A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water

Descripción del Articulo

Anodic-stripping voltammetry, like as other electro-analytical techniques of chemical analysis can be very valuable as complements for neutron activation analysis (NAA), for rapid, accurate and simultaneous determination of some trace elements in water and in digested biological samples at the ppb(...

Descripción completa

Detalles Bibliográficos
Autores: Montoya, Eduardo, Baltuano, Oscar, Mendoza, Mario, Hernández, Yuri, Montoya, H.
Formato: artículo
Fecha de Publicación:2002
Institución:Instituto Peruano de Energía Nuclear
Repositorio:IPEN-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.ipen.gob.pe:20.500.13054/192
Enlace del recurso:https://hdl.handle.net/20.500.13054/192
Nivel de acceso:acceso abierto
Materia:Análisis químico
Voltametría
Análisis por activación neutrónica
Microelementos
id IPEN_ab93e66ab841ac5a857c4ebe89d2d483
oai_identifier_str oai:repositorio.ipen.gob.pe:20.500.13054/192
network_acronym_str IPEN
network_name_str IPEN-Institucional
repository_id_str 3248
spelling Montoya, EduardoBaltuano, OscarMendoza, MarioHernández, YuriMontoya, H.Baltuano, OscarMontoya, H.Hernández, YuriMontoya, EduardoMendoza, Mario2014-08-12T17:17:42Z2014-08-12T17:17:42Z2002-06Montoya E, et al. A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water. Instituto Peruano de Energía Nuclear. Informe Científico Tecnológico 1998-2001. Lima: IPEN; 2002. p. 105-107.1684-1662https://hdl.handle.net/20.500.13054/192Anodic-stripping voltammetry, like as other electro-analytical techniques of chemical analysis can be very valuable as complements for neutron activation analysis (NAA), for rapid, accurate and simultaneous determination of some trace elements in water and in digested biological samples at the ppb(g/L) range. Commercial voltammetric analyzers may have a cost in the range of US$ 20,000.00 and the limited budget of our NAA laboratory not allow us to buy this kind of complementary instrumentation. In this paper we describe a PC- based voltammetric analyzer, designed and built in our laboratories at a relatively low cost.Instituto Peruano de Energía Nuclearapplication/pdfengLimaPEinfo:eu-repo/semantics/openAccessInstituto Peruano de Energía NuclearRepositorio Institucional del Instituto Peruano de Energía Nuclearreponame:IPEN-Institucionalinstname:Instituto Peruano de Energía Nuclearinstacron:IPENAnálisis químicoVoltametríaAnálisis por activación neutrónicaMicroelementosA low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in waterinfo:eu-repo/semantics/articleORIGINALPag. 105-107- ICT 1998-2001.pdfPag. 105-107- ICT 1998-2001.pdfapplication/pdf58097https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/1/Pag.%20105-107-%20ICT%201998-2001.pdf14876fe6101a2b7dea01cee3f7312c18MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-8103https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/2/license.txt7ecf7b0639239de61a3a1ede9c397fecMD52TEXTPag. 105-107- ICT 1998-2001.pdf.txtPag. 105-107- ICT 1998-2001.pdf.txtExtracted texttext/plain5946https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/3/Pag.%20105-107-%20ICT%201998-2001.pdf.txtbf17537ad6230776e0a19beec2ba176bMD53THUMBNAILPag. 105-107- ICT 1998-2001.pdf.jpgPag. 105-107- ICT 1998-2001.pdf.jpgGenerated Thumbnailimage/jpeg19887https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/4/Pag.%20105-107-%20ICT%201998-2001.pdf.jpgb1c7d9a424a0065ab508c9fa529ee76eMD5420.500.13054/192oai:repositorio.ipen.gob.pe:20.500.13054/1922022-02-07 18:05:21.368Repositorio Institucional del Instituto Peruano de Energía Nuclearrepositorio@ipen.gob.peU2UgRGlzdHJpYnV5ZSBiYWpvIHVuYSBMaWNlbmNpYSBDcmVhdGl2ZSBDb21tb25zIEF0cmlidWNpw7NuLU5vQ29tZXJjaWFsLVNpbkRlcml2YXIgNC4wIEludGVybmFjaW9uYWwuCg==
dc.title.es_PE.fl_str_mv A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
