A rapid, sensitive, precise and accurate High Performance Liquid Chromatography method was developed and validated for the determination of N-3-methoxybenzyl-linoleamide levels in Sprague Dawley rat brain. During sample preparation, acetonitrile was used as extraction solvent and N-benzyl-palmitamid...

Descripción completa

Detalles Bibliográficos
Autores: Rodrigo Moscoso Palacios, Maria Aranzamendi Zenteno, Julitza Paredes Fuentes, José Carpio Carpio, José Villanueva Salas, Karin Vera López, Rita Nieto Montesinos
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad Católica de Santa María
Repositorio:Revistas - Universidad Católica de Santa María
Lenguaje:español
OAI Identifier:oai:ojs.revistas.ucsm.edu.pe:article/264
Enlace del recurso:https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/264
Nivel de acceso:acceso abierto
Materia:N-3-metoxibencil-linoleamida
homogenizado de cerebro de rata
HPLC y validación
id REVUCSM_0552dbcdb467b7e61804bcda65794b95
oai_identifier_str oai:ojs.revistas.ucsm.edu.pe:article/264
network_acronym_str REVUCSM
network_name_str Revistas - Universidad Católica de Santa María
repository_id_str
spelling Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography Desarrollo y validación de un método analítico para la determinación de N-3-metoxibencil-linoleamida en homogenizado de cerebro de ratas Sprague Dawley por Cromatografía líquida de alta resoluciónRodrigo Moscoso PalaciosMaria Aranzamendi ZentenoJulitza Paredes FuentesJosé Carpio CarpioJosé Villanueva SalasKarin Vera LópezRita Nieto MontesinosN-3-metoxibencil-linoleamidahomogenizado de cerebro de rataHPLC y validaciónA rapid, sensitive, precise and accurate High Performance Liquid Chromatography method was developed and validated for the determination of N-3-methoxybenzyl-linoleamide levels in Sprague Dawley rat brain. During sample preparation, acetonitrile was used as extraction solvent and N-benzyl-palmitamide as internal standard. The analyte was separated on a Chromolith® Performance column with isocratic elution of acetonitrile-ultrapure water (80:20, v/v) at 1.0 mL/min and 40°C. Detection was performed using a diode array detector at a wavelength of 205 nm. The selectivity of the method was confirmed by the absence of interferences from endogenous compounds. The developed method was used to construct linear calibration curves over the concentration range of 250 and 10 000 ng/mL (R2 ≥ 0.9900). Using 500 μg of brain homogenate, the validated lower limit of quantification was 250.0 ng/mL. Intra- and inter-day accuracy and precision were within 15% of nominal concentrations. Likewise, the analyte and its internal standard proved to be stable during storage, sample preparation and chromatographic analysis.Un método rápido, sensible y preciso por Cromatografía Líquida de Alta Resolución fue desarrollado y validado para la determinación de los niveles de N-3-metoxibencil-linoleamida en cerebro de ratas Sprague Dawley. Durante la preparación de la muestra se usó acetonitrilo como solvente de extracción y N-bencil-palmitamida como estándar interno. El analito se separó en una columna Chromolith® Performance con elución isocrática de acetonitrilo-agua ultrapura (80:20, v/v) a 1.0 mL/min y a 40°C. La detección se realizó utilizando un detector de arreglo de diodos a una longitud de onda de 205 nm. La selectividad del método se confirmó por la ausencia de interferentes endógenos. El método desarrollado se usó para construir curvas de calibración lineales en el rango de concentración de 250 y 10 000 ng/mL, (R2 ≥ 0.9900). Usando 500 μg de homogeneizado de cerebro, el límite inferior de cuantificación validado fue de 250.0 ng/mL. La exactitud y precisión intra e inter-día estuvieron dentro del 15% de las concentraciones nominales. Asimismo, el analito y su estándar interno demostraron ser estables durante el almacenamiento, la preparación de muestra y el análisis cromatográfico.Universidad Católica de Santa María2020-01-17info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/26410.35286/veritas.v21i1.264Veritas; Vol. 21 Núm. 1 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 89-94Veritas; Vol. 21 Núm. 1 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 89-94Veritas; Vol. 21 Núm. 1 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 89-941684-78221684-782210.35286/veritas.v21i1reponame:Revistas - Universidad Católica de Santa Maríainstname:Universidad Católica de Santa Maríainstacron:UCSMspahttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/264/186Derechos de autor 2020 Veritasinfo:eu-repo/semantics/openAccessoai:ojs.revistas.ucsm.edu.pe:article/2642021-07-13T05:25:28Z
dc.title.none.fl_str_mv Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
Desarrollo y validación de un método analítico para la determinación de N-3-metoxibencil-linoleamida en homogenizado de cerebro de ratas Sprague Dawley por Cromatografía líquida de alta resolución

title Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
spellingShingle Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
Rodrigo Moscoso Palacios
N-3-metoxibencil-linoleamida
homogenizado de cerebro de rata
HPLC y validación
title_short Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
title_full Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
title_fullStr Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
title_full_unstemmed Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
title_sort Development and validation of an analytical method for the determination of N-3-methoxybenzyllinoleamide in brain homogenate of Sprague Dawley rats by High Performance Liquid Chromatography
dc.creator.none.fl_str_mv Rodrigo Moscoso Palacios
Maria Aranzamendi Zenteno
Julitza Paredes Fuentes
José Carpio Carpio
José Villanueva Salas
Karin Vera López
Rita Nieto Montesinos
author Rodrigo Moscoso Palacios
author_facet Rodrigo Moscoso Palacios
Maria Aranzamendi Zenteno
Julitza Paredes Fuentes
José Carpio Carpio
José Villanueva Salas
Karin Vera López
Rita Nieto Montesinos
author_role author
author2 Maria Aranzamendi Zenteno
Julitza Paredes Fuentes
José Carpio Carpio
José Villanueva Salas
Karin Vera López
Rita Nieto Montesinos
author2_role author
author
author
author
author
author
dc.subject.none.fl_str_mv N-3-metoxibencil-linoleamida
homogenizado de cerebro de rata
HPLC y validación
topic N-3-metoxibencil-linoleamida
homogenizado de cerebro de rata
HPLC y validación
description A rapid, sensitive, precise and accurate High Performance Liquid Chromatography method was developed and validated for the determination of N-3-methoxybenzyl-linoleamide levels in Sprague Dawley rat brain. During sample preparation, acetonitrile was used as extraction solvent and N-benzyl-palmitamide as internal standard. The analyte was separated on a Chromolith® Performance column with isocratic elution of acetonitrile-ultrapure water (80:20, v/v) at 1.0 mL/min and 40°C. Detection was performed using a diode array detector at a wavelength of 205 nm. The selectivity of the method was confirmed by the absence of interferences from endogenous compounds. The developed method was used to construct linear calibration curves over the concentration range of 250 and 10 000 ng/mL (R2 ≥ 0.9900). Using 500 μg of brain homogenate, the validated lower limit of quantification was 250.0 ng/mL. Intra- and inter-day accuracy and precision were within 15% of nominal concentrations. Likewise, the analyte and its internal standard proved to be stable during storage, sample preparation and chromatographic analysis.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-17
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/264
10.35286/veritas.v21i1.264
url https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/264
identifier_str_mv 10.35286/veritas.v21i1.264
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/264/186
dc.rights.none.fl_str_mv Derechos de autor 2020 Veritas
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2020 Veritas
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Católica de Santa María
publisher.none.fl_str_mv Universidad Católica de Santa María
dc.source.none.fl_str_mv Veritas; Vol. 21 Núm. 1 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 89-94
Veritas; Vol. 21 Núm. 1 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 89-94
Veritas; Vol. 21 Núm. 1 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 89-94
1684-7822
1684-7822
10.35286/veritas.v21i1
reponame:Revistas - Universidad Católica de Santa María
instname:Universidad Católica de Santa María
instacron:UCSM
instname_str Universidad Católica de Santa María
instacron_str UCSM
institution UCSM
reponame_str Revistas - Universidad Católica de Santa María
collection Revistas - Universidad Católica de Santa María
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1846698422795501568
score 13.0768795
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).