Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021
Descripción del Articulo
This study was conducted in Iquitos city, whose purpose was to demonstrate the feasibility of using remote technology to obtain vital signs (heart rate, temperature and oxygen saturation) in contrast to current methods of obtaining vital signs by means of a prototype device, built based on Raspberry...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2023 |
Institución: | Universidad Nacional De La Amazonía Peruana |
Repositorio: | UNAPIquitos-Institucional |
Lenguaje: | español |
OAI Identifier: | oai:repositorio.unapiquitos.edu.pe:20.500.12737/10035 |
Enlace del recurso: | https://hdl.handle.net/20.500.12737/10035 |
Nivel de acceso: | acceso abierto |
Materia: | Prototipos Telemedicina Monitoreo ambulatorio Signos vitales https://purl.org/pe-repo/ocde/ford#2.02.04 |
id |
UNAP_34bae4dfac0f86c3b6d8a9980cdec823 |
---|---|
oai_identifier_str |
oai:repositorio.unapiquitos.edu.pe:20.500.12737/10035 |
network_acronym_str |
UNAP |
network_name_str |
UNAPIquitos-Institucional |
repository_id_str |
4362 |
dc.title.es_PE.fl_str_mv |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
title |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
spellingShingle |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 Romero Arcentales, Manuel Iván Prototipos Telemedicina Monitoreo ambulatorio Signos vitales https://purl.org/pe-repo/ocde/ford#2.02.04 |
title_short |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
title_full |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
title_fullStr |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
title_full_unstemmed |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
title_sort |
Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021 |
author |
Romero Arcentales, Manuel Iván |
author_facet |
Romero Arcentales, Manuel Iván Soto Oliveira, Llento Dick |
author_role |
author |
author2 |
Soto Oliveira, Llento Dick |
author2_role |
author |
dc.contributor.advisor.fl_str_mv |
Vilca Barbarán, Rafael |
dc.contributor.author.fl_str_mv |
Romero Arcentales, Manuel Iván Soto Oliveira, Llento Dick |
dc.subject.es_PE.fl_str_mv |
Prototipos Telemedicina Monitoreo ambulatorio Signos vitales |
topic |
Prototipos Telemedicina Monitoreo ambulatorio Signos vitales https://purl.org/pe-repo/ocde/ford#2.02.04 |
dc.subject.ocde.es_PE.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.02.04 |
description |
This study was conducted in Iquitos city, whose purpose was to demonstrate the feasibility of using remote technology to obtain vital signs (heart rate, temperature and oxygen saturation) in contrast to current methods of obtaining vital signs by means of a prototype device, built based on Raspberry, arduino and sensors that allowed capturing the information of vital signs mentioned above.The research is quantitative, applied, Descriptive, with non-experimental transversal intervention with a tendency to case study with a single measurement. The study population consisted of all the records generated by the prototype to measure vital signs from July 15 to 26, the sample was non-probabilistic and was conducted through pilot tests where the indicators of precision and accuracy were recorded within the prototype variable, and for the monitoring variable, the time spent measuring temperature, SPo2 and heart rate was recorded. To determine whether the prototype was an accurate tool, the Gage R&R test with Minitab was used for each of the vital signs measured by the device, as well as the Linearity and Bias study to demonstrate that the prototype is an accurate measurement tool, and a SUS test was also carried out to calculate the degree of usability in terms of the appreciation of the medical personnel involved in the tests. The results of the experiment showed R&R values less than 20% and n > 6 which means that the tool was accurate, also P values > 0.05 and a bias within the tolerable range of measurement error according to the literature, the maximum tolerable error for the heart rate is 5bpm, temperature with 0. 5 C° and spo2 at 3%, demonstrating the accuracy of the prototype as a measurement tool, the SUS value was calculated with a total of 10 participants and the result was 83.25 out of 100 indicating that users rated our system as acceptable good. |
publishDate |
2023 |
dc.date.accessioned.none.fl_str_mv |
2024-04-16T15:59:35Z |
dc.date.available.none.fl_str_mv |
2024-04-16T15:59:35Z |
dc.date.issued.fl_str_mv |
2023 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.other.none.fl_str_mv |
005.38 R81 2023 |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12737/10035 |
identifier_str_mv |
005.38 R81 2023 |
url |
https://hdl.handle.net/20.500.12737/10035 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.*.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.*.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
dc.format.es_PE.fl_str_mv |
application/pdf |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de la Amazonía Peruana |
dc.publisher.country.es_PE.fl_str_mv |
PE |
dc.source.none.fl_str_mv |
reponame:UNAPIquitos-Institucional instname:Universidad Nacional De La Amazonía Peruana instacron:UNAPIquitos |
