Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C
Descripción del Articulo
In radiotherapy, it is essential to have an alternative dosimetric system to identify possible errors at some stage of the process. The optically stimulated luminescence (OSL) technology represents a great advance in the detection of radiation in different areas, one of them being in the area of cli...
| Autores: | , , , , , , , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2022 |
| Institución: | Universidad Nacional de Ingeniería |
| Repositorio: | Revistas - Universidad Nacional de Ingeniería |
| Lenguaje: | español |
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/1286 |
| Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/1286 |
| Nivel de acceso: | acceso abierto |
| Materia: | Dosímetro Radioterapia Nanodot Dosimeter Radiation therapy |
| id |
REVUNI_44eb6e17f7f9626f30675c7beaea906e |
|---|---|
| oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/1286 |
| network_acronym_str |
REVUNI |
| network_name_str |
Revistas - Universidad Nacional de Ingeniería |
| repository_id_str |
|
| spelling |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: CCaracterización, calibración y aplicación en radioterapia de un sistema dosimétrico basado en detectores AL2O3: CMárquez Pachas, José FernandoGuzman Calcina, Carmen SandraAymar Alejos, JesusCarrasco Solis, EduardoHerrera Castillo, CarlosPatino Camargo, GaloSolano Salinas, JavierMéndez Velásquez, Juan AbrahamAlva Zavaleta, Rolando JuanVillaverde Herrera, Jessenia BrillitDosímetroRadioterapiaNanodotDosimeterRadiation therapyNanodotIn radiotherapy, it is essential to have an alternative dosimetric system to identify possible errors at some stage of the process. The optically stimulated luminescence (OSL) technology represents a great advance in the detection of radiation in different areas, one of them being in the area of clinical dosimetry. Objective: To implement an alternative dosimetric system, based on OSL technology of carbon-doped aluminum oxide crystals. Material and methods: Al2or3:C detectors called "nanodot", MicroStar reader, ionization chambers (Standard Imaging and PTW Freiburg), electrometers (PTW-Freiburg and MNCNP) and other accessories. Results: The dosimetric - algorithmic procedure, developed for the calculation of the adsorbed dose in the tumor volume, reproduces the dose values with uncertainties less than 2% for a confidence level of 95% and with relative differences less than 5% compared to the values of the absorbed doses prescribed and / or foreseen in radiotherapy treatments. Conclusions: The nanodot detectors represent a viable alternative for the verification of the absorbed dose in the patient during radiotherapeutic practice for the verification of the prescribed dose and imparted by in vivo dosimetry. Its quality to preserve the information, as a physical witness of the procedure, contributes to security in the treatments.En radioterapia es fundamental contar con un sistema dosimétrico alternativo para identificar posibles errores en alguna etapa del proceso. La tecnología de luminiscencia ópticamente estimulada (OSL), representa un gran avance en la detección de radiaciones en diferentes áreas, siendo una de ellas en el área de dosimetría clínica. Objetivo: Implementar un sistema dosimétrico alternativo, basado en la tecnología OSL de cristales de óxido de aluminio dopados con carbono. Material y métodos: Detectores de Al2O3: C denominados "nanodot", lector MicroStar, cámaras de ionización (Standard Imaging y PTW Freiburg), electrómetros (PTW-Freiburg y MNCNP) y demás accesorios. Resultados: El procedimiento dosimétrico - algorítmico, desarrollado para el cálculo de la dosis adsorbida en el volumen tumoral, reproduce los valores de dosis con incertidumbres menores al 2% para un nivel de confianza del 95% y con diferencias relativas menores al 5% en comparación con los valores de las dosis absorbidas prescritas y / o previstas en los tratamientos de radioterapia. Conclusiones: Los detectores nanodot representan una alternativa viable para la realización de la verificación de la dosis absorbida en el paciente durante la práctica radioterapéutica para la verificación de la dosis prescrita e impartida mediante la dosimetría in vivo. Su calidad para preservar la información, como testigo físico del procedimiento, contribuye seguridad en los tratamientos.Universidad Nacional de Ingeniería2022-06-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionMedical physicsFísica Médicaapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/128610.21754/tecnia.v32i1.1286TECNIA; Vol. 32 No. 1 (2022); 37-43TECNIA; Vol. 32 Núm. 1 (2022); 37-432309-04130375-776510.21754/tecnia.v32i1reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/1286/1916Derechos de autor 2022 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/12862025-07-15T00:10:25Z |
