New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers

Descripción del Articulo

The heart of the grid is the power transformer and it is associated to all the electrical chain for distribution, transmission and generation field. Usually the evaluation of the remaining life and condition is based on Furan analysis or dissolved gas analysis (DGA); however, both requires oil sampl...

Descripción completa

Detalles Bibliográficos
Autores: Arias Velásquez, Ricardo Manuel, Pando Ezcurra, Tamara, Vivanco Aldón, Luis Francisco
Formato: objeto de conferencia
Fecha de Publicación:2022
Institución:Universidad Privada Peruano Alemana
Repositorio:UPAL - Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.upal.edu.pe:20.500.14107/84
Enlace del recurso:https://hdl.handle.net/20.500.14107/84
https://doi.org/10.1109/INTERCON55795.2022.9870084
Nivel de acceso:acceso embargado
Materia:Sensores de temperatura
Aislamiento en aceite
Transformadores electrónicos
Modelos matemáticos
https://purl.org/pe-repo/ocde/ford#2.02.01
id UPAL_e9fb5142a943a17ce9b75b4ef6fb3157
oai_identifier_str oai:repositorio.upal.edu.pe:20.500.14107/84
network_acronym_str UPAL
network_name_str UPAL - Institucional
repository_id_str
dc.title.es_PE.fl_str_mv New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
title New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
spellingShingle New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
Arias Velásquez, Ricardo Manuel
Sensores de temperatura
Aislamiento en aceite
Transformadores electrónicos
Modelos matemáticos
https://purl.org/pe-repo/ocde/ford#2.02.01
title_short New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
title_full New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
title_fullStr New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
title_full_unstemmed New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
title_sort New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers
author Arias Velásquez, Ricardo Manuel
author_facet Arias Velásquez, Ricardo Manuel
Pando Ezcurra, Tamara
Vivanco Aldón, Luis Francisco
author_role author
author2 Pando Ezcurra, Tamara
Vivanco Aldón, Luis Francisco
author2_role author
author
dc.contributor.author.fl_str_mv Arias Velásquez, Ricardo Manuel
Pando Ezcurra, Tamara
Vivanco Aldón, Luis Francisco
dc.subject.es_PE.fl_str_mv Sensores de temperatura
Aislamiento en aceite
Transformadores electrónicos
Modelos matemáticos
topic Sensores de temperatura
Aislamiento en aceite
Transformadores electrónicos
Modelos matemáticos
https://purl.org/pe-repo/ocde/ford#2.02.01
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.02.01
description The heart of the grid is the power transformer and it is associated to all the electrical chain for distribution, transmission and generation field. Usually the evaluation of the remaining life and condition is based on Furan analysis or dissolved gas analysis (DGA); however, both requires oil samples; in a zero downtime policy, the continuous evaluation requires an additional equipment as online DGA equipment. Due to this limitation, the alternative is the evaluation of the “hot-spot temperature” (HST) in the transformers, with the sensors available in the oil, and winding; but an online evaluation has not been considered in the international standards as IEC 60076-7. So, this paper develops the mathematical model, algorithms and evaluates in a real case study, an optional method to obtain the HST and its impacts in the remaining life. This methodology is applied to three phase transformer of a 220 kV, 90MVA with YnD11 connection. It is demonstrates the hot-spot in a online platform and the IEC calculation with the accuracy and the restrictions. El corazón de la red es el transformador de potencia y está asociado a toda la cadena eléctrica de distribución, transmisión y campo de generación. Normalmente, la evaluación de la vida útil restante y el estado se basa en el análisis de Furan o el análisis de gases disueltos (DGA); sin embargo, ambos requieren muestras de aceite; en una política de tiempo de inactividad cero, la evaluación continua requiere un equipo adicional como el equipo DGA en línea. Debido a esta limitación, la alternativa es la evaluación de la "temperatura del punto caliente" (HST) en los transformadores, con los sensores disponibles en el aceite; pero una evaluación en línea no se ha considerado en las normas internacionales como la IEC 60076-7. Por lo tanto, este trabajo desarrolla el modelo matemático y los algoritmos, y evalúa en un caso de estudio real, un método opcional para obtener la HST y sus impactos en la vida restante. Esta metodología se aplica a un transformador trifásico de 220 kV, 90MVA con conexión YnD11. Se demuestra el punto caliente (hot-spot) en una plataforma en línea y el cálculo IEC con la precisión y las restricciones.
publishDate 2022
dc.date.accessioned.none.fl_str_mv 2022-09-07T18:15:00Z
dc.date.available.none.fl_str_mv 2022-09-07T18:15:00Z
dc.date.issued.fl_str_mv 2022-09
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
dc.identifier.citation.es_PE.fl_str_mv Arias Velásquez, R.., Pando Ezcurra, T.& Vivanco Aldón, L. F. (2022). New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers. 2022 IEEE XXIX International Conference on Electronics, Electrical Engineering and Computing (INTERCON), 1–4. https://doi.org/10.1109/INTERCON55795.2022.9870084
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14107/84
dc.identifier.journal.es_PE.fl_str_mv 2022 IEEE XXIX International Conference on Electronics, Electrical Engineering and Computing (INTERCON)
dc.identifier.doi.es_PE.fl_str_mv https://doi.org/10.1109/INTERCON55795.2022.9870084
identifier_str_mv Arias Velásquez, R.., Pando Ezcurra, T.& Vivanco Aldón, L. F. (2022). New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers. 2022 IEEE XXIX International Conference on Electronics, Electrical Engineering and Computing (INTERCON), 1–4. https://doi.org/10.1109/INTERCON55795.2022.9870084
