Oxygen saturation in patients during hemodialysis at different altitudes

Descripción del Articulo

Introduction Patients undergoing hemodialysis may develop hypoxemia during the procedure, and hypoxemia may become more intense if hemodialysis is performed in a high altitude environment. Objectives To assess variations in oxygen saturation in patients undergoing hemodialysis at different altitude...

Descripción completa

Detalles Bibliográficos
Autores: Rosales-Mendoza, Karina, Gonzalez-Polar, Jose, Sumen , Romina, Vizcarra Vizcarra, Christian, Hurtado-Aréstegui, Abdias
Formato: artículo
Fecha de Publicación:2021
Institución:Colegio Médico del Perú
Repositorio:Acta Médica Peruana
Lenguaje:español
OAI Identifier:oai:amp.cmp.org.pe:article/2146
Enlace del recurso:https://amp.cmp.org.pe/index.php/AMP/article/view/2146
Nivel de acceso:acceso abierto
Materia:Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
id REVCMP_7cc8fcdd95a7a2baa8a193404fbdedde
oai_identifier_str oai:amp.cmp.org.pe:article/2146
network_acronym_str REVCMP
network_name_str Acta Médica Peruana
repository_id_str .
spelling Oxygen saturation in patients during hemodialysis at different altitudesSaturación de oxígeno en pacientes durante hemodiálisis a diferentes altitudesRosales-Mendoza, KarinaGonzalez-Polar, JoseSumen , RominaVizcarra Vizcarra, ChristianHurtado-Aréstegui, AbdiasRosales-Mendoza, KarinaGonzalez-Polar, JoseSumen , RominaVizcarra Vizcarra, ChristianHurtado-Aréstegui, AbdiasOximetría cutáneahemodiálisisaltitudCutaneous oximetryhemodialysisAltitudeIntroduction Patients undergoing hemodialysis may develop hypoxemia during the procedure, and hypoxemia may become more intense if hemodialysis is performed in a high altitude environment. Objectives To assess variations in oxygen saturation in patients undergoing hemodialysis at different altitude levels. Material and methods This is a prospective case series, where patients from hemodialysis programs in three cities were assessed. These places were at 101-, 2335-, and 3825- meters above sea level. Patients had their oxygen saturation measured in a semi-sitting position with a pulse oxymeter device. Measurements were taken before, during, and at the end of hemodialysis sessions. Results Sixty-five patients undergoing hemodialysis were included. They were from three cities at different altitude above sea level. Oxygen saturation significantly decreased as long as altitude increased (97,32 ± 1,10 vs. 94,75 ± 2,17 vs. 84,85 ± 5,86 p= 0,00). Oxygen saturation showed changes before, during, and at the end of hemodialysis procedures at different altitude. Ferritin levels were lower in high altitude patients compared with those at sea level and at moderate altitude (131,75 [106,04 – 157,45] vs. 493,38 [273,19 – 713,56] vs. 550,66 [329,75-771,57] p=0,01). Hemoglobin values were lower in patients from middle altitude levels (10,8 [10,12-11,47] vs 11,32 [10,79-11,85] vs 11,84 [11,54-12,14] p=0,03) Conclusions In patients undergoing chronic hemodialysis oxygen saturation is reduced as long as altitude increases, and significant variations were found during hemodialysis procedures.Introducción Los pacientes en hemodiálisis pueden presentar hipoxemia durante este procedimiento, la cual puede ser mayor si la hemodiálisis se realiza en ciudades de mayor altitud. Objetivos Evaluar las modificaciones de la saturación de oxígeno en pacientes con enfermedad renal crónica en estadio 5 en hemodiálisis a diferentes altitudes. Material y métodos Estudio descriptivo, prospectivo observacional, de pacientes con enfermedad renal crónica estadío 5 en programa de hemodiálisis, en tres ciudades localizadas a diferente altitud: 101, 2335 y 3,825 metros sobre el nivel del mar, en los que se evaluó la saturación de oxígeno en posición semisentada con pulsoxímetro: antes, durante y al finalizar el procedimiento de hemodiálisis. Resultados Se incluyeron 65 pacientes en hemodiálisis, de 3 ciudades de diferente altitud, con características similares, la saturación de oxígeno disminuyó significativamente a medida que aumentaba la altitud (97,3 ± 1,1 vs 94,8 ± 2,1 vs 84,8 ± 5,9 p=0,001), la saturación de oxígeno no mostró cambios antes, ni durante la hemodiálisis en las diferentes altitudes. Los niveles de ferritina fueron menores en pacientes de gran altitud comparado con los de nivel del mar (132 ± 57 vs 493 ± 492 p=0,001).  Conclusiones En pacientes en hemodiálisis la saturación de oxígeno disminuye a medida que incrementa la altitud y no se encontró disminución significativa durante la hemodiálisis.Colegio Médico del Perú2021-10-24info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://amp.cmp.org.pe/index.php/AMP/article/view/214610.35663/amp.2021.383.2146ACTA MEDICA PERUANA; Vol. 38 No. 3 (2021): July - SeptemberACTA MEDICA PERUANA; Vol. 38 Núm. 3 (2021): Julio - Setiembre1728-59171018-8800reponame:Acta Médica Peruanainstname:Colegio Médico del Perúinstacron:CMPspahttps://amp.cmp.org.pe/index.php/AMP/article/view/2146/1410Copyright (c) 2021 ACTA MEDICA PERUANAinfo:eu-repo/semantics/openAccessoai:amp.cmp.org.pe:article/21462023-10-12T07:47:27Z
