Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos
Descripción del Articulo
BACKGROUND: Total intravenous anesthesia is a general anesthesia technique in which drugs exclusively administered intravenously in the absence of any anesthetic agent inhaled. It has been successfully used in neurosurgery, because it has a minimal effect on intracerebral pressure and provide good h...
Autor: | |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2016 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/3599 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/3599 |
Nivel de acceso: | acceso abierto |
Materia: | Pacientes neuroquirúrgicos, Trujillo, Inestabilidad hemodinámica, Anestesia total intravenosa |
id |
UNIT_c56a1698dc876fd9fe0e5137c1810ce2 |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/3599 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_ES.fl_str_mv |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
title |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
spellingShingle |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos Castillo Benites, Carlos Miguel Pacientes neuroquirúrgicos, Trujillo, Inestabilidad hemodinámica, Anestesia total intravenosa |
title_short |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
title_full |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
title_fullStr |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
title_full_unstemmed |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
title_sort |
Frecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicos |
author |
Castillo Benites, Carlos Miguel |
author_facet |
Castillo Benites, Carlos Miguel |
author_role |
author |
dc.contributor.advisor.fl_str_mv |
García Pérez, Guillermo Arturo |
dc.contributor.author.fl_str_mv |
Castillo Benites, Carlos Miguel |
dc.subject.es_ES.fl_str_mv |
Pacientes neuroquirúrgicos, Trujillo, Inestabilidad hemodinámica, Anestesia total intravenosa |
topic |
Pacientes neuroquirúrgicos, Trujillo, Inestabilidad hemodinámica, Anestesia total intravenosa |
description |
BACKGROUND: Total intravenous anesthesia is a general anesthesia technique in which drugs exclusively administered intravenously in the absence of any anesthetic agent inhaled. It has been successfully used in neurosurgery, because it has a minimal effect on intracerebral pressure and provide good hemodynamic stability OBJECTIVE: To determine the frequency of instability mean arterial pressure in adults neurosurgical using total intravenous anesthesia. MATERIALS AND METHODS: Transversal and descriptive study of 11 adults between 17-65 years of age recruited by random sampling underwent neurosurgery operating room HRDT. Hemodynamic instability was determined when the values of mean arterial pressure were not found within parameters established in previous studies. RESULTS: 27% of hemodynamic instability was found during the anesthetic induction, of which 33.3% are hypertensive events and 66.7% of hypotensive events, without mixed events; however it not presented hemodynamic instability during the anesthetic maintenance. Variability in MAP was recorded on induction between 50 and 106.7 mmHg and maintenance was between 60 and 107 mmHg. CONCLUSIONS: 27% of patients had hemodynamic instability events during anesthetic induction; however, variations in MAP, failed to theoretically affect ranges cerebral autoregulation. |
publishDate |
2016 |
dc.date.accessioned.none.fl_str_mv |
2016-10-17T23:17:23Z |
dc.date.available.none.fl_str_mv |
2016-10-17T23:17:23Z |
dc.date.issued.fl_str_mv |
2016 |
dc.type.es_ES.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/3599 |
url |
https://hdl.handle.net/20.500.14414/3599 |
dc.language.iso.es_ES.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_ES.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.none.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_ES.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_ES.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/a6772e04-b0ea-42b3-aa1d-4b9d65118d45/download https://dspace.unitru.edu.pe/bitstreams/99168675-ca49-4018-ba78-7874bef8efeb/download |
bitstream.checksum.fl_str_mv |
b19b528097269566f9ba35aa2c7e8dd0 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807289675932499968 |
spelling |
García Pérez, Guillermo ArturoCastillo Benites, Carlos Miguel2016-10-17T23:17:23Z2016-10-17T23:17:23Z2016https://hdl.handle.net/20.500.14414/3599BACKGROUND: Total intravenous anesthesia is a general anesthesia technique in which drugs exclusively administered intravenously in the absence of any anesthetic agent inhaled. It has been successfully used in neurosurgery, because it has a minimal effect on intracerebral pressure and provide good hemodynamic stability OBJECTIVE: To determine the frequency of instability mean arterial pressure in adults neurosurgical using total intravenous anesthesia. MATERIALS AND METHODS: Transversal and descriptive study of 11 adults between 17-65 years of age recruited by random sampling underwent neurosurgery operating room HRDT. Hemodynamic instability was determined when the values of mean arterial pressure were not found within parameters established in previous studies. RESULTS: 27% of hemodynamic instability was found during the anesthetic induction, of which 33.3% are hypertensive events and 66.7% of hypotensive events, without mixed events; however it not presented hemodynamic instability during the anesthetic maintenance. Variability in MAP was recorded on induction between 50 and 106.7 mmHg and maintenance was between 60 and 107 mmHg. CONCLUSIONS: 27% of patients had hemodynamic instability events during anesthetic induction; however, variations in MAP, failed to theoretically affect ranges cerebral autoregulation.ANTECEDENTES: La anestesia total intravenosa es una técnica de anestesia general en la cual se administra medi¬camentos exclusivamente por vía intrave¬nosa en ausencia de cualquier agente anes¬tésico inhalado. Se ha utilizado de manera satisfactoria en neurocirugía, debido a que tiene un efecto mínimo sobre la Presión intracraneal y proporcionan buena estabilidad hemodinámica. OBJETIVO: Determinar la frecuencia de inestabilidad de la Presión Arterial Media en adultos neuroquirúrgicos utilizando Anestesia Total Intravenosa MATERIALES Y MÉTODOS: Estudio transversal y descriptivo de 11 Adultos entre 17 a 65 años de edad, que fueron sometidos a neurocirugía en sala de operaciones del HRDT. Se determinó inestabilidad hemodinámica cuando los valores de Presión Arterial Media no se encontraron dentro parámetros establecidos en estudios previos. RESULTADOS: Se encontró 27% de inestabilidad hemodinámica durante el periodo de inducción anestésica, de los cuales el 33.3% corresponden a eventos hipertensivos y 66.7% a eventos hipotensivos, sin eventos mixtos; sin embargo no se presentó inestabilidad hemodinámica durante el mantenimiento anestésico. La variabilidad de la PAM registrada en la inducción fue entre 50 y 106.7 mmHg y en el mantenimiento fue entre 60 y 107 mmHg. CONCLUSIONES: El 27% de los pacientes presentaron eventos de inestabilidad hemodinámica durante la inducción anestésica; sin embargo, las variaciones de la PAM, no llegaron a rangos que afectarán teóricamente la autorregulación cerebral.spaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUPacientes neuroquirúrgicos, Trujillo, Inestabilidad hemodinámica, Anestesia total intravenosaFrecuencia de inestabilidad hemodinámica utilizando anestesia total intravenosa en adultos neuroquirúrgicosinfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalMédico CirujanoMedicinaUniversidad Nacional de Trujillo.Facultad de MedicinaORIGINALCastilloBenites_C.pdfCastilloBenites_C.pdfBachiller en Medicinaapplication/pdf685187https://dspace.unitru.edu.pe/bitstreams/a6772e04-b0ea-42b3-aa1d-4b9d65118d45/downloadb19b528097269566f9ba35aa2c7e8dd0MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/99168675-ca49-4018-ba78-7874bef8efeb/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/3599oai:dspace.unitru.edu.pe:20.500.14414/35992017-12-01 10:40:32.21http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.949927 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).