The predictive philosophy contributes to improving productivity, reducing system failures and reducing unplanned downtime in a non-invasive way to the machine, for which the test bench is based on the German standard VDI2221, using mathematical models to select the materials and the design of the fi...

Descripción completa

Detalles Bibliográficos
Autores: Vilchez Becerra, Kevin Ricardo, Perez Cardenas, Edson Jeanpierre
Formato: tesis de grado
Fecha de Publicación:2021
Institución:Universidad Continental
Repositorio:CONTINENTAL-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.continental.edu.pe:20.500.12394/10452
Enlace del recurso:https://hdl.handle.net/20.500.12394/10452
https://doi.org/10.1088/1742-6596/1877/1/012005
Nivel de acceso:acceso abierto
Materia:Tiempos de inactividad
Análisis de vibraciones
http://purl.org/pe-repo/ocde/ford#2.03.01
Descripción
Sumario:The predictive philosophy contributes to improving productivity, reducing system failures and reducing unplanned downtime in a non-invasive way to the machine, for which the test bench is based on the German standard VDI2221, using mathematical models to select the materials and the design of the final prototype. The development of the project consists of applying vibration analysis, thermographic analysis and the quality of energy in which each measurement and the correlation that exist between them is shown; in addition, the inverse Fourier transform was used to demonstrate the amplitude and frequency ranges according to the theoretical equation proposed in the Matlab program, it can also be seen the higher order vibrations of 22.1 is located at the same critical point of the SP7 measurement with a temperature of 34.6 ° C and an emissivity of 0.95, likewise the Power quality measurements are within the allowable limits according to ISO 50001; On the other hand, this analysis made it possible to determine the existence of a positive linear correlation between thermography and vibration analyzes with a correlation coefficient equal to 0.828.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).