Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú

Descripción del Articulo

Soritor is a little city located in tbe Peruvian Amazonian, in the Region of San Martín, with a population of 10000 inhabitants approximately. Her sewer facilities has a stabilization pond scheme which is object of investigation present. Were founded parameters than let to test the purifying efficie...

Descripción completa

Detalles Bibliográficos
Autor: Prada Guadalupe, Alvaro
Formato: tesis de grado
Fecha de Publicación:2005
Institución:Universidad Nacional de San Martin - Tarapoto
Repositorio:UNSM-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unsm.edu.pe:11458/2366
Enlace del recurso:http://hdl.handle.net/11458/2366
Nivel de acceso:acceso abierto
Materia:La PTAR carece de estructuras básicas para el buen funcionamiento.
Evaluar la eficiencia del tratamiento y remoción bacteriana en la Planta de Tratamiento de Aguas Residuales (PT AR) de Sorito.
id UNSM_22fcddc19586a26b821937ffb06d4607
oai_identifier_str oai:repositorio.unsm.edu.pe:11458/2366
network_acronym_str UNSM
network_name_str UNSM-Institucional
repository_id_str
dc.title.es_PE.fl_str_mv Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
title Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
spellingShingle Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
Prada Guadalupe, Alvaro
La PTAR carece de estructuras básicas para el buen funcionamiento.
Evaluar la eficiencia del tratamiento y remoción bacteriana en la Planta de Tratamiento de Aguas Residuales (PT AR) de Sorito.
title_short Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
title_full Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
title_fullStr Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
title_full_unstemmed Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
title_sort Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perú
author Prada Guadalupe, Alvaro
author_facet Prada Guadalupe, Alvaro
author_role author
dc.contributor.advisor.fl_str_mv Ruiz Ríos, Astriht
dc.contributor.author.fl_str_mv Prada Guadalupe, Alvaro
dc.subject.es_PE.fl_str_mv La PTAR carece de estructuras básicas para el buen funcionamiento.
Evaluar la eficiencia del tratamiento y remoción bacteriana en la Planta de Tratamiento de Aguas Residuales (PT AR) de Sorito.
topic La PTAR carece de estructuras básicas para el buen funcionamiento.
Evaluar la eficiencia del tratamiento y remoción bacteriana en la Planta de Tratamiento de Aguas Residuales (PT AR) de Sorito.
description Soritor is a little city located in tbe Peruvian Amazonian, in the Region of San Martín, with a population of 10000 inhabitants approximately. Her sewer facilities has a stabilization pond scheme which is object of investigation present. Were founded parameters than let to test the purifying efficiency and bacterium death obtained from sewage purify plant (SPP) of Soritor. The results show that the SPP haven't minimum structures for a good performance. The average faecal coliform concentration of effiuent (5,4E+o4 NMP/lOOml) is bigger than permissible limits according to General Law of Water and bis bylaws, likewise global treatment efficiency (99,9168 %) is relatively poor. The average faecal coli concentration of receiver water body before discharge point has a bigger concentration (2,2E+o5 NMP/lOOml) than treated sewage effiuent, therefore considerations about to decrease this parameter by these ecosystem is not possible through dilution. Was founded bacterium death velocity (0,44 Vd) for be used as a design and optimizing parameter for SPP's stabilization ponds or future another in the region, through tests in discontinued flow, according Chick's Law, carried out in a facultative first pond. Also was founded the hydraulic dispersion factors for both, primary and secondary ponds, (1,3 lid and 0,98 l/d respectively) with relation to pond geometry, according with first arder equations and mathematic models developed for Yañez (1983). Finally, with respect to results founded and appraised was made a technical proposal in order to improvement and optimize the Soritor's SPP, according with Norm S.090 called Norm of Sewage Treatment Plants ofthe National Construction Regulations and the Law Nº 17752 called General Law of Waters and her bylaws.
publishDate 2005
dc.date.accessioned.none.fl_str_mv 2017-07-19T19:12:47Z
dc.date.available.none.fl_str_mv 2017-07-19T19:12:47Z
dc.date.issued.fl_str_mv 2005
dc.type.en_US.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.citation.es_PE.fl_str_mv Apa
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/11458/2366
identifier_str_mv Apa
url http://hdl.handle.net/11458/2366
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.en_US.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Universidad Nacional de San Martin
dc.source.es_PE.fl_str_mv Universidad Nacional de San Martin
Repositorio de Tesis - UNSM- T
dc.source.none.fl_str_mv reponame:UNSM-Institucional
instname:Universidad Nacional de San Martin - Tarapoto
instacron:UNSM
instname_str Universidad Nacional de San Martin - Tarapoto
instacron_str UNSM
institution UNSM
reponame_str UNSM-Institucional
collection UNSM-Institucional
bitstream.url.fl_str_mv http://repositorio.unsm.edu.pe/bitstream/11458/2366/4/TP_IAMB_00040_2005.pdf.jpg
http://repositorio.unsm.edu.pe/bitstream/11458/2366/1/TP_IAMB_00040_2005.pdf
http://repositorio.unsm.edu.pe/bitstream/11458/2366/2/license.txt
http://repositorio.unsm.edu.pe/bitstream/11458/2366/3/TP_IAMB_00040_2005.pdf.txt
bitstream.checksum.fl_str_mv 9154664c330ff3509f816fad052d9321
63513191d74baaa39878ac4af4fe55bc
c52066b9c50a8f86be96c82978636682
1f92d7de8ed89983a01f707d6272570c
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional de la Universidad
