Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru

Descripción del Articulo

In recent years, the occurrence of unexpected meteorological events during the dry season and population growth have generated shortages in the supply of drinking water in the city of Pampas. This situation led us to look for new search strategies for natural water sources, even underground. Faced w...

Descripción completa

Detalles Bibliográficos
Autores: Chavez Pacheco, Maria del Pilar, Caysahuana Flores, Jhoel Anderson, Julian Salvador, Diego Jose, Mallma Capcha, Tito
Formato: tesis de grado
Fecha de Publicación:2023
Institución:Universidad Continental
Repositorio:CONTINENTAL-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.continental.edu.pe:20.500.12394/13289
Enlace del recurso:https://hdl.handle.net/20.500.12394/13289
https://doi.org/10.13189/cea.2023.110423
Nivel de acceso:acceso abierto
Materia:Hidrogeología
Electricidad
Aguas subterráneas
https://purl.org/pe-repo/ocde/ford#2.01.01
id UCON_7e8728c8668a4c567188679c2f496f1c
oai_identifier_str oai:repositorio.continental.edu.pe:20.500.12394/13289
network_acronym_str UCON
network_name_str CONTINENTAL-Institucional
repository_id_str 4517
dc.title.es_PE.fl_str_mv Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
title Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
spellingShingle Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
Chavez Pacheco, Maria del Pilar
Hidrogeología
Electricidad
Aguas subterráneas
https://purl.org/pe-repo/ocde/ford#2.01.01
title_short Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
title_full Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
title_fullStr Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
title_full_unstemmed Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
title_sort Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru
author Chavez Pacheco, Maria del Pilar
author_facet Chavez Pacheco, Maria del Pilar
Caysahuana Flores, Jhoel Anderson
Julian Salvador, Diego Jose
Mallma Capcha, Tito
author_role author
author2 Caysahuana Flores, Jhoel Anderson
Julian Salvador, Diego Jose
Mallma Capcha, Tito
author2_role author
author
author
dc.contributor.advisor.fl_str_mv Mallma Capcha, Tito
dc.contributor.author.fl_str_mv Chavez Pacheco, Maria del Pilar
Caysahuana Flores, Jhoel Anderson
Julian Salvador, Diego Jose
Mallma Capcha, Tito
dc.subject.es_PE.fl_str_mv Hidrogeología
Electricidad
Aguas subterráneas
topic Hidrogeología
Electricidad
Aguas subterráneas
https://purl.org/pe-repo/ocde/ford#2.01.01
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.01.01
description In recent years, the occurrence of unexpected meteorological events during the dry season and population growth have generated shortages in the supply of drinking water in the city of Pampas. This situation led us to look for new search strategies for natural water sources, even underground. Faced with this problem, the possibility of detecting and parameterizing these sources was raised, while the design of a tubular well was raised that allows the economic extraction of water from the aquifer studied through the use of geophysical techniques, generating profile images of geological maps. of the strata and the location of the possible water table of the study area. The preferred locations for locating groundwater collections are alluvial fans and fractured valley bottoms. Using the Schlumberger array, eleven (11) VESs have been made, up to a depth of 150 m. For the field tests, a resistivity meter that we have manufactured by hand was used, this will emit current to the subsoil obtaining layers and horizons through their resistivities, these values vary in the range of 6.32-125.23 Ω.m. The PQWTS-150- Water Detector equipment was also used to measure the depth of the semi-confined aquifer and to know its groundwater flow, the value is 33.33 l/s, this value refers to the three celestial layers that can be seen in the image. description of the profile of the geological map, in this profile clayey, silty, sandy, gravel soils and a combination of them were found. This point 11 was taken in the nursery of the Daniel Hernández district, this area is flat, quite humid and its depth is 51m -115m. In addition, this aquifer has good hydrogeological possibilities making surface recharge possible. The water table was also determined, it is found at a depth of 4-8 m. With the data obtained lines above it was useful for the calculation and design of the tubular well. In conclusion, the designed well has a depth of 115 m and a thickness of 64 m, with a drilling diameter of 18 inches and equipped with a submersible pump with a 25 HP motor, achieving a flow rate of 1000 l/min, which complies with the water requirement of the population. In order to verify the quality of the water from this well, a physical-chemical and bacteriological analysis was carried out.
