A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water
Descripción del Articulo
Anodic-stripping voltammetry, like as other electro-analytical techniques of chemical analysis can be very valuable as complements for neutron activation analysis (NAA), for rapid, accurate and simultaneous determination of some trace elements in water and in digested biological samples at the ppb(...
| Autores: | , , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2002 |
| Institución: | Instituto Peruano de Energía Nuclear |
| Repositorio: | IPEN-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.ipen.gob.pe:20.500.13054/192 |
| Enlace del recurso: | https://hdl.handle.net/20.500.13054/192 |
| Nivel de acceso: | acceso abierto |
| Materia: | Análisis químico Voltametría Análisis por activación neutrónica Microelementos |
| id |
IPEN_ab93e66ab841ac5a857c4ebe89d2d483 |
|---|---|
| oai_identifier_str |
oai:repositorio.ipen.gob.pe:20.500.13054/192 |
| network_acronym_str |
IPEN |
| network_name_str |
IPEN-Institucional |
| repository_id_str |
3248 |
| spelling |
Montoya, EduardoBaltuano, OscarMendoza, MarioHernández, YuriMontoya, H.Baltuano, OscarMontoya, H.Hernández, YuriMontoya, EduardoMendoza, Mario2014-08-12T17:17:42Z2014-08-12T17:17:42Z2002-06Montoya E, et al. A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water. Instituto Peruano de Energía Nuclear. Informe Científico Tecnológico 1998-2001. Lima: IPEN; 2002. p. 105-107.1684-1662https://hdl.handle.net/20.500.13054/192Anodic-stripping voltammetry, like as other electro-analytical techniques of chemical analysis can be very valuable as complements for neutron activation analysis (NAA), for rapid, accurate and simultaneous determination of some trace elements in water and in digested biological samples at the ppb(g/L) range. Commercial voltammetric analyzers may have a cost in the range of US$ 20,000.00 and the limited budget of our NAA laboratory not allow us to buy this kind of complementary instrumentation. In this paper we describe a PC- based voltammetric analyzer, designed and built in our laboratories at a relatively low cost.Instituto Peruano de Energía Nuclearapplication/pdfengLimaPEinfo:eu-repo/semantics/openAccessInstituto Peruano de Energía NuclearRepositorio Institucional del Instituto Peruano de Energía Nuclearreponame:IPEN-Institucionalinstname:Instituto Peruano de Energía Nuclearinstacron:IPENAnálisis químicoVoltametríaAnálisis por activación neutrónicaMicroelementosA low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in waterinfo:eu-repo/semantics/articleORIGINALPag. 105-107- ICT 1998-2001.pdfPag. 105-107- ICT 1998-2001.pdfapplication/pdf58097https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/1/Pag.%20105-107-%20ICT%201998-2001.pdf14876fe6101a2b7dea01cee3f7312c18MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-8103https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/2/license.txt7ecf7b0639239de61a3a1ede9c397fecMD52TEXTPag. 105-107- ICT 1998-2001.pdf.txtPag. 105-107- ICT 1998-2001.pdf.txtExtracted texttext/plain5946https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/3/Pag.%20105-107-%20ICT%201998-2001.pdf.txtbf17537ad6230776e0a19beec2ba176bMD53THUMBNAILPag. 105-107- ICT 1998-2001.pdf.jpgPag. 105-107- ICT 1998-2001.pdf.jpgGenerated Thumbnailimage/jpeg19887https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/4/Pag.%20105-107-%20ICT%201998-2001.pdf.jpgb1c7d9a424a0065ab508c9fa529ee76eMD5420.500.13054/192oai:repositorio.ipen.gob.pe:20.500.13054/1922022-02-07 18:05:21.368Repositorio Institucional del Instituto Peruano de Energía Nuclearrepositorio@ipen.gob.peU2UgRGlzdHJpYnV5ZSBiYWpvIHVuYSBMaWNlbmNpYSBDcmVhdGl2ZSBDb21tb25zIEF0cmlidWNpw7NuLU5vQ29tZXJjaWFsLVNpbkRlcml2YXIgNC4wIEludGVybmFjaW9uYWwuCg== |
| dc.title.es_PE.fl_str_mv |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| title |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| spellingShingle |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water Montoya, Eduardo Análisis químico Voltametría Análisis por activación neutrónica Microelementos |