2022 IEEE XXIX International Conference on Electronics, Electrical Engineering and Computing (INTERCON)
url https://hdl.handle.net/20.500.14107/84
https://doi.org/10.1109/INTERCON55795.2022.9870084
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/embargoedAccess
eu_rights_str_mv embargoedAccess
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Institute of Electrical an Electronics Engineers
dc.source.es_PE.fl_str_mv Repositorio institucional UPAL
dc.source.none.fl_str_mv reponame:UPAL - Institucional
instname:Universidad Privada Peruano Alemana
instacron:UPAL
instname_str Universidad Privada Peruano Alemana
instacron_str UPAL
institution UPAL
reponame_str UPAL - Institucional
collection UPAL - Institucional
bitstream.url.fl_str_mv http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/1/Arias_Pando_Vivanco%203.pdf
http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/2/license.txt
http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/3/Arias_Pando_Vivanco%203.pdf.txt
http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/4/Arias_Pando_Vivanco%203.pdf.jpg
bitstream.checksum.fl_str_mv 0fc1faf4579cfb6ef766d4dd0e5eec6e
8a4605be74aa9ea9d79846c1fba20a33
ae1a38fa4b9f735bf28cd62d35952875
118286001b12f966de46963669b406b1
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio de la Universidad Privada Peruano Alemana
repository.mail.fl_str_mv repositorio@upal.edu.pe
_version_ 1752940556877561856
spelling Arias Velásquez, Ricardo ManuelPando Ezcurra, TamaraVivanco Aldón, Luis Francisco2022-09-07T18:15:00Z2022-09-07T18:15:00Z2022-09Arias Velásquez, R.., Pando Ezcurra, T.& Vivanco Aldón, L. F. (2022). New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformers. 2022 IEEE XXIX International Conference on Electronics, Electrical Engineering and Computing (INTERCON), 1–4. https://doi.org/10.1109/INTERCON55795.2022.9870084https://hdl.handle.net/20.500.14107/842022 IEEE XXIX International Conference on Electronics, Electrical Engineering and Computing (INTERCON)https://doi.org/10.1109/INTERCON55795.2022.9870084The heart of the grid is the power transformer and it is associated to all the electrical chain for distribution, transmission and generation field. Usually the evaluation of the remaining life and condition is based on Furan analysis or dissolved gas analysis (DGA); however, both requires oil samples; in a zero downtime policy, the continuous evaluation requires an additional equipment as online DGA equipment. Due to this limitation, the alternative is the evaluation of the “hot-spot temperature” (HST) in the transformers, with the sensors available in the oil, and winding; but an online evaluation has not been considered in the international standards as IEC 60076-7. So, this paper develops the mathematical model, algorithms and evaluates in a real case study, an optional method to obtain the HST and its impacts in the remaining life. This methodology is applied to three phase transformer of a 220 kV, 90MVA with YnD11 connection. It is demonstrates the hot-spot in a online platform and the IEC calculation with the accuracy and the restrictions. El corazón de la red es el transformador de potencia y está asociado a toda la cadena eléctrica de distribución, transmisión y campo de generación. Normalmente, la evaluación de la vida útil restante y el estado se basa en el análisis de Furan o el análisis de gases disueltos (DGA); sin embargo, ambos requieren muestras de aceite; en una política de tiempo de inactividad cero, la evaluación continua requiere un equipo adicional como el equipo DGA en línea. Debido a esta limitación, la alternativa es la evaluación de la "temperatura del punto caliente" (HST) en los transformadores, con los sensores disponibles en el aceite; pero una evaluación en línea no se ha considerado en las normas internacionales como la IEC 60076-7. Por lo tanto, este trabajo desarrolla el modelo matemático y los algoritmos, y evalúa en un caso de estudio real, un método opcional para obtener la HST y sus impactos en la vida restante. Esta metodología se aplica a un transformador trifásico de 220 kV, 90MVA con conexión YnD11. Se demuestra el punto caliente (hot-spot) en una plataforma en línea y el cálculo IEC con la precisión y las restricciones.Revisión por paresapplication/pdfengInstitute of Electrical an Electronics Engineersinfo:eu-repo/semantics/embargoedAccessRepositorio institucional UPALreponame:UPAL - Institucionalinstname:Universidad Privada Peruano Alemanainstacron:UPALSensores de temperaturaAislamiento en aceiteTransformadores electrónicosModelos matemáticoshttps://purl.org/pe-repo/ocde/ford#2.02.01New algorithm and mathematical method for an online hot-spot temperature analysis in oil immersed transformersinfo:eu-repo/semantics/conferenceObjectORIGINALArias_Pando_Vivanco 3.pdfArias_Pando_Vivanco 3.pdfEmbargo: 05/09/2024application/pdf1417495http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/1/Arias_Pando_Vivanco%203.pdf0fc1faf4579cfb6ef766d4dd0e5eec6eMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52TEXTArias_Pando_Vivanco 3.pdf.txtArias_Pando_Vivanco 3.pdf.txtExtracted texttext/plain15223http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/3/Arias_Pando_Vivanco%203.pdf.txtae1a38fa4b9f735bf28cd62d35952875MD53THUMBNAILArias_Pando_Vivanco 3.pdf.jpgArias_Pando_Vivanco 3.pdf.jpgGenerated Thumbnailimage/jpeg1887http://repositorio.upal.edu.pe/bitstream/20.500.14107/84/4/Arias_Pando_Vivanco%203.pdf.jpg118286001b12f966de46963669b406b1MD5420.500.14107/84oai:repositorio.upal.edu.pe:20.500.14107/842022-09-08 03:00:08.534Repositorio de la Universidad Privada Peruano Alemanarepositorio@upal.edu.pe
score 13.7211075
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).