Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study

Descripción del Articulo

Aim: The current study compared the push-out adhesive strength of glass fiber-reinforced posts with a silane-treated surface versus a universally adhesive-treated surface. In both cases, a universal self-adhesive cement was used. Materials and Methods: Thirty bovine teeth were used in an in vitro ex...

Descripción completa

Detalles Bibliográficos
Autores: Martínez-Campos, Reynaldo, Vilchez-Reynaga, Luzmila, Santander-Rengifo, Flor, López-Gurreonero, Carlos, Aliaga-Mariñas, Ana, Aroste-Andía, Rosa, Cayo-Rojas, César
Formato: artículo
Fecha de Publicación:2024
Institución:Universidad Peruana de Ciencias Aplicadas
Repositorio:UPC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorioacademico.upc.edu.pe:10757/675846
Enlace del recurso:http://hdl.handle.net/10757/675846
Nivel de acceso:acceso embargado
Materia:Adhesive Strength
Fiberglass Post
Push-out
Silane
Universal Adhesive
Universal Self-Adhesive Cement
id UUPC_ea7c40c33beb20f4d374a871e2dd5051
oai_identifier_str oai:repositorioacademico.upc.edu.pe:10757/675846
network_acronym_str UUPC
network_name_str UPC-Institucional
repository_id_str 2670
dc.title.es_PE.fl_str_mv Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
title Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
spellingShingle Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
Martínez-Campos, Reynaldo
Adhesive Strength
Fiberglass Post
Push-out
Silane
Universal Adhesive
Universal Self-Adhesive Cement
title_short Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
title_full Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
title_fullStr Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
title_full_unstemmed Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
title_sort Adhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Study
author Martínez-Campos, Reynaldo
author_facet Martínez-Campos, Reynaldo
Vilchez-Reynaga, Luzmila
Santander-Rengifo, Flor
López-Gurreonero, Carlos
Aliaga-Mariñas, Ana
Aroste-Andía, Rosa
Cayo-Rojas, César
author_role author
author2 Vilchez-Reynaga, Luzmila
Santander-Rengifo, Flor
López-Gurreonero, Carlos
Aliaga-Mariñas, Ana
Aroste-Andía, Rosa
Cayo-Rojas, César
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Martínez-Campos, Reynaldo
Vilchez-Reynaga, Luzmila
Santander-Rengifo, Flor
López-Gurreonero, Carlos
Aliaga-Mariñas, Ana
Aroste-Andía, Rosa
Cayo-Rojas, César
dc.subject.es_PE.fl_str_mv Adhesive Strength
Fiberglass Post
Push-out
Silane
Universal Adhesive
Universal Self-Adhesive Cement
topic Adhesive Strength
Fiberglass Post
Push-out
Silane
Universal Adhesive
Universal Self-Adhesive Cement
description Aim: The current study compared the push-out adhesive strength of glass fiber-reinforced posts with a silane-treated surface versus a universally adhesive-treated surface. In both cases, a universal self-adhesive cement was used. Materials and Methods: Thirty bovine teeth were used in an in vitro experiment. Through cutting, the root and coronal sections were divided. Subsequently, the manufacturer’s recommendations were followed for the placement of glass fiber-reinforced posts through root canal therapy, gutta-percha removal, and canal shaping. On the basis of how the posts were treated prior to cementation, the samples were split into three groups (n = 10). Posts in group A (control) did not get any prior treatment. Posts in group B had previously received a silane treatment. Posts in Group C had previously been coated with universal adhesive. Following the application of RelyX Ultimate universal self-adhesive cementation, the samples were segmented and subjected to a Push-Out test at a speed of 1 mm/min on a universal testing apparatus. Intergroup ANOVA was used to evaluate the adhesive strength means (measured in MPa), and Tukey’s post hoc test was performed afterward, with a significance level of P < 0.05. Results: Compared to the glass fiber-reinforced posts pre-treated with silane (P = 0.003) and the control group (P < 0.001), the adhesive strength of the posts pre-treated with universal adhesive was significantly higher. Similarly, the adhesive strength of the glass fiber-reinforced posts that had been pre-treated with silane was considerably higher than that of the control group (P = 0.012). Conclusion: Posts reinforced with glass fiber and pre-treated with universal adhesive exhibited notably greater adhesive strength compared to those pre-treated with silane. When compared to utilizing universal self-adhesive cement without pre-treatment, both pre-treatment techniques greatly increased the adhesive strength of glass fiber-reinforced posts.
publishDate 2024
dc.date.accessioned.none.fl_str_mv 2024-09-24T00:55:11Z
dc.date.available.none.fl_str_mv 2024-09-24T00:55:11Z
dc.date.issued.fl_str_mv 2024-01-01
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.issn.none.fl_str_mv 09767428
dc.identifier.doi.none.fl_str_mv 10.4103/jioh.jioh_42_24
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10757/675846