| title_short |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| title_full |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| title_fullStr |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| title_full_unstemmed |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| title_sort |
A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water |
| dc.creator.none.fl_str_mv |
Baltuano, Oscar Montoya, H. Hernández, Yuri Montoya, Eduardo Mendoza, Mario |
| author |
Montoya, Eduardo |
| author_facet |
Montoya, Eduardo Baltuano, Oscar Mendoza, Mario Hernández, Yuri Montoya, H. |
| author_role |
author |
| author2 |
Baltuano, Oscar Mendoza, Mario Hernández, Yuri Montoya, H. |
| author2_role |
author author author author |
| dc.contributor.author.fl_str_mv |
Montoya, Eduardo Baltuano, Oscar Mendoza, Mario Hernández, Yuri Montoya, H. |
| dc.subject.es_PE.fl_str_mv |
Análisis químico Voltametría Análisis por activación neutrónica Microelementos |
| topic |
Análisis químico Voltametría Análisis por activación neutrónica Microelementos |
| description |
Anodic-stripping voltammetry, like as other electro-analytical techniques of chemical analysis can be very valuable as complements for neutron activation analysis (NAA), for rapid, accurate and simultaneous determination of some trace elements in water and in digested biological samples at the ppb(g/L) range. Commercial voltammetric analyzers may have a cost in the range of US$ 20,000.00 and the limited budget of our NAA laboratory not allow us to buy this kind of complementary instrumentation. In this paper we describe a PC- based voltammetric analyzer, designed and built in our laboratories at a relatively low cost. |
| publishDate |
2002 |
| dc.date.accessioned.none.fl_str_mv |
2014-08-12T17:17:42Z |
| dc.date.available.none.fl_str_mv |
2014-08-12T17:17:42Z |
| dc.date.issued.fl_str_mv |
2002-06 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.citation.es_PE.fl_str_mv |
Montoya E, et al. A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water. Instituto Peruano de Energía Nuclear. Informe Científico Tecnológico 1998-2001. Lima: IPEN; 2002. p. 105-107. |
| dc.identifier.issn.none.fl_str_mv |
1684-1662 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.13054/192 |
| identifier_str_mv |
Montoya E, et al. A low cost pc-based voltammetric analyzer for determination of cadmium, copper, lead, nickel, zinc and other trace elements in water. Instituto Peruano de Energía Nuclear. Informe Científico Tecnológico 1998-2001. Lima: IPEN; 2002. p. 105-107. 1684-1662 |
| url |
https://hdl.handle.net/20.500.13054/192 |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.es_PE.fl_str_mv |
application/pdf |
| dc.publisher.es_PE.fl_str_mv |
Lima |
| dc.publisher.country.es_PE.fl_str_mv |
PE |
| dc.source.es_PE.fl_str_mv |
Instituto Peruano de Energía Nuclear Repositorio Institucional del Instituto Peruano de Energía Nuclear |
| dc.source.none.fl_str_mv |
reponame:IPEN-Institucional instname:Instituto Peruano de Energía Nuclear instacron:IPEN |
| instname_str |
Instituto Peruano de Energía Nuclear |
| instacron_str |
IPEN |
| institution |
IPEN |
| reponame_str |
IPEN-Institucional |
| collection |
IPEN-Institucional |
| bitstream.url.fl_str_mv |
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/1/Pag.%20105-107-%20ICT%201998-2001.pdf https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/2/license.txt https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/3/Pag.%20105-107-%20ICT%201998-2001.pdf.txt https://repositorio.ipen.gob.pe/bitstream/20.500.13054/192/4/Pag.%20105-107-%20ICT%201998-2001.pdf.jpg |
| bitstream.checksum.fl_str_mv |
14876fe6101a2b7dea01cee3f7312c18 7ecf7b0639239de61a3a1ede9c397fec bf17537ad6230776e0a19beec2ba176b b1c7d9a424a0065ab508c9fa529ee76e |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Institucional del Instituto Peruano de Energía Nuclear |
| repository.mail.fl_str_mv |
repositorio@ipen.gob.pe |
| _version_ |
1846785879571431424 |
| score |
13.057984 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).