Modification of response reduction factors of overhead water tanks based on ductility factor

Descripción del Articulo

In the earthquake-resistant design of overhead tanks, this research dealt with the determination of the response reduction factor applicable to overhead water tanks performing beyond the elastic limit. Eight existing water tanks were selected for the investigation and 127 ground accelerations due to...

Descripción completa

Detalles Bibliográficos
Autores: Pandian, Antony Vimal Paul, Arunachalam, Krishna Prakash, Avudaiappan, Siva, Jasmin, S. Sahaya, Romero, Lenin Miguel Bendezu, Awoyera, Paul O.
Formato: artículo
Fecha de Publicación:2024
Institución:Universidad Peruana de Ciencias Aplicadas
Repositorio:UPC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorioacademico.upc.edu.pe:10757/673686
Enlace del recurso:http://hdl.handle.net/10757/673686
Nivel de acceso:acceso abierto
Materia:Damping ratio
Ground accelerations
Inelastic response spectra
Natural time period
Nonlinear dynamic analysis
Regression analysis
Descripción
Sumario:In the earthquake-resistant design of overhead tanks, this research dealt with the determination of the response reduction factor applicable to overhead water tanks performing beyond the elastic limit. Eight existing water tanks were selected for the investigation and 127 ground accelerations due to 10 Indian earthquakes were selected. The magnitude of the earthquakes selected ranges from 4.5 to 7.2. Initially, 10.16 million nonlinear dynamic data of response reduction factor had been produced using Newmark’s β method by varying parameters. From the results obtained, multi-linear regression analysis was made to arrive at the empirical formula relating the parameters and it was found that ductility factor was the most significant factor among others such as damping ratio, pre-post stiffness ratio, natural period, and soil types, in influencing response reduction factor. Eventually, It is concluded that the values of the response reduction factor to be adopted in the dynamic analysis of Overhead water tanks should be based on the desired value of the ductility factor.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).