Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage

Descripción del Articulo

OBJETIVE: To determine whether there is a difference in the efficacy and tolerance of sublingual misoprostol and oxytocin intramuscularly in the prevention of postpartum hemorrhage. DESIGN: randomized clinical trial conducted in the "Sergio E. Benales" de Lima Hospital, during the period f...

Descripción completa

Detalles Bibliográficos
Autores: Sandoval Paredes, José, Fuentes, Vanesa, Urrutia, Kerine
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.spog:article/419
Enlace del recurso:http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/419
Nivel de acceso:acceso abierto
id 2304-5132_73acbbe15d7b962f4573a6a0dda717e3
oai_identifier_str oai:ojs.spog:article/419
network_acronym_str 2304-5132
repository_id_str .
network_name_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
spelling Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhageMisoprostol sublingual comparado con oxitocina intramuscular en la prevención de la hemorragia pospartoSandoval Paredes, JoséFuentes, VanesaUrrutia, KerineOBJETIVE: To determine whether there is a difference in the efficacy and tolerance of sublingual misoprostol and oxytocin intramuscularly in the prevention of postpartum hemorrhage. DESIGN: randomized clinical trial conducted in the "Sergio E. Benales" de Lima Hospital, during the period from January to October 2003. MATERIALS AND METHODS: The sample consisted of 136 women in labor divided into two groups: group 1, 68 patients were administered 2OOμg misoprostol sublingually and group II, 68 patients were injected with 10 IU oxytocin intramuscularly immediately after expulsion. RESULTS: In the misoprostol group, the average birth and postpartum bleeding time was 18 min 2 sec 486.6 mL; respectively, while the oxytocin 1O min 53 s and 317.12 mL on average, respectively, with statistically significant differences. significant decrease in the average hematocrit value was found before and after misoprostol supplied. By contrast, this difference with oxytocin was found. Misoprostol, 76.5% of patients had at least one cotateral effect, only 22% reported having felt some discomfort with oxytocin. CONCLUSION: In the prevention of postpartum hemorrhage oxytocin intramuscularly is more effective than misoprostol sublingually and has fewer side effects.OBJETIVO: Determinar si existe diferencia en la eficacia y tolerancia del misoprostol por vía sublingual y oxitocina por vía intramuscular en la prevención de la hemorragia posparto. DISEÑO : Ensayo clínico aleatorizado realizado en el Hospital "Sergio E. Benales" de Lima, durante el período de enero a octubre de 2003. MATERIAL Y MÉTODOS: La muestra estuvo conformada por 136 parturientas divididas en dos grupos: al grupo 1, de 68 pacientes, se le administró 2OOµg de misoprostol por vía sublingual y al grupo II, de 68 pacientes, se le inyectó 10 UI de oxitocina por vía intramuscular, inmediatamente después del expulsivo. RESULTADOS: En el grupo de misoprostol, el tiempo promedio de alumbramiento y sangrado posparto fue 18 min 2 s y 486,6 mL; respectivamente, mientras que en el de oxitocina, 1O min 53's y 317,12 mL en promedio, respectivamente, con diferencias estadísticamente significativas. Se encontró disminución significativa en el valor medio de hematocrito antes y después de haberse suministrado misoprostol. Por el contrario, no se encontró esta diferencia con la oxitocina. Con misoprostol, el 76,5% de las pacientes presentó al menos un efecto cotateral, sólo el 22% refirió haber sentido alguna molestia con la oxitocina. CONCLUSIÓN: En la prevención de la hemorragia posparto, la oxitocina por vía intramuscular es más efectiva que el misoprostol por vía sublingual y tiene menos efectos colaterales.Sociedad Peruana de Obstetricia y Ginecología2015-05-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/41910.31403/rpgo.v50i419Revista Peruana de Ginecología y Obstetricia; Vol. 50, Núm. 4 (2004); 212-2162304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/419/387info:eu-repo/semantics/openAccess2021-05-17T15:51:10Zmail@mail.com -
dc.title.none.fl_str_mv Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
Misoprostol sublingual comparado con oxitocina intramuscular en la prevención de la hemorragia posparto
title Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
spellingShingle Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
Sandoval Paredes, José
title_short Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
title_full Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
title_fullStr Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
title_full_unstemmed Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
title_sort Sublingual misoprostol versus intramuscular oxytocin in the prevention of post partum hemorrhage
dc.creator.none.fl_str_mv Sandoval Paredes, José
Fuentes, Vanesa
Urrutia, Kerine
author Sandoval Paredes, José
author_facet Sandoval Paredes, José
Fuentes, Vanesa
Urrutia, Kerine
author_role author
author2 Fuentes, Vanesa
Urrutia, Kerine
author2_role author
author
dc.contributor.none.fl_str_mv

