Effect of magnetic field in hard water treatment
Descripción del Articulo
Magnetic Water treatment is know for over a century, even though, actually no one knows exactly how it works. One of the naim applications is to suppress water-scale deposition on the inner surface of boilers, heat exchangers and pipelines. In the paper we report some experiments concerning the e...
| Autores: | , , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 1998 |
| Institución: | Universidad Nacional de Ingeniería |
| Repositorio: | Revistas - Universidad Nacional de Ingeniería |
| Lenguaje: | español |
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/417 |
| Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/417 |
| Nivel de acceso: | acceso abierto |
| id |
REVUNI_667f5377e4549d4dea26a93ae01c7806 |
|---|---|
| oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/417 |
| network_acronym_str |
REVUNI |
| network_name_str |
Revistas - Universidad Nacional de Ingeniería |
| repository_id_str |
|
| spelling |
Effect of magnetic field in hard water treatmentEfecto de campo magnético en el tratamiento de aguas durasZavaleta, MeryValera, AníbalRivas, EnriqueMendoza, AtilioTinoco, Soledad Magnetic Water treatment is know for over a century, even though, actually no one knows exactly how it works. One of the naim applications is to suppress water-scale deposition on the inner surface of boilers, heat exchangers and pipelines. In the paper we report some experiments concerning the effectivity of the magnetic treatment in the reduction of water scale deposition. The applied diagnostic methods were: Observation of the turbidity factor (Tyndall efect). Cristallographic observations under polarized light. structural measurements (Debye-Scherrer spectra) and chemical composition. El efecto del campo magnético sobre aguas duras ha sido reconocido por cerca de 100 años, no obstante, el mecanismo del mismo es aún desconocido. Una de las principales aplicaciones es la de suprimir las incrustaciones dentro de calderos, intercambiadores de calor y ductos de transmisión. En este artículo, reportamos una serie de experimentos de Laboratorio concernientes al efecto positivo del tratamiento magnético de aguas duras. Los principales métodos de diagnósticos empleados fueron: Observaciones del factor de turbiedad (Efecto Tyndall). Observaciones cristalográficas bajo luz polarizada, estructural (espectros Debye-Scherrer) y análisis químico. Universidad Nacional de Ingeniería1998-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/41710.21754/tecnia.v9i1.417TECNIA; Vol. 9 No. 1 (1998)TECNIA; Vol. 9 Núm. 1 (1998)2309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/417/303Derechos de autor 1998 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/4172023-11-29T21:34:12Z |
| dc.title.none.fl_str_mv |
Effect of magnetic field in hard water treatment Efecto de campo magnético en el tratamiento de aguas duras |
| title |
Effect of magnetic field in hard water treatment |
| spellingShingle |
Effect of magnetic field in hard water treatment Zavaleta, Mery |
| title_short |
Effect of magnetic field in hard water treatment |
| title_full |
Effect of magnetic field in hard water treatment |
| title_fullStr |
Effect of magnetic field in hard water treatment |
| title_full_unstemmed |
Effect of magnetic field in hard water treatment |
| title_sort |
Effect of magnetic field in hard water treatment |
| dc.creator.none.fl_str_mv |
Zavaleta, Mery Valera, Aníbal Rivas, Enrique Mendoza, Atilio Tinoco, Soledad |
| author |
Zavaleta, Mery |
| author_facet |
Zavaleta, Mery Valera, Aníbal Rivas, Enrique Mendoza, Atilio Tinoco, Soledad |
| author_role |
author |
| author2 |
Valera, Aníbal Rivas, Enrique Mendoza, Atilio Tinoco, Soledad |
| author2_role |
author author author author |
| description |
Magnetic Water treatment is know for over a century, even though, actually no one knows exactly how it works. One of the naim applications is to suppress water-scale deposition on the inner surface of boilers, heat exchangers and pipelines. In the paper we report some experiments concerning the effectivity of the magnetic treatment in the reduction of water scale deposition. The applied diagnostic methods were: Observation of the turbidity factor (Tyndall efect). Cristallographic observations under polarized light. structural measurements (Debye-Scherrer spectra) and chemical composition. |
| publishDate |
1998 |
| dc.date.none.fl_str_mv |
1998-06-01 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/417 10.21754/tecnia.v9i1.417 |
| url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/417 |
| identifier_str_mv |
10.21754/tecnia.v9i1.417 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/417/303 |
| dc.rights.none.fl_str_mv |
Derechos de autor 1998 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 1998 TECNIA http://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| dc.source.none.fl_str_mv |
TECNIA; Vol. 9 No. 1 (1998) TECNIA; Vol. 9 Núm. 1 (1998) 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
| instname_str |
Universidad Nacional de Ingeniería |
| instacron_str |
UNI |
| institution |
UNI |
| reponame_str |
Revistas - Universidad Nacional de Ingeniería |
| collection |
Revistas - Universidad Nacional de Ingeniería |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1833562777401163776 |
| score |
13.936249 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).