Box - Behnken design to optimize the performance of a peak photovoltaic solar system

Descripción del Articulo

The objective of the research was to design a Box Behnken system to optimize the performance of a peak photovoltaic solar system in the Mantaro Valley under conditions of high population density. For this, the system was located in a zone of moderate urban density in the city of Huancayo, Junín regi...

Descripción completa

Detalles Bibliográficos
Autores: Delzo Salomé, Armando Siles, Huari Vila, Oscar Paul, Salazar Mercado, Jorge Edgar, Casimiro Soriano, Enzo Martin
Formato: artículo
Fecha de Publicación:2021
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/1018
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/1018
Nivel de acceso:acceso abierto
Materia:Sistema solar fotovoltaico
Box-Behnken
efectos normales
superficie de respuesta
Photovoltaic solar system
normal effects
response surface
id REVUNI_d2f80ff90a7e38411dcef9f53b7a2bfa
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/1018
network_acronym_str REVUNI
network_name_str Revistas - Universidad Nacional de Ingeniería
repository_id_str
spelling Box - Behnken design to optimize the performance of a peak photovoltaic solar systemDiseño box – Behnken para optimizar el rendimiento de un pico sistema solar fotovoltaicoDelzo Salomé, Armando SilesHuari Vila, Oscar PaulSalazar Mercado, Jorge EdgarCasimiro Soriano, Enzo MartinSistema solar fotovoltaicoBox-Behnkenefectos normalessuperficie de respuestaPhotovoltaic solar systemBox-Behnkennormal effectsresponse surfaceThe objective of the research was to design a Box Behnken system to optimize the performance of a peak photovoltaic solar system in the Mantaro Valley under conditions of high population density. For this, the system was located in a zone of moderate urban density in the city of Huancayo, Junín region, in the central region of Peru with coordinates 12 ° 03'29.0 "S 75 ° 13'12.9" W. Measurements were made in the regional summer season. The variables evaluated for optimization in the Behnken Box Design were: orientation, angle of inclination of the solar panel and time of exposure. Behavior was modeled using the response surface for single and combined variables, comparing the variation in the potential difference (V). The results showed that the variable of greatest significance for the potential variation was the angle of inclination, with a standardized effect of 3.48 and 95% significance. All the residuals of the factorial diagram were found within +0.8 and -0.8, indicating that the experimental procedure applying the Box Behnken method did not present outliers. It was concluded that it is possible to maximize the potential difference of a solar collection system in the Mantaro Valley, in an area of ​​high urban density, prioritizing the angle of incidence of radiation.El objetivo de la investigación fue diseñar un sistema Box Behnken para optimizar el rendimiento de un pico sistema solar fotovoltaico en el Valle del Mantaro en condiciones de alta densidad poblacional. Para ello se ubicó el sistema en una zona de moderada densidad urbana de la ciudad de Huancayo, región Junín, en la región central del Perú con coordenadas 12°03'29,0"S 75°13'12,9"W. Las mediciones se realizaron en la temporada de verano regional. Las variables evaluadas para su optimización en el Diseño Box Behnken fueron: orientación, ángulo de inclinación del panel solar y la hora de exposición. Se modeló el comportamiento mediante la superficie de respuesta para variables únicas y combinadas, comparándose la variación en la diferencia de potencial (V). Los resultados mostraron que la variable de mayor significación para la variación de potencial fue el ángulo de inclinación, con un efecto estandarizado de 3,48 y 95% de significancia. Todos los residuos del diagrama factorial se encontraron dentro de +0,8 y -0,8, indicando que el procedimiento experimental aplicando el método Box Behnken no presentó valores atípicos. Se concluyó que es posible maximizar la diferencia de potencial de un sistema de captación solar en el Valle del Mantaro, en una zona de alta densidad urbana, priorizando el ángulo de incidencia de radiación.Universidad Nacional de Ingeniería2021-07-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/101810.21754/tecnia.v21i2.1018TECNIA; Vol. 31 No. 2 (2021); 97-101TECNIA; Vol. 31 Núm. 2 (2021); 97-1012309-04130375-776510.21754/tecnia.v31i2reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/1018/1749Derechos de autor 2021 TECNIAinfo:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/10182025-07-15T00:11:02Z
