BPS ultrasound (PBE) in fetal surveillance.
Descripción del Articulo
Results of a longitudinal prospective study done between 1988 and 1993 to determine the predictive value in fetal wellbeing of the ultrasound biophysical profile (UBP) created by the first author a represented. The UBP considers seven feto-placental parameters: fetal movements, respiratory movement...
| Autores: | , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2015 |
| Institución: | Sociedad Peruana de Obstetricia y Ginecología |
| Repositorio: | Revista Peruana de Ginecología y Obstetricia |
| Lenguaje: | español |
| OAI Identifier: | oai:ginecologiayobstetricia.pe:article/1706 |
| Enlace del recurso: | https://ginecologiayobstetricia.pe/index.php/RPGO/article/view/1706 |
| Nivel de acceso: | acceso abierto |
| id |
REVSPOG_6207114b4a34975c4f07c55b4e8b17f4 |
|---|---|
| oai_identifier_str |
oai:ginecologiayobstetricia.pe:article/1706 |
| network_acronym_str |
REVSPOG |
| network_name_str |
Revista Peruana de Ginecología y Obstetricia |
| repository_id_str |
. |
| spelling |
BPS ultrasound (PBE) in fetal surveillance.Perfil biofísico ecográfico (PBE) en vigilancia fetal.Huamán, MoisésPacheco, JoséRosales, HugoArias, LilianResults of a longitudinal prospective study done between 1988 and 1993 to determine the predictive value in fetal wellbeing of the ultrasound biophysical profile (UBP) created by the first author a represented. The UBP considers seven feto-placental parameters: fetal movements, respiratory movements, fetal tone, basal heart frequency, cardiac reactivity, amniotic fluid volume and placental maturity. We assigned two points to each normal parameter. We performed 1434 studies in high risk pregnancies over 27 week; with presumptive diagnosis of prolonged pregnancy, pregnancy induced hypertension, fetal distress, intrauterine fetal growth retardation, premature rupture of membranes and others. We considered normal air UBP score of 11 to 14, and correlated score; with one or more of the following adverse perinatal results: clinical oligohydramnios, thick meconial amniotic fluid, Apgar less than 8 at 5 minutes, neonatal convulsions perinatal death. UBP value were: sensitivity 82,6%, specificity 98,8%, positive predictive value 88,8%, negative predictive value 98,1% false positive index 11,2% false negative index 1,9%; prevalence 10%. Cesarean-section rate in the study group was lass than expected and the perinatal mortality 0,69 x 1000 l.b. was much less than The global hospital rate. UBP appear as an important tool in fetal surveillance.Se informa los resultados de un estudio longitudinal prospectivo realizado entre 1988y 1993, con el objetivo de determinar el valor predictivo, en el estado de la salud fetal, del perfil biofísico ecográfico (PBE) ideado por el primer autor, el cual utiliza siete parámetros fetoplacentarios evaluados por ultra-sonografía: movimientos corporales, movimientos respiratorios, tono fetal, frecuencia cardiaca basal, reactividad cardiaca, volumen de líquido amniótico y madurez placentaria. A cada parámetro normal se le asignó dos puntos. Se efectuó l434 estudios en gestantes de riesgo alto con más de 27 semanas de gestación que tenían presunción diagnóstica de: embarazo prolongado, hipertensión inducida por el embarazo, sufrimiento fetal, retardo de crecimiento intratuterino, rotura prematura de membranas y otros. Se consideró como PBE normal un puntaje de 11 a 14, relacionándose los puntajes a uno o más de los siguientes resultados perinatales adversos: oligohidramnios clínico, líquido meconial espeso, Apgar menor de 8 a los 5 minutos, convulsiones neonatales, muerte perinatal. Los valores del PBE fueron: sensibilidad 82,6%, especificidad 98,8%, valor predictivo positivo 88,801ó, valor predictivo, negativo 98,1%, índice de falsos positivos 11,2%, índice de falsos negativos 1,9%, la prevalencia fue 10%. La tasa de cesáreas en el grupo de estudio fue menor a la global hospitalaria y la mortalidad perinatal 0, ó9 x 1000 n. v., mucho menor a la global. Estos resultados ubican al PBE entre las pruebas de mayor valor en vigilancia fetal.Sociedad Peruana de Obstetricia y Ginecología2015-07-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ginecologiayobstetricia.pe/index.php/RPGO/article/view/170610.31403/rpgo.v41i1706The Peruvian Journal of Gynecology and Obstetrics ; Vol. 41 No. 1 (1995); 52-55Revista Peruana de Ginecología y Obstetricia; Vol. 41 Núm. 1 (1995); 52-552304-51322304-5124reponame:Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttps://ginecologiayobstetricia.pe/index.php/RPGO/article/view/1706/pdf_205info:eu-repo/semantics/openAccessoai:ginecologiayobstetricia.pe:article/17062026-01-12T19:11:00Z |