repository.mail.fl_str_mv repositorio@unsm.edu.pe
_version_ 1741962182393856000
spelling Ruiz Ríos, AstrihtPrada Guadalupe, Alvaro2017-07-19T19:12:47Z2017-07-19T19:12:47Z2005Apahttp://hdl.handle.net/11458/2366Soritor is a little city located in tbe Peruvian Amazonian, in the Region of San Martín, with a population of 10000 inhabitants approximately. Her sewer facilities has a stabilization pond scheme which is object of investigation present. Were founded parameters than let to test the purifying efficiency and bacterium death obtained from sewage purify plant (SPP) of Soritor. The results show that the SPP haven't minimum structures for a good performance. The average faecal coliform concentration of effiuent (5,4E+o4 NMP/lOOml) is bigger than permissible limits according to General Law of Water and bis bylaws, likewise global treatment efficiency (99,9168 %) is relatively poor. The average faecal coli concentration of receiver water body before discharge point has a bigger concentration (2,2E+o5 NMP/lOOml) than treated sewage effiuent, therefore considerations about to decrease this parameter by these ecosystem is not possible through dilution. Was founded bacterium death velocity (0,44 Vd) for be used as a design and optimizing parameter for SPP's stabilization ponds or future another in the region, through tests in discontinued flow, according Chick's Law, carried out in a facultative first pond. Also was founded the hydraulic dispersion factors for both, primary and secondary ponds, (1,3 lid and 0,98 l/d respectively) with relation to pond geometry, according with first arder equations and mathematic models developed for Yañez (1983). Finally, with respect to results founded and appraised was made a technical proposal in order to improvement and optimize the Soritor's SPP, according with Norm S.090 called Norm of Sewage Treatment Plants ofthe National Construction Regulations and the Law Nº 17752 called General Law of Waters and her bylaws.Soritor es una pequeña ciudad ubicada en la amazonía peruana, en la Región San Martín, con una población de 10000 habitantes aproximadamente. Su servicio de desagüe tiene un sistema de lagunas de estabilización, objeto de la presente investigación. Se detenninaron parámetros que permitieron evaluar la eficiencia del tratamiento y remoción bacteriana en la Planta de Tratamiento de Aguas Residuales (PT AR) de Soritor. Los resultados muestran lo siguiente. La PTAR carece de estructuras básicas para el buen funcionamiento. La concentración de bacterias coliformes fecales promedio del efluente (5,4E+04 NMP/lOOml) supera los límites máximos permisibles según la Ley General de Aguas. y sus reglamentos. Así mismo, la eficiencia global promedio del tratamiento (99,9168 %) es relativamente baja. La concentración de coliformes fecales promedio en el cuerpo de agua receptor antes de la descarga de los efluentes de la PTAR tiene una concentración (2,2E+05 NMP/lOOml) más alta con respecto a tales efluentes, por lo que el objetivo de disminuir la concentración de colifecales de los efluentes por este ecosistema ya no es posible por dilución. Se determinó la constante de mortalidad bacteriana (0,44 1/d) para usarla como parámetro de diseño y optimización de la PT AR de Soritor y futuras lagunas en la región, realizando pruebas en equilibrio discontinuo, regidas por la Ley de Chick, en una de las lagunas primarias facultativas. También se determinaron los factores de dispersión hidráulica para las lagunas primarias y secundarias (1,3 1/d y 0,98 l/d respectivamente) en función a la geometría de las lagunas, siguiendo las relaciones de primer orden y el modelo matemático desarrollado por Yánez (1983). Sobre la base de lo evaluado y determinado finalmente se elaboró una propuesta técnica de mejoramiento y optimización de la PT AR, formulada en base al cumplimiento de la norma S.090 Plantas de Tratamiento de Aguas Residuales del Reglamento Nacional de Construcciones y la Ley Nº 17752 General de Aguas y sus reglamentos.Tesisapplication/pdfspaUniversidad Nacional de San Martininfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de San MartinRepositorio de Tesis - UNSM- Treponame:UNSM-Institucionalinstname:Universidad Nacional de San Martin - Tarapotoinstacron:UNSMLa PTAR carece de estructuras básicas para el buen funcionamiento.Evaluar la eficiencia del tratamiento y remoción bacteriana en la Planta de Tratamiento de Aguas Residuales (PT AR) de Sorito.Evaluación, Mejoramiento y Optimización de la Planta de Tratamiento de Aguas Residuales de la Ciudad de Soritor, Moyobamba • Perúinfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngeneria AmbientalUniversidad Nacional de San Martin.Facul de EcologiaIngeniero ambientalTitulo ProfesionalTHUMBNAILTP_IAMB_00040_2005.pdf.jpgTP_IAMB_00040_2005.pdf.jpgGenerated Thumbnailimage/jpeg1756http://repositorio.unsm.edu.pe/bitstream/11458/2366/4/TP_IAMB_00040_2005.pdf.jpg9154664c330ff3509f816fad052d9321MD54ORIGINALTP_IAMB_00040_2005.pdfTP_IAMB_00040_2005.pdfapplication/pdf24244862http://repositorio.unsm.edu.pe/bitstream/11458/2366/1/TP_IAMB_00040_2005.pdf63513191d74baaa39878ac4af4fe55bcMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81327http://repositorio.unsm.edu.pe/bitstream/11458/2366/2/license.txtc52066b9c50a8f86be96c82978636682MD52TEXTTP_IAMB_00040_2005.pdf.txtTP_IAMB_00040_2005.pdf.txtExtracted texttext/plain312355http://repositorio.unsm.edu.pe/bitstream/11458/2366/3/TP_IAMB_00040_2005.pdf.txt1f92d7de8ed89983a01f707d6272570cMD5311458/2366oai:repositorio.unsm.edu.pe:11458/23662021-12-20 03:09:31.484Repositorio Institucional de la Universidadrepositorio@unsm.edu.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
score 13.927238
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).