1
artículo
Publicado 2013
Enlace
Enlace
The objective of the study was to determine the prevalence of antibodies against avian Paramyxovirus type 1 (APMV-1) in backyard turkeys (n=388) in four provinces of Lima, Peru (Lima, Huaral, Huaura, and Barranca). Blood samples were collected from August to December 2008 and analyzed by hemagglutination inhibition test. The resulting seroprevalence was 3.9% as 15/388 turkeys showed antibody titers consistent with a viral challenge of APMV-1. The highest frequency of positive samples (10/15) was observed in the province of Lima, whereas none sample was positive in the Barranca province. It is concluded that backyard turkeys in three provinces of Lima were exposed to some strains of PMVA-l, constituting a reservoir of virus.
2
artículo
Publicado 2013
Enlace
Enlace
El objetivo del presente estudio fue determinar la prevalencia de anticuerpos contra Paramixovirus Aviar Tipo 1 (APMV-1) en pavos de crianza familiar (n=388) en cuatro provincias del departamento de Lima (Lima, Huaral, Huaura y Barranca), Perú. Las mues- tras fueron colectadas durante los meses de agosto a diciembre de 2008, y fueron anali- zadas mediante la prueba serológica de Inhibición de la Hemoaglutinación. Se encontró una prevalencia de 3.9%, observándose que 15/388 pavos presentaron títulos de anticuerpos compatibles a un desafío viral con cepas de campo del PMVA-1. La mayor frecuencia de muestras positivas (10/15) se observó en la provincia de Lima, mientras que no se tuvo muestras positivas en la provincia de Barranca. Se concluye que los pavos de crianza familiar de tres provincias de Lima estuvieron expuestos a alguna cepa de PMVA-l, constituyendo un reservorio del v...
3
artículo
Publicado 1999
Enlace
Enlace
The choice of the attenuation method to characterize the X rays beams used in the calibration of personal dosemeters at the Calibraion and Dosimetry laboratiry of the Peruvian Institute of Nuclear Energy (IPEN). Voltages applied to the X ray tube and the addition of filters have been made according to the publication ANSI No.13. Half value layer, homogeneity coefficient were found with respect to values published in ANSI No.13. Also spectral distributions and their resolutions were determined. Relative differences of 16 and 9% respectively were found in comparison with values calculated by the Montecarlo's Method.
4
artículo
Se desarrolla un método alternativo para la determinación de la dosis absorbida y la energía efectiva de fotones, con distribuciones espectrales desconocidas, que consiste de un sistema “tandem” formado por dos dosímetros termoluminiscentes de diferente dependencia energética. Se utilizan dosímetros termoluminiscentes de LiF: Mg, Ti, CaF2: Dy y un sistema lector Harshaw 3500. Los dosímetros son caracterizados con 90Sr - 90Y, calibrados a la energía de 60Co e irradiados con siete calidades de haces de radiación X, sugeridas por el ANSI No. 13 y el ISO No. 4037. Las respuestas determinadas para cada tipo de dosímetro son ajustadas a una función que depende de la energía efectiva de los fotones. El ajuste se realiza mediante el algoritmo de minimización de Rosenbrock. El modelo matemático utilizado para esta función tiene cinco parámetros de ajuste y está compuesto por ...
5
artículo
Publicado 2002
Enlace
Enlace
El presente estudio se ha determinado los coeficientes de conversión de exposición en aire a dosis equivalente, para fotones de rayos X entre 20 y 75 keV, y para las energías de Cs-137 y Co-60. Los resultados permitirán efectuar la calibración de los dosímetros de vigilancia individual y ambiental, de acuerdo con las recomendaciones de la ICRU 47. Las mediciones fueron realizadas en el Laboratorio de Calibraciones del Instituto Peruano de Energía Nuclear, empleando cámaras de ionización tipo lapicero y fantomas de agua y acrílico. Los valores de los factores de retrodispersión han sido determinados con incertidumbres menores que 6 % para ocho calidades de radiación sugeridas por el ANSI Nº 13.