Influencia del cordón de soldadura en la resistencia a la corrosión del acero API 5L X-70 del proyecto Camisea
Descripción del Articulo
In this work, the influence of weld seams on the corrosion resistance of API 5LX-70 steel _x000D_ from the CAMISEA project was investigated. Using a potentiostatic polarization curve, the _x000D_ corrosion resistance of welded API 5L X-70 steel was evaluated. Three base material _x000D_ corrosion te...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2023 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/16769 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/16769 |
Nivel de acceso: | acceso abierto |
Materia: | Resistencia a la corrosión Cinética de corrosión Acero API 5LX-70 |
Sumario: | In this work, the influence of weld seams on the corrosion resistance of API 5LX-70 steel _x000D_ from the CAMISEA project was investigated. Using a potentiostatic polarization curve, the _x000D_ corrosion resistance of welded API 5L X-70 steel was evaluated. Three base material _x000D_ corrosion test tubes were tested, and three welded test tubes with E7018 electrodes. The _x000D_ corrosion tests were carried out following the ASTM G1-72 standard, evaluated by means _x000D_ of a polarization curve, using the ASTM G5-78 standard, determining the corrosion rate. _x000D_ Tests were carried out which showed that the corrosion was uniform. Welded joint samples _x000D_ were taken using the E7018 electrode and subjected to corrosion tests in seawater. Anodic _x000D_ polarization curves were obtained, which revealed a corrosion rate of 1.5 gr/cm2.year. In _x000D_ addition, corrosion tests were carried out on samples of the base material, which show a _x000D_ corrosion rate of 0.4 gr/cm2.year. The E7018 electrode material was determined to be less _x000D_ corrosion resistant than the base material due to its low root pass penetration |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).