| dc.title.none.fl_str_mv |
BPS ultrasound (PBE) in fetal surveillance. Perfil biofísico ecográfico (PBE) en vigilancia fetal. |
| title |
BPS ultrasound (PBE) in fetal surveillance. |
| spellingShingle |
BPS ultrasound (PBE) in fetal surveillance. Huamán, Moisés |
| title_short |
BPS ultrasound (PBE) in fetal surveillance. |
| title_full |
BPS ultrasound (PBE) in fetal surveillance. |
| title_fullStr |
BPS ultrasound (PBE) in fetal surveillance. |
| title_full_unstemmed |
BPS ultrasound (PBE) in fetal surveillance. |
| title_sort |
BPS ultrasound (PBE) in fetal surveillance. |
| dc.creator.none.fl_str_mv |
Huamán, Moisés Pacheco, José Rosales, Hugo Arias, Lilian |
| author |
Huamán, Moisés |
| author_facet |
Huamán, Moisés Pacheco, José Rosales, Hugo Arias, Lilian |
| author_role |
author |
| author2 |
Pacheco, José Rosales, Hugo Arias, Lilian |
| author2_role |
author author author |
| description |
Results of a longitudinal prospective study done between 1988 and 1993 to determine the predictive value in fetal wellbeing of the ultrasound biophysical profile (UBP) created by the first author a represented. The UBP considers seven feto-placental parameters: fetal movements, respiratory movements, fetal tone, basal heart frequency, cardiac reactivity, amniotic fluid volume and placental maturity. We assigned two points to each normal parameter. We performed 1434 studies in high risk pregnancies over 27 week; with presumptive diagnosis of prolonged pregnancy, pregnancy induced hypertension, fetal distress, intrauterine fetal growth retardation, premature rupture of membranes and others. We considered normal air UBP score of 11 to 14, and correlated score; with one or more of the following adverse perinatal results: clinical oligohydramnios, thick meconial amniotic fluid, Apgar less than 8 at 5 minutes, neonatal convulsions perinatal death. UBP value were: sensitivity 82,6%, specificity 98,8%, positive predictive value 88,8%, negative predictive value 98,1% false positive index 11,2% false negative index 1,9%; prevalence 10%. Cesarean-section rate in the study group was lass than expected and the perinatal mortality 0,69 x 1000 l.b. was much less than The global hospital rate. UBP appear as an important tool in fetal surveillance. |
| publishDate |
2015 |
| dc.date.none.fl_str_mv |
2015-07-31 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://ginecologiayobstetricia.pe/index.php/RPGO/article/view/1706 10.31403/rpgo.v41i1706 |
| url |
https://ginecologiayobstetricia.pe/index.php/RPGO/article/view/1706 |
| identifier_str_mv |
10.31403/rpgo.v41i1706 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://ginecologiayobstetricia.pe/index.php/RPGO/article/view/1706/pdf_205 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Sociedad Peruana de Obstetricia y Ginecología |
| publisher.none.fl_str_mv |
Sociedad Peruana de Obstetricia y Ginecología |
| dc.source.none.fl_str_mv |
The Peruvian Journal of Gynecology and Obstetrics ; Vol. 41 No. 1 (1995); 52-55 Revista Peruana de Ginecología y Obstetricia; Vol. 41 Núm. 1 (1995); 52-55 2304-5132 2304-5124 reponame:Revista Peruana de Ginecología y Obstetricia instname:Sociedad Peruana de Obstetricia y Ginecología instacron:SPOG |
| instname_str |
Sociedad Peruana de Obstetricia y Ginecología |
| instacron_str |
SPOG |
| institution |
SPOG |
| reponame_str |
Revista Peruana de Ginecología y Obstetricia |
| collection |
Revista Peruana de Ginecología y Obstetricia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1868078731320360960 |
| score |
13.408945 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).