| dc.title.none.fl_str_mv |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C Caracterización, calibración y aplicación en radioterapia de un sistema dosimétrico basado en detectores AL2O3: C |
| title |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C |
| spellingShingle |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C Márquez Pachas, José Fernando Dosímetro Radioterapia Nanodot Dosimeter Radiation therapy Nanodot |
| title_short |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C |
| title_full |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C |
| title_fullStr |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C |
| title_full_unstemmed |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C |
| title_sort |
Characterization, calibration and application in radiotherapy of a dosimetric system based on detectors AT2OR3: C |
| dc.creator.none.fl_str_mv |
Márquez Pachas, José Fernando Guzman Calcina, Carmen Sandra Aymar Alejos, Jesus Carrasco Solis, Eduardo Herrera Castillo, Carlos Patino Camargo, Galo Solano Salinas, Javier Méndez Velásquez, Juan Abraham Alva Zavaleta, Rolando Juan Villaverde Herrera, Jessenia Brillit |
| author |
Márquez Pachas, José Fernando |
| author_facet |
Márquez Pachas, José Fernando Guzman Calcina, Carmen Sandra Aymar Alejos, Jesus Carrasco Solis, Eduardo Herrera Castillo, Carlos Patino Camargo, Galo Solano Salinas, Javier Méndez Velásquez, Juan Abraham Alva Zavaleta, Rolando Juan Villaverde Herrera, Jessenia Brillit |
| author_role |
author |
| author2 |
Guzman Calcina, Carmen Sandra Aymar Alejos, Jesus Carrasco Solis, Eduardo Herrera Castillo, Carlos Patino Camargo, Galo Solano Salinas, Javier Méndez Velásquez, Juan Abraham Alva Zavaleta, Rolando Juan Villaverde Herrera, Jessenia Brillit |
| author2_role |
author author author author author author author author author |
| dc.subject.none.fl_str_mv |
Dosímetro Radioterapia Nanodot Dosimeter Radiation therapy Nanodot |
| topic |
Dosímetro Radioterapia Nanodot Dosimeter Radiation therapy Nanodot |
| description |
In radiotherapy, it is essential to have an alternative dosimetric system to identify possible errors at some stage of the process. The optically stimulated luminescence (OSL) technology represents a great advance in the detection of radiation in different areas, one of them being in the area of clinical dosimetry. Objective: To implement an alternative dosimetric system, based on OSL technology of carbon-doped aluminum oxide crystals. Material and methods: Al2or3:C detectors called "nanodot", MicroStar reader, ionization chambers (Standard Imaging and PTW Freiburg), electrometers (PTW-Freiburg and MNCNP) and other accessories. Results: The dosimetric - algorithmic procedure, developed for the calculation of the adsorbed dose in the tumor volume, reproduces the dose values with uncertainties less than 2% for a confidence level of 95% and with relative differences less than 5% compared to the values of the absorbed doses prescribed and / or foreseen in radiotherapy treatments. Conclusions: The nanodot detectors represent a viable alternative for the verification of the absorbed dose in the patient during radiotherapeutic practice for the verification of the prescribed dose and imparted by in vivo dosimetry. Its quality to preserve the information, as a physical witness of the procedure, contributes to security in the treatments. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022-06-30 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Medical physics Física Médica |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1286 10.21754/tecnia.v32i1.1286 |
| url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1286 |
| identifier_str_mv |
10.21754/tecnia.v32i1.1286 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1286/1916 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2022 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2022 TECNIA http://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| dc.source.none.fl_str_mv |
TECNIA; Vol. 32 No. 1 (2022); 37-43 TECNIA; Vol. 32 Núm. 1 (2022); 37-43 2309-0413 0375-7765 10.21754/tecnia.v32i1 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
| instname_str |
Universidad Nacional de Ingeniería |
| instacron_str |
UNI |
| institution |
UNI |
| reponame_str |
Revistas - Universidad Nacional de Ingeniería |
| collection |
Revistas - Universidad Nacional de Ingeniería |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1838636205937262592 |
| score |
13.860459 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).