DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM

Descripción del Articulo

IN RADIOTHERAPY CENTERS, WHERE THERE ARE MORE THAN TWO LINEAR ACCELERATORS (LINACS) OF THE SAME MANUFACTURER AND MODEL, IT IS IMPORTANT TO CONSIDER A DOSIMETRIC PAIRING. FOR THIS REASON, THE INITIATIVE TO COMPARE THE DOSIMETRIC FACTORS OF TWO MODELS OF LINACS SYNERGY (ELEKTA) WITH PHOTONS OF 6 MEV O...

Descripción completa

Detalles Bibliográficos
Autores: PACHECO, JONATHAN W., GUZMÁN, CARMEN S., MÁRQUEZ, JOSÉ F., MÉNDEZ, JUAN A., VILLAVERDE, JESENIA, ALVA, MIRKO S.
Formato: artículo
Fecha de Publicación:2024
Institución:Universidad Nacional del Callao
Repositorio:UNAC-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unac.edu.pe:20.500.12952/9845
Enlace del recurso:https://hdl.handle.net/20.500.12952/9845
Nivel de acceso:acceso abierto
Materia:MONTE CARLO METHOD, PARTICLE ACCELERATORS (SOURCE: DECS BIREME), RADIATION DOSE
https://purl.org/pe-repo/ocde/ford#2.00.00
Descripción
Sumario:IN RADIOTHERAPY CENTERS, WHERE THERE ARE MORE THAN TWO LINEAR ACCELERATORS (LINACS) OF THE SAME MANUFACTURER AND MODEL, IT IS IMPORTANT TO CONSIDER A DOSIMETRIC PAIRING. FOR THIS REASON, THE INITIATIVE TO COMPARE THE DOSIMETRIC FACTORS OF TWO MODELS OF LINACS SYNERGY (ELEKTA) WITH PHOTONS OF 6 MEV OF ENERGY WAS PRESENTED. TOTAL DISPERSION FACTORS, DOSE VARIATION IN THE CENTRAL AXIS, DOSE PROFILE, WEDGE TRANSMISSION FACTORS, AND DOSE RATE WERE CONSIDERED. ABSOLUTE AND RELATIVE MEASUREMENTS WERE MADE WITH 5 IONIZATION CHAMBERS, FLAT DOSE DISTRIBUTIONS WERE OBTAINED WITH AN ARRANGEMENT OF 729 IONIZATION CHAMBERS, AND THE Γ INDEX WAS EVALUATED BY MEPHYSTO SOFTWARE. THE RESULTS OBTAINED WERE DOSE DIFFERENCE VALUES OF LESS THAN 1 %, REPRODUCED DOSE DISTRIBUTIONS WITH A VALUE GREATER THAN 95 % OF THE VOXELS ANALYZED FOR DISTANCE TO AGREEMENT (DTA) OF 2 MM AND ∆ DOSE OF 2 %, BOTH FOR PDD AND FOR EVALUATED PROFILES. THESE RESULTS WERE VALIDATED WITH DATA OBTAINED WITH MONTE CARLO SIMULATION (XVMC). IT WAS CONCLUDED THAT WITH THE METHODOLOGY DEVELOPED IT WAS POSSIBLE TO OBTAIN AN ADEQUATE PAIRING OF BEAMS GENERATED BY TWO DIFFERENT LINACS. © 2024, UNIVERSIDAD NACIONAL DE COLOMBIA. ALL RIGHTS RESERVED.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).