Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional
Descripción del Articulo
At present, most of the buildings in the country are constructed without any technical criteria, omitting different factors that should be the subject of analysis to have safer and more durable structures over time, this type of buildings are called informal or self-construction, which use aggregate...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2019 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/14758 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/14758 |
Nivel de acceso: | acceso abierto |
Materia: | Agregados en el hormigon y la dosificacion con cemento |
id |
UNIT_3e4f01cd34fed125a5d23478be395c28 |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/14758 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_PE.fl_str_mv |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
title |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
spellingShingle |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional Soto Prado, Marco Antonio Agregados en el hormigon y la dosificacion con cemento |
title_short |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
title_full |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
title_fullStr |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
title_full_unstemmed |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
title_sort |
Influencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencional |
author |
Soto Prado, Marco Antonio |
author_facet |
Soto Prado, Marco Antonio Villegas Ponce, Kevin Deyvis |
author_role |
author |
author2 |
Villegas Ponce, Kevin Deyvis |
author2_role |
author |
dc.contributor.advisor.fl_str_mv |
Vasquez Alfaro, Iván Eugenio |
dc.contributor.author.fl_str_mv |
Soto Prado, Marco Antonio Villegas Ponce, Kevin Deyvis |
dc.subject.es_PE.fl_str_mv |
Agregados en el hormigon y la dosificacion con cemento |
topic |
Agregados en el hormigon y la dosificacion con cemento |
description |
At present, most of the buildings in the country are constructed without any technical criteria, omitting different factors that should be the subject of analysis to have safer and more durable structures over time, this type of buildings are called informal or self-construction, which use aggregates from different quarries, whose physical, chemical and mechanical properties are not known; in addition, many times for the elaboration of structural concrete hormigon is used that is a combination of gravel and sand in similar proportions as replacement of the aggregates classified because it is a more economic material, but that does not generate the levels of resistance desired in the concrete. The purpose of the investigation was to determine the optimal proportion of aggregates in the hormigon and at the same time their best dosage with cement, taking into account the expected resistance; for this purpose, proportions of 50-50 (A1), 60-40 (A2) and 70-30 (A3) were established in percentages of gravel with a maximum nominal size of 1" and sand with a fineness modulus of 2.4 respectively. Dosages were worked from 1:5 (B1) to 1:10 (B6) of cement: concrete (C:H), using red Mochica cement for general use. It is a question of giving an applicative approach to be used in field because the information is limited when working with proportions and dosages in volumetric quantities, generating a suitable recommendation for masters of work in self-construction on the quantities necessary to obtain good physical and mechanical properties of the concrete (unit weight and compression). Cylindrical concrete specimens (ASTM C31) of 15 x 30 cm, tested to compression (ASTM C39) and unit weight (ASTM C642) were formed. Specimens were tested at an age of 7, 14 and 28 days. The optimal design of concrete in volumetric proportions of cement and hormigon that fulfills the minimum resistance for structural elements was reached in the dosage 1:5, for a concrete with hormigon of proportions 70-30 in percentages of gravel and sand respectively, reaching a maximum value of 194 kg/cm2; however, the lightest concrete was achieved in the dosage 1:10 for the proportion 50-50 in percentages of gravel and sand, reaching a unit weight of 2272 kg/m3. |
publishDate |
2019 |
dc.date.accessioned.none.fl_str_mv |
2019-10-21T15:29:39Z |
dc.date.available.none.fl_str_mv |
2019-10-21T15:29:39Z |
dc.date.issued.fl_str_mv |
2019-10 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/14758 |
url |
https://hdl.handle.net/20.500.14414/14758 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.relation.ispartofseries.none.fl_str_mv |
Tciv;Tciv |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/af77db1c-b9f4-4be4-b8dc-e9d05ee96c53/download https://dspace.unitru.edu.pe/bitstreams/e282ed46-3cc1-4944-a1e1-816c815ed66a/download |
bitstream.checksum.fl_str_mv |
8c5c99d182fcf941c16fc9ce953d9522 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807290400458670080 |
spelling |
