A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements

Descripción del Articulo

Objectives: To assess discrepancies in cephalometric measurements from digital lateral radiography and virtual cone-beam computed assisted tomography cephalogram. Materials and methods: Forty digital lateral radiographs and forty virtual cephalograms obtained by cone-beam computed assisted tomograph...

Descripción completa

Detalles Bibliográficos
Autores: Calle-Morocho, Jesica, Morales-Vadillo, Rafael, Guevara-Canale, Janet, Alva-Cuneo, Carlos
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad de San Martín de Porres
Repositorio:USMP-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.usmp.edu.pe:20.500.12727/6268
Enlace del recurso:https://hdl.handle.net/20.500.12727/6268
https://doi.org/10.17126/joralres.2018.076
Nivel de acceso:acceso abierto
Materia:Tomografía computarizada de haz cónico
Cefalometría
Reproducibilidad de los resultados
https://purl.org/pe-repo/ocde/ford#3.02.00
Descripción
Sumario:Objectives: To assess discrepancies in cephalometric measurements from digital lateral radiography and virtual cone-beam computed assisted tomography cephalogram. Materials and methods: Forty digital lateral radiographs and forty virtual cephalograms obtained by cone-beam computed assisted tomography were analyzed, corresponding to forty patients from the nstituto de Diagnóstico Maxilofacial in Lima, Peru. The principal investigator, who had been previously calibrated, made two measurements within a timespan of fifteen days using the analysis of Steiner and the NemoCeph software, and the difference between the obtained measurements was evaluated to determine if it was significant. Results: For digital lateral radiographs the difference varied between 0.00º - 0.45º and 0.01mm - 0.16mm, with statistical significance for distance between Pg and NB for lateral virtual cephalograms between 0.03º - 0.73º and 0.01mm - 0.43mm, with statistical significance for SE distance. The comparison between the two types of image in the first measurement showed a difference of 0.08º - 1.15º and 0.00mm - 1.43mm with statistical significance for four angular measurements and one linear. The comparison between the two types of image in the second measurement showed a difference of 0.13º - 1º and 0.02mm - 1.32mm with a statistically significant difference for three angular and two linear measurements. Conclusions: The difference between the two types of image is minimal; Both evaluated methods can be used effectively.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).