title A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
spellingShingle A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
Montoya, Eduardo
Análisis químico
Voltametría
Análisis por activación neutrónica
Microelementos
title_short A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
title_full A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
title_fullStr A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
title_full_unstemmed A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
title_sort A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
dc.creator.none.fl_str_mv Baltuano, Oscar
Montoya, H.
Hernández, Yuri
Montoya, Eduardo
Mendoza, Mario
author Montoya, Eduardo
author_facet Montoya, Eduardo
Baltuano, Oscar
Mendoza, Mario
Hernández, Yuri
Montoya, H.
author_role author
author2 Baltuano, Oscar
Mendoza, Mario
Hernández, Yuri
Montoya, H.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Montoya, Eduardo
Baltuano, Oscar
Mendoza, Mario
Hernández, Yuri
Montoya, H.
dc.subject.es_PE.fl_str_mv Análisis químico
Voltametría
Análisis por activación neutrónica
Microelementos
topic Análisis químico
Voltametría
Análisis por activación neutrónica
Microelementos
description Anodic-stripping voltammetry, like as other electro-analytical techniques of chemical analysis can be very valuable as complements for neutron activation analysis (NAA), for rapid, accurate and simultaneous determination of some trace elements in water and in digested biological samples at the ppb(g/L) range. Commercial voltammetric analyzers may have a cost in the range of US$ 20,000.00 and the limited budget of our NAA laboratory not allow us to buy this kind of complementary instrumentation. In this paper we describe a PC- based voltammetric analyzer, designed and built in our laboratories at a relatively low cost.
publishDate 2002
dc.date.accessioned.none.fl_str_mv 2014-08-12T17:17:42Z
dc.date.available.none.fl_str_mv 2014-08-12T17:17:42Z
dc.date.issued.fl_str_mv 2002-06
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.citation.es_PE.fl_str_mv Montoya E, et al. A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water. Instituto Peruano de Energía Nuclear. Informe Científico Tecnológico 1998-2001. Lima: IPEN; 2002. p. 105-107.
dc.identifier.issn.none.fl_str_mv 1684-1662
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.13054/192
identifier_str_mv Montoya E, et al. A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water. Instituto Peruano de Energía Nuclear. Informe Científico Tecnológico 1998-2001. Lima: IPEN; 2002. p. 105-107.
1684-1662
url https://hdl.handle.net/20.500.13054/192
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Lima
dc.publisher.country.es_PE.fl_str_mv PE
dc.source.es_PE.fl_str_mv Instituto Peruano de Energía Nuclear
Repositorio Institucional del Instituto Peruano de Energía Nuclear
dc.source.none.fl_str_mv reponame:IPEN-Institucional
instname:Instituto Peruano de Energía Nuclear
instacron:IPEN
instname_str Instituto Peruano de Energía Nuclear
instacron_str IPEN
institution IPEN
reponame_str IPEN-Institucional
collection IPEN-Institucional
bitstream.url.fl_str_mv https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/1/Pag.%20105-107-%20ICT%201998-2001.pdf
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/2/license.txt
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/3/Pag.%20105-107-%20ICT%201998-2001.pdf.txt
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/4/Pag.%20105-107-%20ICT%201998-2001.pdf.jpg
bitstream.checksum.fl_str_mv 14876fe6101a2b7dea01cee3f7312c18
7ecf7b0639239de61a3a1ede9c397fec
bf17537ad6230776e0a19beec2ba176b
b1c7d9a424a0065ab508c9fa529ee76e
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional del Instituto Peruano de Energía Nuclear
repository.mail.fl_str_mv repositorio@ipen.gob.pe
_version_ 1846785879571431424
score 13.057984
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).