Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco
Descripción del Articulo
A specially designed electromagnetic transmission line is used as an in-line real-time transducer of alcohol content in pisco beverage production. During the distillation process, as the beverage is collected in a tank, it is homogenized, and a sample is continuously pumped into the coaxial line tra...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2016 |
| Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
| Repositorio: | CONCYTEC-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/968 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12390/968 https://doi.org/10.1109/JSEN.2016.2594955 |
| Nivel de acceso: | acceso abierto |
| Materia: | Bebida alcohólica https://purl.org/pe-repo/ocde/ford#2.11.01 |
| id |
CONC_1a3c1906cca7706d7c910cffdd9ed1ff |
|---|---|
| oai_identifier_str |
oai:repositorio.concytec.gob.pe:20.500.12390/968 |
| network_acronym_str |
CONC |
| network_name_str |
CONCYTEC-Institucional |
| repository_id_str |
4689 |
| spelling |
Publicationrp02648600rp02647600Santos, EJPCalderon, CHJ2024-05-30T23:13:38Z2024-05-30T23:13:38Z2016https://hdl.handle.net/20.500.12390/968https://doi.org/10.1109/JSEN.2016.2594955447105600008A specially designed electromagnetic transmission line is used as an in-line real-time transducer of alcohol content in pisco beverage production. During the distillation process, as the beverage is collected in a tank, it is homogenized, and a sample is continuously pumped into the coaxial line transducer. Pisco is a beverage with 53%-62% water, and 47%-38% alcohol, with 90% of the alcohol content being ethanol. The alcohol content of the flow is detected by measuring the electromagnetic attenuation of the TEM mode propagating inside the transmission line. The propagating mode frequency is selected in the 1-1.5 GHz range, enabling the measurement of alcohol concentration from 0% up to 100%, displaying an almost linear relationship between the alcohol concentration and power absorption in decibels.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengIEEE Sensors JournalIEEE Sensors Journalinfo:eu-repo/semantics/openAccessBebida alcohólicahttps://purl.org/pe-repo/ocde/ford#2.11.01-1Electromagnetic Transducer for In-Line Determination of Alcohol Content in Piscoinfo:eu-repo/semantics/articlereponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/968oai:repositorio.concytec.gob.pe:20.500.12390/9682024-05-30 16:00:13.858http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8943beac-23d8-48b0-a05d-b887240c600d"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco</Title> <PublishedIn> <Publication> <Title>IEEE Sensors Journal</Title> </Publication> </PublishedIn> <PublicationDate>2016</PublicationDate> <DOI>https://doi.org/10.1109/JSEN.2016.2594955</DOI> <ISI-Number>447105600008</ISI-Number> <Authors> <Author> <DisplayName>Santos, EJP</DisplayName> <Person id="rp02648" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Calderon, CHJ</DisplayName> <Person id="rp02647" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>IEEE Sensors Journal</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>Bebida alcohólica</Keyword> <Abstract>A specially designed electromagnetic transmission line is used as an in-line real-time transducer of alcohol content in pisco beverage production. During the distillation process, as the beverage is collected in a tank, it is homogenized, and a sample is continuously pumped into the coaxial line transducer. Pisco is a beverage with 53%-62% water, and 47%-38% alcohol, with 90% of the alcohol content being ethanol. The alcohol content of the flow is detected by measuring the electromagnetic attenuation of the TEM mode propagating inside the transmission line. The propagating mode frequency is selected in the 1-1.5 GHz range, enabling the measurement of alcohol concentration from 0% up to 100%, displaying an almost linear relationship between the alcohol concentration and power absorption in decibels.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 |
| dc.title.none.fl_str_mv |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| title |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| spellingShingle |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco Santos, EJP Bebida alcohólica https://purl.org/pe-repo/ocde/ford#2.11.01 |
| title_short |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| title_full |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| title_fullStr |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| title_full_unstemmed |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| title_sort |
Electromagnetic Transducer for In-Line Determination of Alcohol Content in Pisco |
| author |
Santos, EJP |
| author_facet |
Santos, EJP Calderon, CHJ |
| author_role |
author |
| author2 |
Calderon, CHJ |
| author2_role |
author |
| dc.contributor.author.fl_str_mv |
Santos, EJP Calderon, CHJ |
| dc.subject.none.fl_str_mv |
Bebida alcohólica |
| topic |
Bebida alcohólica https://purl.org/pe-repo/ocde/ford#2.11.01 |
| dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.11.01 |
| description |
A specially designed electromagnetic transmission line is used as an in-line real-time transducer of alcohol content in pisco beverage production. During the distillation process, as the beverage is collected in a tank, it is homogenized, and a sample is continuously pumped into the coaxial line transducer. Pisco is a beverage with 53%-62% water, and 47%-38% alcohol, with 90% of the alcohol content being ethanol. The alcohol content of the flow is detected by measuring the electromagnetic attenuation of the TEM mode propagating inside the transmission line. The propagating mode frequency is selected in the 1-1.5 GHz range, enabling the measurement of alcohol concentration from 0% up to 100%, displaying an almost linear relationship between the alcohol concentration and power absorption in decibels. |
| publishDate |
2016 |
| dc.date.accessioned.none.fl_str_mv |
2024-05-30T23:13:38Z |
| dc.date.available.none.fl_str_mv |
2024-05-30T23:13:38Z |
| dc.date.issued.fl_str_mv |
2016 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12390/968 |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1109/JSEN.2016.2594955 |
| dc.identifier.isi.none.fl_str_mv |
447105600008 |
| url |
https://hdl.handle.net/20.500.12390/968 https://doi.org/10.1109/JSEN.2016.2594955 |
| identifier_str_mv |
447105600008 |
| dc.language.iso.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.none.fl_str_mv |
IEEE Sensors Journal |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
IEEE Sensors Journal |
| publisher.none.fl_str_mv |
IEEE Sensors Journal |
| dc.source.none.fl_str_mv |
reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC |
| instname_str |
Consejo Nacional de Ciencia Tecnología e Innovación |
| instacron_str |
CONCYTEC |
| institution |
CONCYTEC |
| reponame_str |
CONCYTEC-Institucional |
| collection |
CONCYTEC-Institucional |
| repository.name.fl_str_mv |
Repositorio Institucional CONCYTEC |
| repository.mail.fl_str_mv |
repositorio@concytec.gob.pe |
| _version_ |
1854395788402098176 |
| score |
13.966121 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).