publishDate 2023
dc.date.accessioned.none.fl_str_mv 2023-09-06T14:33:02Z
dc.date.available.none.fl_str_mv 2023-09-06T14:33:02Z
dc.date.issued.fl_str_mv 2023
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.version.es_PE.fl_str_mv info:eu-repo/semantics/publishedVersion
format bachelorThesis
status_str publishedVersion
dc.identifier.citation.es_PE.fl_str_mv Chavez, M., Caysahuana, Jh., Julian, D. y Mallma, T. (2023). Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru. Tesis para optar el título profesional de Ingeniería Civil, Escuela Académico Profesional de Ingeniero Civil, Universidad Continental, Huancayo, Perú.
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12394/13289
dc.identifier.journal.es_PE.fl_str_mv Civil Engineering and Architecture
dc.identifier.doi.none.fl_str_mv https://doi.org/10.13189/cea.2023.110423
identifier_str_mv Chavez, M., Caysahuana, Jh., Julian, D. y Mallma, T. (2023). Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru. Tesis para optar el título profesional de Ingeniería Civil, Escuela Académico Profesional de Ingeniero Civil, Universidad Continental, Huancayo, Perú.
Civil Engineering and Architecture
url https://hdl.handle.net/20.500.12394/13289
https://doi.org/10.13189/cea.2023.110423
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.relation.es_PE.fl_str_mv https://www.hrpub.org/journals/article_info.php?aid=13227
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv https://creativecommons.org/licenses/by/4.0/
dc.rights.license.es_PE.fl_str_mv Attribution 4.0 International (CC BY 4.0)
dc.rights.accessRights.es_PE.fl_str_mv Acceso abierto
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
Attribution 4.0 International (CC BY 4.0)
Acceso abierto
dc.format.es_PE.fl_str_mv application/pdf
dc.format.extent.es_PE.fl_str_mv p. 1984-2006
dc.publisher.es_PE.fl_str_mv Universidad Continental
dc.publisher.country.es_PE.fl_str_mv PE
dc.source.es_PE.fl_str_mv Universidad Continental
Repositorio Institucional - Continental
dc.source.none.fl_str_mv reponame:CONTINENTAL-Institucional
instname:Universidad Continental
instacron:CONTINENTAL
instname_str Universidad Continental
instacron_str CONTINENTAL
institution CONTINENTAL
reponame_str CONTINENTAL-Institucional
collection CONTINENTAL-Institucional
bitstream.url.fl_str_mv https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/4/IV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.txt
https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/6/IV_FIN_105_Autorizaci%c3%b3n_2023.pdf.txt
https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/5/IV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.jpg
https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/7/IV_FIN_105_Autorizaci%c3%b3n_2023.pdf.jpg
https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/1/IV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf
https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/2/IV_FIN_105_Autorizaci%c3%b3n_2023.pdf
https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/3/license.txt
bitstream.checksum.fl_str_mv 992143818f1d8a048e94d603bb8aa671
60817736a88f3227eac13aaedc909d8f
68263f88fb8df9cc45a9ca794f3a06a6
a7ce4a24b9ec84a3786e7e7c967b9ff3
4d6bc9ffb30c07f85d91b4c87a70593a
7084151b7fd60bd27158a9d801082b30
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Continental
repository.mail.fl_str_mv dspaceconti@continental.edu.pe
_version_ 1847275880489943040
