EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS
Descripción del Articulo
The objective of this research was to determine the efficiency of the laminar and conventional sedimentation system to eliminate different concentrations of suspended solids, for which different physicochemical parameters were taken into account (temperature, pH, turbidity, dissolved oxygen and dry...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2020 |
| Institución: | Sociedad Química del Perú |
| Repositorio: | Revista de la Sociedad Química del Perú |
| Lenguaje: | español |
| OAI Identifier: | oai:rsqp.revistas.sqperu.org.pe:article/194 |
| Enlace del recurso: | http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/194 |
| Nivel de acceso: | acceso abierto |
| Materia: | sedimentation efficiency sedimentable solids flocculation laminar sedimentation conventional sedimentation sedimentación eficiencia sólidos sedimentables floculación sedimentador laminar sedimentador convencional |
| id |
REVSQP_7252c0d63222887bea5be305ba66a112 |
|---|---|
| oai_identifier_str |
oai:rsqp.revistas.sqperu.org.pe:article/194 |
| network_acronym_str |
REVSQP |
| network_name_str |
Revista de la Sociedad Química del Perú |
| repository_id_str |
|
| spelling |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDSEFICIENCIA DE UN SEDIMENTADOR LAMINAR Y CONVENCIONAL PARA ELIMINAR SÓLIDOSGuerrero Vejarano, Tania E.Salazar Álvarez, Juan C.Paredes Salazar, José L.sedimentationefficiencysedimentable solidsflocculationlaminar sedimentationconventional sedimentationsedimentacióneficienciasólidos sedimentablesfloculaciónsedimentador laminarsedimentador convencionalThe objective of this research was to determine the efficiency of the laminar and conventional sedimentation system to eliminate different concentrations of suspended solids, for which different physicochemical parameters were taken into account (temperature, pH, turbidity, dissolved oxygen and dry residue). To determine the physicochemical parameters, water samples were prepared at different concentrations (1, 2 and 3%) of solids, which were analyzed at the inlet and outlet of the settler, in treatments with coagulant and without coagulant, with three repetitions at each treatment. To determine which of the sedimentation was more efficient, analysis of variance and Tukey test of the evaluated factors (type of settler, coagulant and concentration of solids) were performed, obtaining as a result significant differences between both settlings withEl presente trabajo de investigación tuvo como objetivo determinar la eficiencia del sedimentador laminar y convencional para eliminar diferentes concentraciones de sólidos en suspensión, para ello se tomaron en cuenta diferentes parámetros fisicoquímicos (temperatura, pH, turbiedad, oxígeno disuelto y residuo seco). Para determinar los parámetros fisicoquímicos se prepararon muestras de agua a diferentes concentraciones (1, 2 y 3 %) de sólidos, las cuales se analizaron a la entrada y salida de los sedimentadores, en tratamientos con coagulante y sin coagulante, con tres repeticiones a cada tratamiento. Para determinar cuál de los sedimentadores fue más eficiente, se realizó el análisis de varianza y prueba de Tukey de los factores evaluados (tipo de sedimentador, coagulante y concentración de sólidos), obteniéndose como resultado diferencias significativas entre ambos sedimentadores con respecto al tipo de concentración y según el tratamiento con coagulante o sin coagulante, llegando a la conclusión que el sedimentador laminar tiene una eficiencia de 93,85 %, siendo más eficiente que el convencional con una eficiencia de 78,00 %, en la concentración del 2 % de sólidos utilizando coagulante.Sociedad Química del Perú2020-02-18info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontexttextoapplication/pdfhttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/19410.37761/rsqp.v84i3.194Revista de la Sociedad Química del Perú; Vol. 84 Núm. 3 (2018): Revista de la Sociedad Química del Perú; 336 - 349Journal of the Chemical Society of Peru; Vol. 84 No. 3 (2018): Jounal of Sociedad Química del Perú; 336 - 3492309-87401810-634X10.37761/rsqp.v84i3reponame:Revista de la Sociedad Química del Perúinstname:Sociedad Química del Perúinstacron:SQPspahttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/194/16620182018Derechos de autor 2018 Sociedad Química del Perúhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:rsqp.revistas.sqperu.org.pe:article/1942020-03-03T19:38:13Z |
| dc.title.none.fl_str_mv |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS EFICIENCIA DE UN SEDIMENTADOR LAMINAR Y CONVENCIONAL PARA ELIMINAR SÓLIDOS |
| title |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS |
| spellingShingle |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS Guerrero Vejarano, Tania E. sedimentation efficiency sedimentable solids flocculation laminar sedimentation conventional sedimentation sedimentación eficiencia sólidos sedimentables floculación sedimentador laminar sedimentador convencional |
| title_short |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS |
| title_full |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS |
| title_fullStr |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS |
| title_full_unstemmed |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS |
| title_sort |
EFFICIENCY OF A LAMINAR SEDIMENTER AND CONVENTIONAL TO ELIMINATE SOLIDS |
| dc.creator.none.fl_str_mv |
Guerrero Vejarano, Tania E. Salazar Álvarez, Juan C. Paredes Salazar, José L. |
| author |
Guerrero Vejarano, Tania E. |
| author_facet |
Guerrero Vejarano, Tania E. Salazar Álvarez, Juan C. Paredes Salazar, José L. |
| author_role |
author |
| author2 |
Salazar Álvarez, Juan C. Paredes Salazar, José L. |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
sedimentation efficiency sedimentable solids flocculation laminar sedimentation conventional sedimentation sedimentación eficiencia sólidos sedimentables floculación sedimentador laminar sedimentador convencional |
| topic |
sedimentation efficiency sedimentable solids flocculation laminar sedimentation conventional sedimentation sedimentación eficiencia sólidos sedimentables floculación sedimentador laminar sedimentador convencional |
| description |
The objective of this research was to determine the efficiency of the laminar and conventional sedimentation system to eliminate different concentrations of suspended solids, for which different physicochemical parameters were taken into account (temperature, pH, turbidity, dissolved oxygen and dry residue). To determine the physicochemical parameters, water samples were prepared at different concentrations (1, 2 and 3%) of solids, which were analyzed at the inlet and outlet of the settler, in treatments with coagulant and without coagulant, with three repetitions at each treatment. To determine which of the sedimentation was more efficient, analysis of variance and Tukey test of the evaluated factors (type of settler, coagulant and concentration of solids) were performed, obtaining as a result significant differences between both settlings with |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020-02-18 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion text texto |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/194 10.37761/rsqp.v84i3.194 |
| url |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/194 |
| identifier_str_mv |
10.37761/rsqp.v84i3.194 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/194/166 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2018 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2018 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.coverage.none.fl_str_mv |
2018 2018 |
| dc.publisher.none.fl_str_mv |
Sociedad Química del Perú |
| publisher.none.fl_str_mv |
Sociedad Química del Perú |
| dc.source.none.fl_str_mv |
Revista de la Sociedad Química del Perú; Vol. 84 Núm. 3 (2018): Revista de la Sociedad Química del Perú; 336 - 349 Journal of the Chemical Society of Peru; Vol. 84 No. 3 (2018): Jounal of Sociedad Química del Perú; 336 - 349 2309-8740 1810-634X 10.37761/rsqp.v84i3 reponame:Revista de la Sociedad Química del Perú instname:Sociedad Química del Perú instacron:SQP |
| instname_str |
Sociedad Química del Perú |
| instacron_str |
SQP |
| institution |
SQP |
| reponame_str |
Revista de la Sociedad Química del Perú |
| collection |
Revista de la Sociedad Química del Perú |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1847240722204327936 |
| score |
12.884794 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).