In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems

Descripción del Articulo

Objective: To compare the adhesive strength in dentin of three universal adhesive systems in vitro by means of the shear test. Materials and methods: Seventy-five bovine teeth were selected and cut. Dentin was exposed from the buccal surface of the crowns with 220 grit sandpaper, and samples were th...

Descripción completa

Detalles Bibliográficos
Autores: Acurio-Benavente, Mariana, Kinoshita-Rivas, Haru, Acurio-Benavente, Paloma, Casas-Apayco, Leslie
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad Peruana de Ciencias Aplicadas
Repositorio:UPC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorioacademico.upc.edu.pe:10757/624652
Enlace del recurso:http://hdl.handle.net/10757/624652
Nivel de acceso:acceso abierto
Materia:Dentin
Adhesives
Shear strength
id UUPC_0d74ad1701ebe24168c7f2ebcb1bf21c
oai_identifier_str oai:repositorioacademico.upc.edu.pe:10757/624652
network_acronym_str UUPC
network_name_str UPC-Institucional
repository_id_str 2670
dc.title.en_US.fl_str_mv In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
title In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
spellingShingle In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
Acurio-Benavente, Mariana
Dentin
Adhesives
Shear strength
title_short In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
title_full In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
title_fullStr In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
title_full_unstemmed In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
title_sort In vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systems
author Acurio-Benavente, Mariana
author_facet Acurio-Benavente, Mariana
Kinoshita-Rivas, Haru
Acurio-Benavente, Paloma
Casas-Apayco, Leslie
author_role author
author2 Kinoshita-Rivas, Haru
Acurio-Benavente, Paloma
Casas-Apayco, Leslie
author2_role author
author
author
dc.contributor.email.es_PE.fl_str_mv leslie.casas@upc.pe
dc.contributor.author.fl_str_mv Acurio-Benavente, Mariana
Kinoshita-Rivas, Haru
Acurio-Benavente, Paloma
Casas-Apayco, Leslie
dc.subject.en_US.fl_str_mv Dentin
Adhesives
Shear strength
topic Dentin
Adhesives
Shear strength
description Objective: To compare the adhesive strength in dentin of three universal adhesive systems in vitro by means of the shear test. Materials and methods: Seventy-five bovine teeth were selected and cut. Dentin was exposed from the buccal surface of the crowns with 220 grit sandpaper, and samples were then inserted in transparent acrylic bases (15x10mm). The samples were randomly divided in 3 groups (n=25): G1-Universal adhesive system Scotchbond™ Universal (3M ESPE-USA); G2-Universal adhesive system Peak Universal Bond (Ultradent); G3-Universal adhesive system Tetric N-Bond (Ivoclar Vivadent). The adhesive procedures were carried out according to the instructions of each manufacturer and the restorative procedures were carried out with micro-cylinders (made of Tygon type tubing 0.79x1.5mm) of the composite resin Filtek™ Z350XT-A2 (3M ESPE-USA). The samples were incubated at 37ºC (+/-5ºC) for 24 hours. Adhesive strength was evaluated in a universal test machine by means of the shear test (0.5mm/ min, 500N) and the resulting fracture type was evaluated with a Dinolite digital microscope (x200). The results were analyzed by descriptive statistics (Mean±SD), and inferential statistics by a one-way ANOVA. Results: No statistically significant differences were found between the universal adhesive systems evaluated G1 (14.91±4.76), G2 (16.90±4.11) and G3 (17.34±4.04)/(p=0.114). Conclusions: The shear test resulted in similar values of immediate adhesive strength of the three universal adhesive systems used.
publishDate 2018
dc.date.accessioned.none.fl_str_mv 2018-11-27T03:53:36Z
dc.date.available.none.fl_str_mv 2018-11-27T03:53:36Z
dc.date.issued.fl_str_mv 2018-05
dc.type.en_US.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.doi.es_PE.fl_str_mv 10.17126/joralres.2018.044
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10757/624652
dc.identifier.journal.en_US.fl_str_mv Journal of Oral Research
dc.identifier.isni.none.fl_str_mv 0000 0001 2196 144X
identifier_str_mv 10.17126/joralres.2018.044
Journal of Oral Research
0000 0001 2196 144X
url http://hdl.handle.net/10757/624652
dc.language.iso.en_US.fl_str_mv eng
