Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco
Descripción del Articulo
A plant has been designed for the treatment of municipal wastewater in the District of Santiago de Chuco, using the design methodology according to the National Building Regulations, DS N ° 011-2006-HOUSING, standard OS.090 Water treatment plants Residual; And the Technical Regulation of the Drinkin...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2017 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/9882 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/9882 |
Nivel de acceso: | acceso abierto |
Materia: | Aguas residuales, Tratamiento de aguas residuales, Agua potable |
id |
UNIT_c93f4176dd099f9d4c7fd4762fb6f88a |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/9882 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_PE.fl_str_mv |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
title |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
spellingShingle |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco Paz García, Abraham Eduan Aguas residuales, Tratamiento de aguas residuales, Agua potable |
title_short |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
title_full |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
title_fullStr |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
title_full_unstemmed |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
title_sort |
Diseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chuco |
author |
Paz García, Abraham Eduan |
author_facet |
Paz García, Abraham Eduan Ruíz Valderrama, Manuel Elvis |
author_role |
author |
author2 |
Ruíz Valderrama, Manuel Elvis |
author2_role |
author |
dc.contributor.advisor.fl_str_mv |
Moreno Eustaquio, Walter |
dc.contributor.author.fl_str_mv |
Paz García, Abraham Eduan Ruíz Valderrama, Manuel Elvis |
dc.subject.es_PE.fl_str_mv |
Aguas residuales, Tratamiento de aguas residuales, Agua potable |
topic |
Aguas residuales, Tratamiento de aguas residuales, Agua potable |
description |
A plant has been designed for the treatment of municipal wastewater in the District of Santiago de Chuco, using the design methodology according to the National Building Regulations, DS N ° 011-2006-HOUSING, standard OS.090 Water treatment plants Residual; And the Technical Regulation of the Drinking Water and Basic Sanitation Sector, RAS-2000, as a complementary methodology. It began with the compilation of necessary bibliographical information, projection of populations, and methodology of design of treatment units, among others. Subsequently, the flow measurements were taken to determine the sampling protocols that were between 11:00 and 13:00 hours; (BOD5, STD, SS, COD, conductivity, oils and grease, pH, Temperature), the results of which are referential, due to the fact that there is some uncertainty in The means for conducting the analyzes. Following the design methodology mentioned, and based on the reference values obtained in the characterization, the type of treatment, which is by activated sludge, was determined, and the treatment systems that would be included; And then, in Excel books, we proceeded to size each of the physical units: Incoming channel, degenerator and grids as pretreatment; Primary settler as primary treatment; And the active sludge system and drying bed as secondary treatments; The same ones, which were drawn in the AutoCAD program at the basic plane level. The location of the project was also suggested based on the Technical Regulations of the Water Supply and Sanitation Sector. The efficiency of removal of BOD5 from the proposed plant is 94%, a range that complies with what is established by the regulations; in addition, it is suggested complementary studies to determine some alterations in the operation of the process because it is relatively new in the environment |
publishDate |
2017 |
dc.date.accessioned.none.fl_str_mv |
2018-02-28T17:04:06Z |
dc.date.available.none.fl_str_mv |
2018-02-28T17:04:06Z |
dc.date.issued.fl_str_mv |
2017 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/9882 |
url |
https://hdl.handle.net/20.500.14414/9882 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/336a3110-5ef8-4707-a4ff-07e454769cfa/download https://dspace.unitru.edu.pe/bitstreams/c1fb7625-7085-4b5d-91fe-de0e1e81cdaa/download |
bitstream.checksum.fl_str_mv |
3cea0f2b86ccbe6b916c4b1870684900 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807289889353367552 |
spelling |