instname_str |
Universidad Nacional De La Amazonía Peruana |
instacron_str |
UNAPIquitos |
institution |
UNAPIquitos |
reponame_str |
UNAPIquitos-Institucional |
collection |
UNAPIquitos-Institucional |
bitstream.url.fl_str_mv |
https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/1/Manuel_Tesis_T%c3%adtulo_2023.pdf https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/2/Manuel_Formulario%20de%20Autorizacion.pdf https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/3/Manuel_Constancia%20de%20Similitud.pdf https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/4/Manuel_Constancia%20de%20Conformidad.pdf https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/5/Manuel_Tesis_T%c3%adtulo_2023.pdf.txt https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/7/Manuel_Formulario%20de%20Autorizacion.pdf.txt https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/9/Manuel_Constancia%20de%20Similitud.pdf.txt https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/11/Manuel_Constancia%20de%20Conformidad.pdf.txt https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/6/Manuel_Tesis_T%c3%adtulo_2023.pdf.jpg https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/8/Manuel_Formulario%20de%20Autorizacion.pdf.jpg https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/10/Manuel_Constancia%20de%20Similitud.pdf.jpg https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/12/Manuel_Constancia%20de%20Conformidad.pdf.jpg |
bitstream.checksum.fl_str_mv |
0bc9137c06d203d2cada4de71a0def17 0920888533ea23bec1de8246fc538924 4e527c9acf578ce34f0a40b2c5f1a383 216739bad5ff709fe5d74a89aa3ea30b 6c8fcb1b3a8b774de232678e9075e2af 9a4813f3338f89152adac4939faafadd 501ad20d0d4c6be54a58c701b0d25866 68b329da9893e34099c7d8ad5cb9c940 cd4912980c26997c91ed6412a052a2af bf6471e1bc6df337e5541a3345b49b52 ca129fccd86c05ce706b9169b28940b1 634f655aff7c440f23e4ebfef15eabb3 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Digital UNAP |
repository.mail.fl_str_mv |
repositorio.institucional@unapiquitos.edu.pe |
_version_ |
1841540500282146816 |
spelling |
Vilca Barbarán, RafaelRomero Arcentales, Manuel IvánSoto Oliveira, Llento Dick2024-04-16T15:59:35Z2024-04-16T15:59:35Z2023005.38 R81 2023https://hdl.handle.net/20.500.12737/10035This study was conducted in Iquitos city, whose purpose was to demonstrate the feasibility of using remote technology to obtain vital signs (heart rate, temperature and oxygen saturation) in contrast to current methods of obtaining vital signs by means of a prototype device, built based on Raspberry, arduino and sensors that allowed capturing the information of vital signs mentioned above.The research is quantitative, applied, Descriptive, with non-experimental transversal intervention with a tendency to case study with a single measurement. The study population consisted of all the records generated by the prototype to measure vital signs from July 15 to 26, the sample was non-probabilistic and was conducted through pilot tests where the indicators of precision and accuracy were recorded within the prototype variable, and for the monitoring variable, the time spent measuring temperature, SPo2 and heart rate was recorded. To determine whether the prototype was an accurate tool, the Gage R&R test with Minitab was used for each of the vital signs measured by the device, as well as the Linearity and Bias study to demonstrate that the prototype is an accurate measurement tool, and a SUS test was also carried out to calculate the degree of usability in terms of the appreciation of the medical personnel involved in the tests. The results of the experiment showed R&R values less than 20% and n > 6 which means that the tool was accurate, also P values > 0.05 and a bias within the tolerable range of measurement error according to the literature, the maximum tolerable error for the heart rate is 5bpm, temperature with 0. 5 C° and spo2 at 3%, demonstrating the accuracy of the prototype as a measurement tool, the SUS value was calculated with a total of 10 participants and the result was 83.25 out of 100 indicating that users rated our system as acceptable good.Este estudio se realizó en la ciudad de Iquitos, cuya finalidad fue demostrar la viabilidad de la utilización de la tecnología remota para la obtención de signos vitales (Ritmo Cardiaco, temperatura y saturación de oxígeno) en contraste con los métodos actuales de obtención de signos vitales por medio de un dispositivo prototipo, construido a base de Raspberry, Arduino y sensores que permitieron capturar la información de signos vitales mencionados anteriormente. La investigación fue cuantitativa, aplicada, descriptiva, con intervención no experimental transversal con tendencia a estudio de caso con una sola medición. La población de estudio se compuso por todos los registros generados por el prototipo para medir los signos vitales desde 15 al 26 de julio, la muestra fue no probabilística dirigida por conveniencia del investigador y se llevó a cabo mediante pruebas piloto donde se registraron dentro de la variable prototipo los indicadores de precisión y exactitud y para