dc.identifier.eissn.none.fl_str_mv 09761799
dc.identifier.journal.es_PE.fl_str_mv Journal of International Oral Health
dc.identifier.eid.none.fl_str_mv 2-s2.0-85202756474
dc.identifier.scopusid.none.fl_str_mv SCOPUS_ID:85202756474
dc.identifier.isni.none.fl_str_mv 0000 0001 2196 144X
identifier_str_mv 09767428
10.4103/jioh.jioh_42_24
09761799
Journal of International Oral Health
2-s2.0-85202756474
SCOPUS_ID:85202756474
0000 0001 2196 144X
url http://hdl.handle.net/10757/675846
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/embargoedAccess
eu_rights_str_mv embargoedAccess
dc.format.es_PE.fl_str_mv application/html
dc.publisher.es_PE.fl_str_mv Wolters Kluwer Medknow Publications
dc.source.es_PE.fl_str_mv Repositorio Académico - UPC
dc.source.none.fl_str_mv reponame:UPC-Institucional
instname:Universidad Peruana de Ciencias Aplicadas
instacron:UPC
instname_str Universidad Peruana de Ciencias Aplicadas
instacron_str UPC
institution UPC
reponame_str UPC-Institucional
collection UPC-Institucional
dc.source.journaltitle.none.fl_str_mv Journal of International Oral Health
dc.source.volume.none.fl_str_mv 16
dc.source.issue.none.fl_str_mv 4
dc.source.beginpage.none.fl_str_mv 290
dc.source.endpage.none.fl_str_mv 296
bitstream.url.fl_str_mv https://repositorioacademico.upc.edu.pe/bitstream/10757/675846/1/license.txt
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositorio académico upc
repository.mail.fl_str_mv upc@openrepository.com
_version_ 1837187469680836608
spelling 188a231210f8eaeab50f43e0ead8d9c3300b577cc3c8f07fa8bbaec922ed7d39183300487cc5bb1fbcc82f8c8cadbcdf96d6704a5973967af01718ef293a9cff346b64500758b92a24db443b5f882b3fb8a63cf7330060f0a3f0e8e9ac08f41e3fef200fbfd230076eb37dfefb9edf61657b14fd457d847Martínez-Campos, ReynaldoVilchez-Reynaga, LuzmilaSantander-Rengifo, FlorLópez-Gurreonero, CarlosAliaga-Mariñas, AnaAroste-Andía, RosaCayo-Rojas, César2024-09-24T00:55:11Z2024-09-24T00:55:11Z2024-01-010976742810.4103/jioh.jioh_42_24http://hdl.handle.net/10757/67584609761799Journal of International Oral Health2-s2.0-85202756474SCOPUS_ID:852027564740000 0001 2196 144XAim: The current study compared the push-out adhesive strength of glass fiber-reinforced posts with a silane-treated surface versus a universally adhesive-treated surface. In both cases, a universal self-adhesive cement was used. Materials and Methods: Thirty bovine teeth were used in an in vitro experiment. Through cutting, the root and coronal sections were divided. Subsequently, the manufacturer’s recommendations were followed for the placement of glass fiber-reinforced posts through root canal therapy, gutta-percha removal, and canal shaping. On the basis of how the posts were treated prior to cementation, the samples were split into three groups (n = 10). Posts in group A (control) did not get any prior treatment. Posts in group B had previously received a silane treatment. Posts in Group C had previously been coated with universal adhesive. Following the application of RelyX Ultimate universal self-adhesive cementation, the samples were segmented and subjected to a Push-Out test at a speed of 1 mm/min on a universal testing apparatus. Intergroup ANOVA was used to evaluate the adhesive strength means (measured in MPa), and Tukey’s post hoc test was performed afterward, with a significance level of P < 0.05. Results: Compared to the glass fiber-reinforced posts pre-treated with silane (P = 0.003) and the control group (P < 0.001), the adhesive strength of the posts pre-treated with universal adhesive was significantly higher. Similarly, the adhesive strength of the glass fiber-reinforced posts that had been pre-treated with silane was considerably higher than that of the control group (P = 0.012). Conclusion: Posts reinforced with glass fiber and pre-treated with universal adhesive exhibited notably greater adhesive strength compared to those pre-treated with silane. When compared to utilizing universal self-adhesive cement without pre-treatment, both pre-treatment techniques greatly increased the adhesive strength of glass fiber-reinforced posts.Revisión por paresapplication/htmlengWolters Kluwer Medknow Publicationsinfo:eu-repo/semantics/embargoedAccessRepositorio Académico - UPCJournal of International Oral Health164290296reponame:UPC-Institucionalinstname:Universidad Peruana de Ciencias Aplicadasinstacron:UPCAdhesive StrengthFiberglass PostPush-outSilaneUniversal AdhesiveUniversal Self-Adhesive CementAdhesive Strength of Glass Fiber-Reinforced Posts with Silane Conditioning Versus Universal Adhesive System Conditioning: An In Vitro Studyinfo:eu-repo/semantics/articleLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorioacademico.upc.edu.pe/bitstream/10757/675846/1/license.txt8a4605be74aa9ea9d79846c1fba20a33MD51false10757/675846oai:repositorioacademico.upc.edu.pe:10757/6758462024-09-24 00:55:13.205Repositorio académico upcupc@openrepository.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
score 13.873067
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).