Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection

Descripción del Articulo

OBJETIVES: To evaluate the sensitivity and specifity of a nitrocellulose membrane-based immunoassay for dengue IgM, with respect to capture enzyme immunoassay, for the diagnosis of dengue virus infection. METHODS: 101 serum samples were processed and divided into 2 groups: 53 from dengue serotype 1...

Descripción completa

Detalles Bibliográficos
Autor: León Sandoval, Segundo
Formato: artículo
Fecha de Publicación:1999
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4475
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4475
Nivel de acceso:acceso abierto
Materia:Dengue
Collodion
Immunoassay
IgM
Colodion
Inmunoensayo
id REVUNMSM_b79ce5bc5b3ec5d132548f75cce85c05
oai_identifier_str oai:ojs.csi.unmsm:article/4475
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM DetectionInmunoanálisis Ligado a Enzimas en Membranas de Nitrocelulosa para la Determinacion de IgM en el Diagnóstico de Dengue serotipoLeón Sandoval, SegundoDengueCollodionImmunoassayIgMDengueColodionInmunoensayoIgMOBJETIVES: To evaluate the sensitivity and specifity of a nitrocellulose membrane-based immunoassay for dengue IgM, with respect to capture enzyme immunoassay, for the diagnosis of dengue virus infection. METHODS: 101 serum samples were processed and divided into 2 groups: 53 from dengue serotype 1 (DEN1) infected patients, and 48 from healthy subjects. Both groups were tested with a nitrocellulose membrane-based IgM capture enzyme immunoassay (NMB-EIA) and also with an ELISA as referential pattern. RESULTS: NMB-EIA testing detected IgM anti-DEN1 in 94,34% of samples from infected patients, and in 14,58% of control samples, whereas ELISA fails to report false positive or false negative results. CONCLUSION: NMB-EIA appears to be a good alternative for dengue infection diagnosis.OBJETIVOS: Evaluar la sensibilidad y especificidad de un inmunoensayo en membranas de nitrocelulosa para la determinación de IgM, utilizando como referencia la prueba de inmunoensayo de captura de IgM en placa, para el diagnóstico de dengue. MÉTODOS: Se procesaron 101 muestras de suero divididas en dos grupos: 53 muestras de personas con dengue serotipo 1 (DEN1), y 48 muestras de personas aparentemente sanas. Ambos grupos fueron evaluados por el método de enzimoinmunoensayo en placa (ELISA) como método de referencia y por el método de enzimoinmunoensayo en membranas de nitrocelulosa (EIA-NC). RESULTADOS: Con el método de EIA-NC, se detectaron anticuerpos IgM antiDEN1 en 50 (94,34%) de las muestras de pacientes enfermos y en 7 (14,58%) de las muestras de controles sanos, mientras que con el método de ELISA el total de muestras de pacientes enfermos y el total de muestras de pacientes sanos fueron positivas y negativas, respectivamente. CONCLUSIÓN: El EIA-NC desarrollado parece ser una buena alternativa para el diagnóstico de infección por virus dengue.Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana1999-06-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/447510.15381/anales.v60i2.4475Anales de la Facultad de Medicina; Vol. 60 No. 2 (1999); 110-114Anales de la Facultad de Medicina; Vol. 60 Núm. 2 (1999); 110-1141609-94191025-5583reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4475/3559Derechos de autor 1999 Segundo León Sandovalhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/44752020-04-13T20:54:28Z
dc.title.none.fl_str_mv Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
Inmunoanálisis Ligado a Enzimas en Membranas de Nitrocelulosa para la Determinacion de IgM en el Diagnóstico de Dengue serotipo
title Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
spellingShingle Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
León Sandoval, Segundo
Dengue
Collodion
Immunoassay
IgM
Dengue
Colodion
Inmunoensayo
IgM
title_short Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
title_full Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
title_fullStr Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
title_full_unstemmed Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
title_sort Nitrocellulose Membrane-Based Enzyme-Linked Immunoassay for Dengue Serotype-1 IgM Detection
dc.creator.none.fl_str_mv León Sandoval, Segundo
author León Sandoval, Segundo
author_facet León Sandoval, Segundo
author_role author
dc.subject.none.fl_str_mv Dengue
Collodion
Immunoassay
IgM
Dengue
Colodion
Inmunoensayo
IgM
topic Dengue
Collodion
Immunoassay
IgM
Dengue
Colodion
Inmunoensayo
IgM
description OBJETIVES: To evaluate the sensitivity and specifity of a nitrocellulose membrane-based immunoassay for dengue IgM, with respect to capture enzyme immunoassay, for the diagnosis of dengue virus infection. METHODS: 101 serum samples were processed and divided into 2 groups: 53 from dengue serotype 1 (DEN1) infected patients, and 48 from healthy subjects. Both groups were tested with a nitrocellulose membrane-based IgM capture enzyme immunoassay (NMB-EIA) and also with an ELISA as referential pattern. RESULTS: NMB-EIA testing detected IgM anti-DEN1 in 94,34% of samples from infected patients, and in 14,58% of control samples, whereas ELISA fails to report false positive or false negative results. CONCLUSION: NMB-EIA appears to be a good alternative for dengue infection diagnosis.
publishDate 1999
dc.date.none.fl_str_mv 1999-06-14
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4475
10.15381/anales.v60i2.4475
url https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4475
identifier_str_mv 10.15381/anales.v60i2.4475
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4475/3559
dc.rights.none.fl_str_mv Derechos de autor 1999 Segundo León Sandoval
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 1999 Segundo León Sandoval
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana
dc.source.none.fl_str_mv Anales de la Facultad de Medicina; Vol. 60 No. 2 (1999); 110-114
Anales de la Facultad de Medicina; Vol. 60 Núm. 2 (1999); 110-114
1609-9419
1025-5583
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1795238246258573312
score 13.940932
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).