Repotenciación y automatización de equipo mezclador multipropósito

Descripción del Articulo

This thesis had as its general objective the repowering and automation of a multipurpose mixing equipment, which consisted of: 3 hoppers, 1 reservoir tank, 1 mixing and heating tank, and 6 actuators (3 solenoid valves, 1 pump, 1 agitator, and 1 heater). To achieve this objective, a PLC Zelio Logic S...

Descripción completa

Detalles Bibliográficos
Autores: Cadillo Vela, Julio Germán, Gil Gil, Lenin
Formato: tesis de grado
Fecha de Publicación:2025
Institución:Universidad Nacional De La Amazonía Peruana
Repositorio:UNAPIquitos-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unapiquitos.edu.pe:20.500.12737/11195
Enlace del recurso:https://hdl.handle.net/20.500.12737/11195
Nivel de acceso:acceso abierto
Materia:Control automático
Potencia (mécanica)
Automatización
Mezcladora
https://purl.org/pe-repo/ocde/ford#2.02.03
Descripción
Sumario:This thesis had as its general objective the repowering and automation of a multipurpose mixing equipment, which consisted of: 3 hoppers, 1 reservoir tank, 1 mixing and heating tank, and 6 actuators (3 solenoid valves, 1 pump, 1 agitator, and 1 heater). To achieve this objective, a PLC Zelio Logic SR2 B201 FU was implemented on the mixing equipment, on which a control circuit was programmed using Zelio Soft2 V5.4.2. The physical inputs and outputs used from the PLC were: 12 inputs and 6 physical outputs. The pump, agitator, three solenoid valves, and heater were connected to physical outputs Q1, Q2, Q3, Q4, Q5, and Q6, respectively. Data transfer between a PC and the PLC was performed using a communication interface, which has two ports: COM and USB, connected to the PLC and PC, respectively. The population consisted of all elements of the control circuit, which were: 20 contacts, 6 physical outputs, 3 timers, 1 marker and 1 counter; resulting in a population size of 31. The sample was chosen by the researchers' criteria and represented the 6 physical outputs. When the control circuit was executed, it was observed that the actuators turned on and off according to the specifications made in the control circuit design, thus achieving the general objective and proving the general hypothesis.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).