Vasquez Alfaro, Iván EugenioSoto Prado, Marco AntonioVillegas Ponce, Kevin Deyvis2019-10-21T15:29:39Z2019-10-21T15:29:39Z2019-10https://hdl.handle.net/20.500.14414/14758At present, most of the buildings in the country are constructed without any technical criteria, omitting different factors that should be the subject of analysis to have safer and more durable structures over time, this type of buildings are called informal or self-construction, which use aggregates from different quarries, whose physical, chemical and mechanical properties are not known; in addition, many times for the elaboration of structural concrete hormigon is used that is a combination of gravel and sand in similar proportions as replacement of the aggregates classified because it is a more economic material, but that does not generate the levels of resistance desired in the concrete. The purpose of the investigation was to determine the optimal proportion of aggregates in the hormigon and at the same time their best dosage with cement, taking into account the expected resistance; for this purpose, proportions of 50-50 (A1), 60-40 (A2) and 70-30 (A3) were established in percentages of gravel with a maximum nominal size of 1" and sand with a fineness modulus of 2.4 respectively. Dosages were worked from 1:5 (B1) to 1:10 (B6) of cement: concrete (C:H), using red Mochica cement for general use. It is a question of giving an applicative approach to be used in field because the information is limited when working with proportions and dosages in volumetric quantities, generating a suitable recommendation for masters of work in self-construction on the quantities necessary to obtain good physical and mechanical properties of the concrete (unit weight and compression). Cylindrical concrete specimens (ASTM C31) of 15 x 30 cm, tested to compression (ASTM C39) and unit weight (ASTM C642) were formed. Specimens were tested at an age of 7, 14 and 28 days. The optimal design of concrete in volumetric proportions of cement and hormigon that fulfills the minimum resistance for structural elements was reached in the dosage 1:5, for a concrete with hormigon of proportions 70-30 in percentages of gravel and sand respectively, reaching a maximum value of 194 kg/cm2; however, the lightest concrete was achieved in the dosage 1:10 for the proportion 50-50 in percentages of gravel and sand, reaching a unit weight of 2272 kg/m3.En la actualidad, gran parte de edificaciones en el país se construyen sin ningún criterio técnico, omitiendo diferentes factores que deberían ser materia de análisis para tener estructuras más seguras y durables en el tiempo, este tipo de edificaciones son llamadas informales o autoconstrucción, las cuales usan agregados de diferentes canteras, de los que no se conocen sus propiedades físicas, químicas y mecánicas; además, muchas veces para la elaboración de concreto estructural se usa hormigón que es una combinación de grava y arena en proporciones similares como remplazo de los agregados clasificados debido a que es un material más económico, pero que no genera los niveles de resistencia deseados en el concreto. El propósito de la investigación fue determinar la óptima proporción de los agregados en el hormigón y al mismo tiempo su mejor dosificación con cemento, tomando en cuenta la resistencia esperada; para esto se estableció proporciones de 50-50 (A1), 60-40 (A2) y 70-30 (A3) en porcentajes de grava de tamaño máximo nominal de 1” y arena con módulo de finura 2.4 respectivamente. Se trabajó dosificaciones desde 1:5 (B1) hasta 1:10 (B6) de cemento: hormigón (C:H), utilizando cemento Mochica rojo de uso general. Se trata de dar un enfoque aplicativo a emplearse en campo porque la información es limitada cuando se trabaja con proporciones y dosificaciones en cantidades volumétricas, generando una recomendación adecuada para maestros de obra en autoconstrucción sobre las cantidades necesarias para obtener buenas propiedades físicas y mecánicas del concreto (peso unitario y compresión). Se conformaron probetas cilíndricas de concreto (ASTM C31) de 15 x 30 cm, ensayadas a compresión (ASTM C39) y peso unitario (ASTM C642). Las probetas fueron ensayadas a una edad de 7, 14 y 28 días. El diseño óptimo de concreto en proporciones volumétricas de cemento y hormigón que cumple la resistencia mínima para elementos estructurales se alcanzó en la dosificación 1:5, para un concreto con hormigón de proporciones 70-30 en porcentajes de grava y arena respectivamente, llegando a un valor máximo de 194 kg/cm2; sin embargo, el concreto más ligero se logró en la dosificación 1:10 para la proporción 50-50 en porcentajes grava y arena, alcanzando un peso unitario de 2272 kg/m3.TesisspaUniversidad Nacional de TrujilloTciv;TcivSUNEDUinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUAgregados en el hormigon y la dosificacion con cementoInfluencia de las proporciones de los agregados en el hormigón y la dosificación con cemento sobre el peso unitario y compresión en un concreto convencionalinfo:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero CivilIngenieraUniversidad Nacional de Trujillo. Facultad de IngenieríaORIGINALSOTO PRADO, Marco Antonio; VILLEGAS PONCE, Kevin Deyvis.pdfSOTO PRADO, Marco Antonio; VILLEGAS PONCE, Kevin Deyvis.pdfCementoapplication/pdf8965772https://dspace.unitru.edu.pe/bitstreams/af77db1c-b9f4-4be4-b8dc-e9d05ee96c53/download8c5c99d182fcf941c16fc9ce953d9522MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/e282ed46-3cc1-4944-a1e1-816c815ed66a/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/14758oai:dspace.unitru.edu.pe:20.500.14414/147582019-10-21 10:29:39.787http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.871978 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).