spelling Mallma Capcha, TitoChavez Pacheco, Maria del PilarCaysahuana Flores, Jhoel AndersonJulian Salvador, Diego JoseMallma Capcha, Tito2023-09-06T14:33:02Z2023-09-06T14:33:02Z2023Chavez, M., Caysahuana, Jh., Julian, D. y Mallma, T. (2023). Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peru. Tesis para optar el título profesional de Ingeniería Civil, Escuela Académico Profesional de Ingeniero Civil, Universidad Continental, Huancayo, Perú.https://hdl.handle.net/20.500.12394/13289Civil Engineering and Architecturehttps://doi.org/10.13189/cea.2023.110423In recent years, the occurrence of unexpected meteorological events during the dry season and population growth have generated shortages in the supply of drinking water in the city of Pampas. This situation led us to look for new search strategies for natural water sources, even underground. Faced with this problem, the possibility of detecting and parameterizing these sources was raised, while the design of a tubular well was raised that allows the economic extraction of water from the aquifer studied through the use of geophysical techniques, generating profile images of geological maps. of the strata and the location of the possible water table of the study area. The preferred locations for locating groundwater collections are alluvial fans and fractured valley bottoms. Using the Schlumberger array, eleven (11) VESs have been made, up to a depth of 150 m. For the field tests, a resistivity meter that we have manufactured by hand was used, this will emit current to the subsoil obtaining layers and horizons through their resistivities, these values vary in the range of 6.32-125.23 Ω.m. The PQWTS-150- Water Detector equipment was also used to measure the depth of the semi-confined aquifer and to know its groundwater flow, the value is 33.33 l/s, this value refers to the three celestial layers that can be seen in the image. description of the profile of the geological map, in this profile clayey, silty, sandy, gravel soils and a combination of them were found. This point 11 was taken in the nursery of the Daniel Hernández district, this area is flat, quite humid and its depth is 51m -115m. In addition, this aquifer has good hydrogeological possibilities making surface recharge possible. The water table was also determined, it is found at a depth of 4-8 m. With the data obtained lines above it was useful for the calculation and design of the tubular well. In conclusion, the designed well has a depth of 115 m and a thickness of 64 m, with a drilling diameter of 18 inches and equipped with a submersible pump with a 25 HP motor, achieving a flow rate of 1000 l/min, which complies with the water requirement of the population. In order to verify the quality of the water from this well, a physical-chemical and bacteriological analysis was carried out.application/pdfp. 1984-2006engUniversidad ContinentalPEhttps://www.hrpub.org/journals/article_info.php?aid=13227SUNEDUinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/Attribution 4.0 International (CC BY 4.0)Acceso abiertoUniversidad ContinentalRepositorio Institucional - Continentalreponame:CONTINENTAL-Institucionalinstname:Universidad Continentalinstacron:CONTINENTALHidrogeologíaElectricidadAguas subterráneashttps://purl.org/pe-repo/ocde/ford#2.01.01Vertical Electrical Sounding Method to Detect Groundwater and Design of A Tubular Well for the Pampas District – Peruinfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/publishedVersionIngeniero CivilUniversidad Continental. Facultad de Ingeniería.Ingeniería CivilPregrado presencial