la variable monitoreo se registró el tiempo empleado para medir la temperatura, SPo2 y pulso cardiaco. Para determinar si el prototipo era una herramienta precisa se utilizó la prueba Gage R&R con Minitab para cada uno de los signos vitales medidos por el dispositivo, de igual forma se utilizó el estudio de Linealidad y Sesgo para demostrar que el prototipo es una herramienta de medición exacta, además se llevó a cabo una prueba SUS con el objetivo de calcular el grado de usabilidad en cuanto a la apreciación del personal médico implicado en las pruebas. Los resultados del experimento demostraron valores de R&R menores al 20% y n > 6, lo que quiere decir que la herramienta era precisa, asimismo valores de P > 0.05 y un sesgo dentro del rango tolerable de error de medición según la bibliografía, el máximo error tolerable para la frecuencia cardiaca es de 5bpm, temperatura con 0.5 C° y spo2 al 3%, demostrando la exactitud del prototipo como herramienta de medición, el valor SUS fue calculado con un total de 10 participantes y el resultado fue de 83.25 sobre 100 lo que indica que los usuarios calificaron a nuestro sistema como aceptable.application/pdfspaUniversidad Nacional de la Amazonía PeruanaPEinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/PrototiposTelemedicinaMonitoreo ambulatorioSignos vitaleshttps://purl.org/pe-repo/ocde/ford#2.02.04Prototipo para monitoreo de signos vitales enfocado a la atención de pacientes no hospitalizados en la ciudad de Iquitos 2021info:eu-repo/semantics/bachelorThesisreponame:UNAPIquitos-Institucionalinstname:Universidad Nacional De La Amazonía Peruanainstacron:UNAPIquitosSUNEDUIngeniería de Sistemas e InformáticaUniversidad Nacional de la Amazonía Peruana. Facultad de AgronomíaIngeniero(a) de Sistemas e Informática7092165170429350https://orcid.org/0000-0003-0405-256441372787https://purl.org/pe-repo/renati/type#tesis612156https://purl.org/pe-repo/renati/level#tituloProfesionalPita Astengo, Luis HonoratoMarthans Ruiz, Angel AlbertoBardales Lozano, Tonny EduardoORIGINALManuel_Tesis_Título_2023.pdfManuel_Tesis_Título_2023.pdfTexto completoapplication/pdf2436491https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/1/Manuel_Tesis_T%c3%adtulo_2023.pdf0bc9137c06d203d2cada4de71a0def17MD51Manuel_Formulario de Autorizacion.pdfManuel_Formulario de Autorizacion.pdfapplication/pdf432558https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/2/Manuel_Formulario%20de%20Autorizacion.pdf0920888533ea23bec1de8246fc538924MD52Manuel_Constancia de Similitud.pdfManuel_Constancia de Similitud.pdfapplication/pdf2287624https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/3/Manuel_Constancia%20de%20Similitud.pdf4e527c9acf578ce34f0a40b2c5f1a383MD53Manuel_Constancia de Conformidad.pdfManuel_Constancia de Conformidad.pdfapplication/pdf146740https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/4/Manuel_Constancia%20de%20Conformidad.pdf216739bad5ff709fe5d74a89aa3ea30bMD54TEXTManuel_Tesis_Título_2023.pdf.txtManuel_Tesis_Título_2023.pdf.txtExtracted texttext/plain114784https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/5/Manuel_Tesis_T%c3%adtulo_2023.pdf.txt6c8fcb1b3a8b774de232678e9075e2afMD55Manuel_Formulario de Autorizacion.pdf.txtManuel_Formulario de Autorizacion.pdf.txtExtracted texttext/plain6923https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/7/Manuel_Formulario%20de%20Autorizacion.pdf.txt9a4813f3338f89152adac4939faafaddMD57Manuel_Constancia de Similitud.pdf.txtManuel_Constancia de Similitud.pdf.txtExtracted texttext/plain78904https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/9/Manuel_Constancia%20de%20Similitud.pdf.txt501ad20d0d4c6be54a58c701b0d25866MD59Manuel_Constancia de Conformidad.pdf.txtManuel_Constancia de Conformidad.pdf.txtExtracted texttext/plain1https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/11/Manuel_Constancia%20de%20Conformidad.pdf.txt68b329da9893e34099c7d8ad5cb9c940MD511THUMBNAILManuel_Tesis_Título_2023.pdf.jpgManuel_Tesis_Título_2023.pdf.jpgGenerated Thumbnailimage/jpeg3194https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/6/Manuel_Tesis_T%c3%adtulo_2023.pdf.jpgcd4912980c26997c91ed6412a052a2afMD56Manuel_Formulario de Autorizacion.pdf.jpgManuel_Formulario de Autorizacion.pdf.jpgGenerated Thumbnailimage/jpeg3641https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/8/Manuel_Formulario%20de%20Autorizacion.pdf.jpgbf6471e1bc6df337e5541a3345b49b52MD58Manuel_Constancia de Similitud.pdf.jpgManuel_Constancia de Similitud.pdf.jpgGenerated Thumbnailimage/jpeg3836https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/10/Manuel_Constancia%20de%20Similitud.pdf.jpgca129fccd86c05ce706b9169b28940b1MD510Manuel_Constancia de Conformidad.pdf.jpgManuel_Constancia de Conformidad.pdf.jpgGenerated Thumbnailimage/jpeg3828https://repositorio.unapiquitos.edu.pe/bitstream/20.500.12737/10035/12/Manuel_Constancia%20de%20Conformidad.pdf.jpg634f655aff7c440f23e4ebfef15eabb3MD51220.500.12737/10035oai:repositorio.unapiquitos.edu.pe:20.500.12737/100352024-04-16 13:31:41.985Repositorio Digital UNAPrepositorio.institucional@unapiquitos.edu.pe |
score |
13.439101 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).