language eng
dc.relation.url.en_US.fl_str_mv http://joralres.com/index.php/JOR/article/view/437/441
dc.rights.en_US.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.en_US.fl_str_mv application/pdf
dc.publisher.en_US.fl_str_mv Universidad de Concepción
dc.source.es_PE.fl_str_mv Repositorio Académico - UPC
dc.source.none.fl_str_mv reponame:UPC-Institucional
instname:Universidad Peruana de Ciencias Aplicadas
instacron:UPC
instname_str Universidad Peruana de Ciencias Aplicadas
instacron_str UPC
institution UPC
reponame_str UPC-Institucional
collection UPC-Institucional
bitstream.url.fl_str_mv https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/4/437-1670-1-PB.pdf.jpg
https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/3/437-1670-1-PB.pdf.txt
https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/2/license.txt
https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/1/437-1670-1-PB.pdf
bitstream.checksum.fl_str_mv 809f0752f894fc020c8528ac702c7165
067c403b29d66c4d62c3bd55afb53118
8a4605be74aa9ea9d79846c1fba20a33
f74d121aeebd198d8d4dd9f44d7a2cd7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio académico upc
repository.mail.fl_str_mv upc@openrepository.com
_version_ 1846065367588274176
spelling Acurio-Benavente, MarianaKinoshita-Rivas, HaruAcurio-Benavente, PalomaCasas-Apayco, Leslieleslie.casas@upc.pe2018-11-27T03:53:36Z2018-11-27T03:53:36Z2018-0510.17126/joralres.2018.044http://hdl.handle.net/10757/624652Journal of Oral Research0000 0001 2196 144XObjective: To compare the adhesive strength in dentin of three universal adhesive systems in vitro by means of the shear test. Materials and methods: Seventy-five bovine teeth were selected and cut. Dentin was exposed from the buccal surface of the crowns with 220 grit sandpaper, and samples were then inserted in transparent acrylic bases (15x10mm). The samples were randomly divided in 3 groups (n=25): G1-Universal adhesive system Scotchbond™ Universal (3M ESPE-USA); G2-Universal adhesive system Peak Universal Bond (Ultradent); G3-Universal adhesive system Tetric N-Bond (Ivoclar Vivadent). The adhesive procedures were carried out according to the instructions of each manufacturer and the restorative procedures were carried out with micro-cylinders (made of Tygon type tubing 0.79x1.5mm) of the composite resin Filtek™ Z350XT-A2 (3M ESPE-USA). The samples were incubated at 37ºC (+/-5ºC) for 24 hours. Adhesive strength was evaluated in a universal test machine by means of the shear test (0.5mm/ min, 500N) and the resulting fracture type was evaluated with a Dinolite digital microscope (x200). The results were analyzed by descriptive statistics (Mean±SD), and inferential statistics by a one-way ANOVA. Results: No statistically significant differences were found between the universal adhesive systems evaluated G1 (14.91±4.76), G2 (16.90±4.11) and G3 (17.34±4.04)/(p=0.114). Conclusions: The shear test resulted in similar values of immediate adhesive strength of the three universal adhesive systems used.Revisión por paresapplication/pdfengUniversidad de Concepciónhttp://joralres.com/index.php/JOR/article/view/437/441info:eu-repo/semantics/openAccessRepositorio Académico - UPCreponame:UPC-Institucionalinstname:Universidad Peruana de Ciencias Aplicadasinstacron:UPCDentinAdhesivesShear strengthIn vitro comparison of the immediate adhesive strength in dentin of three universal adhesive systemsinfo:eu-repo/semantics/article2018-11-27T03:53:36ZTHUMBNAIL437-1670-1-PB.pdf.jpg437-1670-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg129183https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/4/437-1670-1-PB.pdf.jpg809f0752f894fc020c8528ac702c7165MD54falseTEXT437-1670-1-PB.pdf.txt437-1670-1-PB.pdf.txtExtracted texttext/plain21718https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/3/437-1670-1-PB.pdf.txt067c403b29d66c4d62c3bd55afb53118MD53falseLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52falseORIGINAL437-1670-1-PB.pdf437-1670-1-PB.pdfapplication/pdf210348https://repositorioacademico.upc.edu.pe/bitstream/10757/624652/1/437-1670-1-PB.pdff74d121aeebd198d8d4dd9f44d7a2cd7MD51true10757/624652oai:repositorioacademico.upc.edu.pe:10757/6246522019-08-30 08:19:38.21Repositorio académico upcupc@openrepository.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
score 13.905282
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).