró el mayor valor en la resistencia máxima (1398,59 + 45,36 MPa) y límite de ruptura (174,29 + 6,47 N). Se concluye que los alambres ortodóncicos de níquel-titanio termoactivados, presentan diferencias en sus propiedades mecánicas.Universidad Nacional Mayor de San Marcos, Facultad de Odontología2010-07-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/283310.15381/os.v13i1.2833Odontología Sanmarquina; Vol. 13 No. 1 (2010); 23-27Odontología Sanmarquina; Vol. 13 Núm. 1 (2010); 23-271609-86171560-9111reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2833/2422Derechos de autor 2010 Viviana Ramos Torres, Luciano Soldevilla Galarza, Manuel Mattos Velahttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/28332020-03-23T18:34:19Z |
| score |
13.924177 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).