dc.title.none.fl_str_mv Box - Behnken design to optimize the performance of a peak photovoltaic solar system
Diseño box – Behnken para optimizar el rendimiento de un pico sistema solar fotovoltaico
title Box - Behnken design to optimize the performance of a peak photovoltaic solar system
spellingShingle Box - Behnken design to optimize the performance of a peak photovoltaic solar system
Delzo Salomé, Armando Siles
Sistema solar fotovoltaico
Box-Behnken
efectos normales
superficie de respuesta
Photovoltaic solar system
Box-Behnken
normal effects
response surface
title_short Box - Behnken design to optimize the performance of a peak photovoltaic solar system
title_full Box - Behnken design to optimize the performance of a peak photovoltaic solar system
title_fullStr Box - Behnken design to optimize the performance of a peak photovoltaic solar system
title_full_unstemmed Box - Behnken design to optimize the performance of a peak photovoltaic solar system
title_sort Box - Behnken design to optimize the performance of a peak photovoltaic solar system
dc.creator.none.fl_str_mv Delzo Salomé, Armando Siles
Huari Vila, Oscar Paul
Salazar Mercado, Jorge Edgar
Casimiro Soriano, Enzo Martin
author Delzo Salomé, Armando Siles
author_facet Delzo Salomé, Armando Siles
Huari Vila, Oscar Paul
Salazar Mercado, Jorge Edgar
Casimiro Soriano, Enzo Martin
author_role author
author2 Huari Vila, Oscar Paul
Salazar Mercado, Jorge Edgar
Casimiro Soriano, Enzo Martin
author2_role author
author
author
dc.subject.none.fl_str_mv Sistema solar fotovoltaico
Box-Behnken
efectos normales
superficie de respuesta
Photovoltaic solar system
Box-Behnken
normal effects
response surface
topic Sistema solar fotovoltaico
Box-Behnken
efectos normales
superficie de respuesta
Photovoltaic solar system
Box-Behnken
normal effects
response surface
description The objective of the research was to design a Box Behnken system to optimize the performance of a peak photovoltaic solar system in the Mantaro Valley under conditions of high population density. For this, the system was located in a zone of moderate urban density in the city of Huancayo, Junín region, in the central region of Peru with coordinates 12 ° 03'29.0 "S 75 ° 13'12.9" W. Measurements were made in the regional summer season. The variables evaluated for optimization in the Behnken Box Design were: orientation, angle of inclination of the solar panel and time of exposure. Behavior was modeled using the response surface for single and combined variables, comparing the variation in the potential difference (V). The results showed that the variable of greatest significance for the potential variation was the angle of inclination, with a standardized effect of 3.48 and 95% significance. All the residuals of the factorial diagram were found within +0.8 and -0.8, indicating that the experimental procedure applying the Box Behnken method did not present outliers. It was concluded that it is possible to maximize the potential difference of a solar collection system in the Mantaro Valley, in an area of ​​high urban density, prioritizing the angle of incidence of radiation.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-25
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/1018
10.21754/tecnia.v21i2.1018
url https://revistas.uni.edu.pe/index.php/tecnia/article/view/1018
identifier_str_mv 10.21754/tecnia.v21i2.1018
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/1018/1749
dc.rights.none.fl_str_mv Derechos de autor 2021 TECNIA
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2021 TECNIA
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol. 31 No. 2 (2021); 97-101
TECNIA; Vol. 31 Núm. 2 (2021); 97-101
2309-0413
0375-7765
10.21754/tecnia.v31i2
reponame:Revistas - Universidad Nacional de Ingeniería
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str Revistas - Universidad Nacional de Ingeniería
collection Revistas - Universidad Nacional de Ingeniería
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1838636204298338304
score 13.955691
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).