Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía

Descripción del Articulo

Objective: To determine the validity and reliability of the check lists structured clinical examination (OSCE) for the 6th Year students of the Faculty of Medicine of the “Universidad Nacional de Trujillo” in 2011, in evaluating clinical performance of surgical skills of students. Methods: The resea...

Descripción completa

Detalles Bibliográficos
Autor: Chávez Gil, Mario Alberty
Formato: tesis doctoral
Fecha de Publicación:2015
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/5552
Enlace del recurso:https://hdl.handle.net/20.500.14414/5552
Nivel de acceso:acceso abierto
Materia:Validez, Ecoe, Confiabilidad
id UNIT_ea1d4f78172a8cc2e347b20d31fd0c55
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/5552
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_ES.fl_str_mv Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
title Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
spellingShingle Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
Chávez Gil, Mario Alberty
Validez, Ecoe, Confiabilidad
title_short Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
title_full Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
title_fullStr Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
title_full_unstemmed Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
title_sort Confiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugía
author Chávez Gil, Mario Alberty
author_facet Chávez Gil, Mario Alberty
author_role author
dc.contributor.advisor.fl_str_mv Barrantes Cabrera, Moisés
dc.contributor.author.fl_str_mv Chávez Gil, Mario Alberty
dc.subject.es_ES.fl_str_mv Validez, Ecoe, Confiabilidad
topic Validez, Ecoe, Confiabilidad
description Objective: To determine the validity and reliability of the check lists structured clinical examination (OSCE) for the 6th Year students of the Faculty of Medicine of the “Universidad Nacional de Trujillo” in 2011, in evaluating clinical performance of surgical skills of students. Methods: The research was carried out using check lists comparisons of the ten stations of the OSCE in different rotations. The stations used in general surgery patient simulator. In neurosurgery station used a plate computed tomography (CT) and the second used the Glasgow coma scale. In urology station used a patient simulator for renal colic and the second a model for Foley catheter placement. In ophthalmology, a station used a red-eye image and the second patient simulator study of fundus; Otolaryngology, a station used a CT simulator and the second patient assessment hearing test with fork. Results: We found that: the performance of surgical skills of 86 students was satisfactory (average qualification: 16 points); lists the 10 comparisons ECOE tests, in six stations reliability, using the split-half and correction Spearman-Brown, reached levels from 0.33 to 0.90 and four had reliability; as to the validity using Pearson correlation coefficient, Four Seasons had lists of valid comparisons and lists six stations were inaccurate comparisons. For statistical analysis SPSS version 15.0 was used. Conclusions: OSCE list of collations have satisfactory reliability and validity inaccurate. The performance was very satisfactory and the average was 16 points qualifier. Recommendations: Consider the results to reevaluate OSCE stations
publishDate 2015
dc.date.accessioned.none.fl_str_mv 2017-01-09T19:04:18Z
dc.date.available.none.fl_str_mv 2017-01-09T19:04:18Z
dc.date.issued.fl_str_mv 2015
dc.type.es_ES.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/5552
url https://hdl.handle.net/20.500.14414/5552
dc.language.iso.es_ES.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.relation.ispartofseries.none.fl_str_mv TDME/045-046/2015;
dc.rights.es_ES.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.none.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.none.fl_str_mv Universidad Nacional de Trujillo
publisher.none.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_ES.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/0ae836f8-f538-41c2-8b99-30b43a6f5fd3/download
https://dspace.unitru.edu.pe/bitstreams/becbc5de-35bd-4316-b04d-638fd433901b/download
bitstream.checksum.fl_str_mv 08dac88c8278babc0d8b2aaaed224b75
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807289871494021120