dc.title.none.fl_str_mv Oxygen saturation in patients during hemodialysis at different altitudes
Saturación de oxígeno en pacientes durante hemodiálisis a diferentes altitudes
title Oxygen saturation in patients during hemodialysis at different altitudes
spellingShingle Oxygen saturation in patients during hemodialysis at different altitudes
Rosales-Mendoza, Karina
Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
title_short Oxygen saturation in patients during hemodialysis at different altitudes
title_full Oxygen saturation in patients during hemodialysis at different altitudes
title_fullStr Oxygen saturation in patients during hemodialysis at different altitudes
title_full_unstemmed Oxygen saturation in patients during hemodialysis at different altitudes
title_sort Oxygen saturation in patients during hemodialysis at different altitudes
dc.creator.none.fl_str_mv Rosales-Mendoza, Karina
Gonzalez-Polar, Jose
Sumen , Romina
Vizcarra Vizcarra, Christian
Hurtado-Aréstegui, Abdias
Rosales-Mendoza, Karina
Gonzalez-Polar, Jose
Sumen , Romina
Vizcarra Vizcarra, Christian
Hurtado-Aréstegui, Abdias
author Rosales-Mendoza, Karina
author_facet Rosales-Mendoza, Karina
Gonzalez-Polar, Jose
Sumen , Romina
Vizcarra Vizcarra, Christian
Hurtado-Aréstegui, Abdias
Gonzalez-Polar, Jose
author_role author
author2 Gonzalez-Polar, Jose
Sumen , Romina
Vizcarra Vizcarra, Christian
Hurtado-Aréstegui, Abdias
Gonzalez-Polar, Jose
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
topic Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
description Introduction Patients undergoing hemodialysis may develop hypoxemia during the procedure, and hypoxemia may become more intense if hemodialysis is performed in a high altitude environment. Objectives To assess variations in oxygen saturation in patients undergoing hemodialysis at different altitude levels. Material and methods This is a prospective case series, where patients from hemodialysis programs in three cities were assessed. These places were at 101-, 2335-, and 3825- meters above sea level. Patients had their oxygen saturation measured in a semi-sitting position with a pulse oxymeter device. Measurements were taken before, during, and at the end of hemodialysis sessions. Results Sixty-five patients undergoing hemodialysis were included. They were from three cities at different altitude above sea level. Oxygen saturation significantly decreased as long as altitude increased (97,32 ± 1,10 vs. 94,75 ± 2,17 vs. 84,85 ± 5,86 p= 0,00). Oxygen saturation showed changes before, during, and at the end of hemodialysis procedures at different altitude. Ferritin levels were lower in high altitude patients compared with those at sea level and at moderate altitude (131,75 [106,04 – 157,45] vs. 493,38 [273,19 – 713,56] vs. 550,66 [329,75-771,57] p=0,01). Hemoglobin values were lower in patients from middle altitude levels (10,8 [10,12-11,47] vs 11,32 [10,79-11,85] vs 11,84 [11,54-12,14] p=0,03) Conclusions In patients undergoing chronic hemodialysis oxygen saturation is reduced as long as altitude increases, and significant variations were found during hemodialysis procedures.
publishDate 2021
dc.date.none.fl_str_mv 2021-10-24
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://amp.cmp.org.pe/index.php/AMP/article/view/2146
10.35663/amp.2021.383.2146
url https://amp.cmp.org.pe/index.php/AMP/article/view/2146
identifier_str_mv 10.35663/amp.2021.383.2146
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://amp.cmp.org.pe/index.php/AMP/article/view/2146/1410
dc.rights.none.fl_str_mv Copyright (c) 2021 ACTA MEDICA PERUANA
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 ACTA MEDICA PERUANA
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Colegio Médico del Perú
publisher.none.fl_str_mv Colegio Médico del Perú
dc.source.none.fl_str_mv ACTA MEDICA PERUANA; Vol. 38 No. 3 (2021): July - September
ACTA MEDICA PERUANA; Vol. 38 Núm. 3 (2021): Julio - Setiembre
1728-5917
1018-8800
reponame:Acta Médica Peruana
instname:Colegio Médico del Perú
instacron:CMP
instname_str Colegio Médico del Perú
instacron_str CMP
institution CMP
reponame_str Acta Médica Peruana
collection Acta Médica Peruana
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1846515733230518272
score 13.425424
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).