Comparison of the precision of two electronic apical locators in teeth with simulated perforations
Descripción del Articulo
        Objective: The purpose of the study was to compare the precision of the Propex Pixi and Raypex 6 electronic apical locators in determining the working length of teeth with simulated perforations at different levels of the root canal. Materials and Methods: 36 uniradicular lower premolars were used w...
              
            
    
                        | Autores: | , , | 
|---|---|
| Formato: | artículo | 
| Fecha de Publicación: | 2021 | 
| Institución: | Universidad Científica del Sur | 
| Repositorio: | Revistas - Universidad Científica del Sur | 
| Lenguaje: | español | 
| OAI Identifier: | oai:revistas.cientifica.edu.pe:article/909 | 
| Enlace del recurso: | https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/909 | 
| Nivel de acceso: | acceso abierto | 
| Materia: | endodoncia dientes premolares alginato apice del diente endodontics alginates premolar tooth tooth apex | 
| Sumario: | Objective: The purpose of the study was to compare the precision of the Propex Pixi and Raypex 6 electronic apical locators in determining the working length of teeth with simulated perforations at different levels of the root canal. Materials and Methods: 36 uniradicular lower premolars were used with a canal randomly divided into three groups of 12 teeth each. In the first group two simulated perforations were made at the middle and apical level. In the second group a simulated cervical perforation was made, and in the third group a simulated perforation was performed at the apical level. Two electronic apical locators Propex Pixi and Raypex 6 were used, and the real length of the canal was measured with a digital Vernier caliper. Descriptive and inferential statistics were applied with the Friedman test at a confidence level of 95%. Results: When comparing the precision of the lengths obtained by the Propex Pixi and Raypex 6 apical electronic locators, statistically significant differences were found in the real length of the canal (p= 0.006) between simulated perforation of lower premolars at the cervical (p<0.001) and the apical level (p=0.008), Conclusion: The Propex Pixi apical electronic locator (Dentsply Maillefer - Germany) presented greater precision in the determination of the real canal length in teeth with simulated perforations at different levels of the root canal. | 
|---|
 Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
    La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
 
   
   
             
            