spelling Barrantes Cabrera, MoisésChávez Gil, Mario Alberty2017-01-09T19:04:18Z2017-01-09T19:04:18Z2015https://hdl.handle.net/20.500.14414/5552Objective: To determine the validity and reliability of the check lists structured clinical examination (OSCE) for the 6th Year students of the Faculty of Medicine of the “Universidad Nacional de Trujillo” in 2011, in evaluating clinical performance of surgical skills of students. Methods: The research was carried out using check lists comparisons of the ten stations of the OSCE in different rotations. The stations used in general surgery patient simulator. In neurosurgery station used a plate computed tomography (CT) and the second used the Glasgow coma scale. In urology station used a patient simulator for renal colic and the second a model for Foley catheter placement. In ophthalmology, a station used a red-eye image and the second patient simulator study of fundus; Otolaryngology, a station used a CT simulator and the second patient assessment hearing test with fork. Results: We found that: the performance of surgical skills of 86 students was satisfactory (average qualification: 16 points); lists the 10 comparisons ECOE tests, in six stations reliability, using the split-half and correction Spearman-Brown, reached levels from 0.33 to 0.90 and four had reliability; as to the validity using Pearson correlation coefficient, Four Seasons had lists of valid comparisons and lists six stations were inaccurate comparisons. For statistical analysis SPSS version 15.0 was used. Conclusions: OSCE list of collations have satisfactory reliability and validity inaccurate. The performance was very satisfactory and the average was 16 points qualifier. Recommendations: Consider the results to reevaluate OSCE stationsObjetivo: Determinar la validez y confiabilidad de las listas de cotejos del examen clínico objetivo estructurado (ECOE) de los alumnos del 6° Año de la Facultad de Medicina de la Universidad Nacional de Trujillo durante el año 2011, en la evaluación del rendimiento por competencias clínico quirúrgicas de los estudiantes. Material y métodos: La investigación se llevó a cabo utilizando las listas de cotejos de diez estaciones del ECOE en diferentes rotaciones. Las estaciones de cirugía general utilizaron paciente simulador. En neurocirugía una estación utilizó una placa de tomografía axial computarizada (TAC) y la segunda utilizó la escala de Glasgow. En urología una estación utilizó un paciente simulador para cólico renal y la segunda una maqueta para colocación de sonda de Foley. En oftalmología, una estación utilizó una imagen de ojo rojo y la segunda un paciente simulador para estudio de fondo de ojo; en otorrinolaringología, una estación utilizó una tomografía axial computarizada y la segunda un paciente simulador para valoración de prueba auditiva con diapasón. Resultados: Se encontró que: el rendimiento por competencias quirúrgicas de los 86 estudiantes fue muy satisfactorio (calificativo promedio: 16 puntos); de las 10 listas de cotejos de las pruebas de ECOE, en seis estaciones la confiabilidad, utilizando la división por mitades y la corrección de Sperman-Brown, alcanzó niveles de 0.33 a 0.90 y cuatro no tuvieron confiabilidad; en cuanto a la validez que usa el coeficiente de correlación de Pearson, cuatro estaciones tuvieron listas de cotejos válidas y seis estaciones tuvieron listas de cotejos imprecisas. Para el análisis estadístico se utilizó el programa SPSS versión 15.0 Conclusiones: Las listas de cotejos del ECOE cuentan con confiabilidad satisfactoria y validez imprecisa. El rendimiento fue muy satisfactorio y el calificativo promedio fue de 16 puntos Recomendaciones: Considerar los resultados para reevaluar las estaciones del ECOE.spaUniversidad Nacional de TrujilloTDME/045-046/2015;SUNEDUinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUValidez, Ecoe, ConfiabilidadConfiabilidad y validez de las listas de cotejos del exámen clínico objetivo estructurado para el aprendizaje por competencias de cirugíainfo:eu-repo/semantics/doctoralThesisDoctorUniversidad Nacional de Trujillo.Escuela de PostgradoORIGINALTesis doctoral_Mario Alberty Chávez.pdfTesis doctoral_Mario Alberty Chávez.pdfapplication/pdf544120https://dspace.unitru.edu.pe/bitstreams/0ae836f8-f538-41c2-8b99-30b43a6f5fd3/download08dac88c8278babc0d8b2aaaed224b75MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/becbc5de-35bd-4316-b04d-638fd433901b/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/5552oai:dspace.unitru.edu.pe:20.500.14414/55522017-11-15 12:18:34.584http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.971837
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).