Moreno Eustaquio, WalterPaz García, Abraham EduanRuíz Valderrama, Manuel Elvis2018-02-28T17:04:06Z2018-02-28T17:04:06Z2017https://hdl.handle.net/20.500.14414/9882A plant has been designed for the treatment of municipal wastewater in the District of Santiago de Chuco, using the design methodology according to the National Building Regulations, DS N ° 011-2006-HOUSING, standard OS.090 Water treatment plants Residual; And the Technical Regulation of the Drinking Water and Basic Sanitation Sector, RAS-2000, as a complementary methodology. It began with the compilation of necessary bibliographical information, projection of populations, and methodology of design of treatment units, among others. Subsequently, the flow measurements were taken to determine the sampling protocols that were between 11:00 and 13:00 hours; (BOD5, STD, SS, COD, conductivity, oils and grease, pH, Temperature), the results of which are referential, due to the fact that there is some uncertainty in The means for conducting the analyzes. Following the design methodology mentioned, and based on the reference values obtained in the characterization, the type of treatment, which is by activated sludge, was determined, and the treatment systems that would be included; And then, in Excel books, we proceeded to size each of the physical units: Incoming channel, degenerator and grids as pretreatment; Primary settler as primary treatment; And the active sludge system and drying bed as secondary treatments; The same ones, which were drawn in the AutoCAD program at the basic plane level. The location of the project was also suggested based on the Technical Regulations of the Water Supply and Sanitation Sector. The efficiency of removal of BOD5 from the proposed plant is 94%, a range that complies with what is established by the regulations; in addition, it is suggested complementary studies to determine some alterations in the operation of the process because it is relatively new in the environmentSe ha diseñado una planta para el tratamiento de las aguas residuales municipales del Distrito de Santiago de Chuco, utilizando la metodología de diseños según el Reglamento Nacional de Edificaciones, D.S. N° 011-2006-VIVIENDA, norma OS.090 Plantas de tratamiento de aguas residuales; y el Reglamento Técnico del Sector de Agua Potable y Saneamiento Básico, RAS- 2000, como metodología complementaria. Se inició con la recopilación de la información bibliográfica necesaria, proyección de poblaciones, metodología de diseño de las unidades de tratamiento, entre otros. Posteriormente, se realizó la medición de los caudales para determinar los protocolos de muestreo que fueron entre las 11:00 y las 13:00 horas; luego, se hizo la caracterización de las aguas residuales con análisis de parámetros físico y químicos fundamentales (DBO5, STD, SS, DQO, conductividad, aceites y grasas, pH, Temperatura), cuyos resultados son referenciales, debido a que hay cierta incertidumbre en el medio para la realización de los análisis. Siguiendo la metodología de diseño mencionada, y a partir de los valores referenciales obtenidos en la caracterización, se determinó el tipo de tratamiento, que es por lodos activados, y los sistemas de tratamiento que se incluirían; y luego, en libros de Excel se procedió a dimensionar cada una de las unidades físicas: Canal de llegada, desarenador y rejillas como pretratamiento; sedimentador primario como tratamiento primario; y el sistema de lodos activos y lecho de secado como tratamientos secundarios; los mismos, que fueron dibujados en el programa AutoCAD a nivel de plano básico. Se sugirió, también, el lugar de ubicación del proyecto en base al Reglamento Técnico del Sector de Agua Potable y Saneamiento Básico. La eficiencia de remoción de DBO5 de la planta propuesta es de 94%, rango que cumple con lo establecido por la normatividad, además, se sugiere estudios complementarios para determinar algunas alteraciones en el funcionamiento del proceso por ser relativamente nuevo en el medioTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUAguas residuales, Tratamiento de aguas residuales, Agua potableDiseño de una planta de tratamiento de aguas residuales municipales para el distrito de Santiago de Chucoinfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngeniero AmbientalIngeniería AmbientalUniversidad Nacional de Trujillo.Facultad de Ingeniería QuímicaORIGINALPazGarcia_A - RuizValderrama_M.pdfPazGarcia_A - RuizValderrama_M.pdfapplication/pdf6043706https://dspace.unitru.edu.pe/bitstreams/336a3110-5ef8-4707-a4ff-07e454769cfa/download3cea0f2b86ccbe6b916c4b1870684900MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/c1fb7625-7085-4b5d-91fe-de0e1e81cdaa/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/9882oai:dspace.unitru.edu.pe:20.500.14414/98822018-02-28 12:04:06.376http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.949348 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).