Ensamblaje de un prototipo de humidificador de aire automatizado con implementación de un autómata programable

Descripción del Articulo

The general objective of this thesis was: to assemble a prototype of an automated air humidifier with the implementation of a programmable automaton, consisting of: an evaporator, a programmable logic controller, a temperature controller integrated with a sensor, a relative humidity controller integ...

Descripción completa

Detalles Bibliográficos
Autores: Pérez Llerena, Ruller David, Valderrama Maldonado, Karolin Alexandra
Formato: tesis de grado
Fecha de Publicación:2025
Institución:Universidad Nacional De La Amazonía Peruana
Repositorio:UNAPIquitos-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unapiquitos.edu.pe:20.500.12737/11592
Enlace del recurso:https://hdl.handle.net/20.500.12737/11592
Nivel de acceso:acceso abierto
Materia:Control automático
Prototipos
Control de la humedad
Humedad relativa
Controladores programables
https://purl.org/pe-repo/ocde/ford#2.04.01
https://purl.org/pe-repo/ocde/ford#2.02.03
Descripción
Sumario:The general objective of this thesis was: to assemble a prototype of an automated air humidifier with the implementation of a programmable automaton, consisting of: an evaporator, a programmable logic controller, a temperature controller integrated with a sensor, a relative humidity controller integrated with a sensor, an extractor and an electric heater. This objective was achieved by designing and simulating a control circuit, considering the following order of connections in the programmable logic controller: the temperature and relative humidity sensors, the electric heater and the extractor, are connected to the inputs I3 and I4 and to the physical outputs Q1 and Q2, respectively. He results indicated that: if the water temperature (Water) is lower than the set point (80 °C), the temperature sensor contact (I3) closes, turning on the electric heater (Q1), demonstrating that there is an inverse relationship between Q1 and Water. The evaporation rate of water changes in relation to temperature and time, from (0.000635 kg/s, 33.6 °C, 0 s) to (0.000669 kg/s, 81.8 °C, 780 s) and is constant (0.000666 kg/s) for values close to the set point (80 °C). If the relative humidity (Aire) is greater than the set point (95 %), the contact of the relative humidity sensor (I4) closes turning on the extractor (Q2), verifying that there is a direct relationship between Q2 and Aire. In this way, the general objective was met and at the same time the general hypothesis was tested.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).