dc.description.none.fl_txt_mv OBJETIVE: To determine whether there is a difference in the efficacy and tolerance of sublingual misoprostol and oxytocin intramuscularly in the prevention of postpartum hemorrhage. DESIGN: randomized clinical trial conducted in the "Sergio E. Benales" de Lima Hospital, during the period from January to October 2003. MATERIALS AND METHODS: The sample consisted of 136 women in labor divided into two groups: group 1, 68 patients were administered 2OOμg misoprostol sublingually and group II, 68 patients were injected with 10 IU oxytocin intramuscularly immediately after expulsion. RESULTS: In the misoprostol group, the average birth and postpartum bleeding time was 18 min 2 sec 486.6 mL; respectively, while the oxytocin 1O min 53 s and 317.12 mL on average, respectively, with statistically significant differences. significant decrease in the average hematocrit value was found before and after misoprostol supplied. By contrast, this difference with oxytocin was found. Misoprostol, 76.5% of patients had at least one cotateral effect, only 22% reported having felt some discomfort with oxytocin. CONCLUSION: In the prevention of postpartum hemorrhage oxytocin intramuscularly is more effective than misoprostol sublingually and has fewer side effects.
OBJETIVO: Determinar si existe diferencia en la eficacia y tolerancia del misoprostol por vía sublingual y oxitocina por vía intramuscular en la prevención de la hemorragia posparto. DISEÑO : Ensayo clínico aleatorizado realizado en el Hospital "Sergio E. Benales" de Lima, durante el período de enero a octubre de 2003. MATERIAL Y MÉTODOS: La muestra estuvo conformada por 136 parturientas divididas en dos grupos: al grupo 1, de 68 pacientes, se le administró 2OOµg de misoprostol por vía sublingual y al grupo II, de 68 pacientes, se le inyectó 10 UI de oxitocina por vía intramuscular, inmediatamente después del expulsivo. RESULTADOS: En el grupo de misoprostol, el tiempo promedio de alumbramiento y sangrado posparto fue 18 min 2 s y 486,6 mL; respectivamente, mientras que en el de oxitocina, 1O min 53's y 317,12 mL en promedio, respectivamente, con diferencias estadísticamente significativas. Se encontró disminución significativa en el valor medio de hematocrito antes y después de haberse suministrado misoprostol. Por el contrario, no se encontró esta diferencia con la oxitocina. Con misoprostol, el 76,5% de las pacientes presentó al menos un efecto cotateral, sólo el 22% refirió haber sentido alguna molestia con la oxitocina. CONCLUSIÓN: En la prevención de la hemorragia posparto, la oxitocina por vía intramuscular es más efectiva que el misoprostol por vía sublingual y tiene menos efectos colaterales.
description OBJETIVE: To determine whether there is a difference in the efficacy and tolerance of sublingual misoprostol and oxytocin intramuscularly in the prevention of postpartum hemorrhage. DESIGN: randomized clinical trial conducted in the "Sergio E. Benales" de Lima Hospital, during the period from January to October 2003. MATERIALS AND METHODS: The sample consisted of 136 women in labor divided into two groups: group 1, 68 patients were administered 2OOμg misoprostol sublingually and group II, 68 patients were injected with 10 IU oxytocin intramuscularly immediately after expulsion. RESULTS: In the misoprostol group, the average birth and postpartum bleeding time was 18 min 2 sec 486.6 mL; respectively, while the oxytocin 1O min 53 s and 317.12 mL on average, respectively, with statistically significant differences. significant decrease in the average hematocrit value was found before and after misoprostol supplied. By contrast, this difference with oxytocin was found. Misoprostol, 76.5% of patients had at least one cotateral effect, only 22% reported having felt some discomfort with oxytocin. CONCLUSION: In the prevention of postpartum hemorrhage oxytocin intramuscularly is more effective than misoprostol sublingually and has fewer side effects.
publishDate 2015
dc.date.none.fl_str_mv 2015-05-05
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/419
10.31403/rpgo.v50i419
url http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/419
identifier_str_mv 10.31403/rpgo.v50i419
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/419/387
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv Revista Peruana de Ginecología y Obstetricia; Vol. 50, Núm. 4 (2004); 212-216
2304-5132
2304-5124
reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
reponame_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
collection Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1700021454551121920
score 13.932913
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).