regular20012015https://orcid.org/0000-0001-7301-889146598211741649957011652620012015732016https://purl.org/pe-repo/renati/level#tituloProfesionalhttps://purl.org/pe-repo/renati/type#tesisTEXTIV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.txtIV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.txtExtracted texttext/plain51913https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/4/IV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.txt992143818f1d8a048e94d603bb8aa671MD54IV_FIN_105_Autorización_2023.pdf.txtIV_FIN_105_Autorización_2023.pdf.txtExtracted texttext/plain3472https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/6/IV_FIN_105_Autorizaci%c3%b3n_2023.pdf.txt60817736a88f3227eac13aaedc909d8fMD56THUMBNAILIV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.jpgIV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.jpgGenerated Thumbnailimage/jpeg2768https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/5/IV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf.jpg68263f88fb8df9cc45a9ca794f3a06a6MD55IV_FIN_105_Autorización_2023.pdf.jpgIV_FIN_105_Autorización_2023.pdf.jpgGenerated Thumbnailimage/jpeg4076https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/7/IV_FIN_105_Autorizaci%c3%b3n_2023.pdf.jpga7ce4a24b9ec84a3786e7e7c967b9ff3MD57ORIGINALIV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdfIV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdfChavez Pacheco, Maria del Pilar; Caysahuana Flores, Jhoel Anderson; Julian Salvador, Diego Jose; Mallma Capcha, Titoapplication/pdf1857867https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/1/IV_FIN_105_TE_Chavez_Caysahuana_Julian_Mallma_2023.pdf4d6bc9ffb30c07f85d91b4c87a70593aMD51IV_FIN_105_Autorización_2023.pdfIV_FIN_105_Autorización_2023.pdfAutorizaciónapplication/pdf111665https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/2/IV_FIN_105_Autorizaci%c3%b3n_2023.pdf7084151b7fd60bd27158a9d801082b30MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.continental.edu.pe/bitstream/20.500.12394/13289/3/license.txt8a4605be74aa9ea9d79846c1fba20a33MD5320.500.12394/13289oai:repositorio.continental.edu.pe:20.500.12394/132892023-09-20 03:02:45.231Repositorio Continentaldspaceconti@continental.edu.peTk9URTogUExBQ0UgWU9VUiBPV04gTElDRU5TRSBIRVJFClRoaXMgc2FtcGxlIGxpY2Vuc2UgaXMgcHJvdmlkZWQgZm9yIGluZm9ybWF0aW9uYWwgcHVycG9zZXMgb25seS4KCk5PTi1FWENMVVNJVkUgRElTVFJJQlVUSU9OIExJQ0VOU0UKCkJ5IHNpZ25pbmcgYW5kIHN1Ym1pdHRpbmcgdGhpcyBsaWNlbnNlLCB5b3UgKHRoZSBhdXRob3Iocykgb3IgY29weXJpZ2h0Cm93bmVyKSBncmFudHMgdG8gRFNwYWNlIFVuaXZlcnNpdHkgKERTVSkgdGhlIG5vbi1leGNsdXNpdmUgcmlnaHQgdG8gcmVwcm9kdWNlLAp0cmFuc2xhdGUgKGFzIGRlZmluZWQgYmVsb3cpLCBhbmQvb3IgZGlzdHJpYnV0ZSB5b3VyIHN1Ym1pc3Npb24gKGluY2x1ZGluZwp0aGUgYWJzdHJhY3QpIHdvcmxkd2lkZSBpbiBwcmludCBhbmQgZWxlY3Ryb25pYyBmb3JtYXQgYW5kIGluIGFueSBtZWRpdW0sCmluY2x1ZGluZyBidXQgbm90IGxpbWl0ZWQgdG8gYXVkaW8gb3IgdmlkZW8uCgpZb3UgYWdyZWUgdGhhdCBEU1UgbWF5LCB3aXRob3V0IGNoYW5naW5nIHRoZSBjb250ZW50LCB0cmFuc2xhdGUgdGhlCnN1Ym1pc3Npb24gdG8gYW55IG1lZGl1bSBvciBmb3JtYXQgZm9yIHRoZSBwdXJwb3NlIG9mIHByZXNlcnZhdGlvbi4KCllvdSBhbHNvIGFncmVlIHRoYXQgRFNVIG1heSBrZWVwIG1vcmUgdGhhbiBvbmUgY29weSBvZiB0aGlzIHN1Ym1pc3Npb24gZm9yCnB1cnBvc2VzIG9mIHNlY3VyaXR5LCBiYWNrLXVwIGFuZCBwcmVzZXJ2YXRpb24uCgpZb3UgcmVwcmVzZW50IHRoYXQgdGhlIHN1Ym1pc3Npb24gaXMgeW91ciBvcmlnaW5hbCB3b3JrLCBhbmQgdGhhdCB5b3UgaGF2ZQp0aGUgcmlnaHQgdG8gZ3JhbnQgdGhlIHJpZ2h0cyBjb250YWluZWQgaW4gdGhpcyBsaWNlbnNlLiBZb3UgYWxzbyByZXByZXNlbnQKdGhhdCB5b3VyIHN1Ym1pc3Npb24gZG9lcyBub3QsIHRvIHRoZSBiZXN0IG9mIHlvdXIga25vd2xlZGdlLCBpbmZyaW5nZSB1cG9uCmFueW9uZSdzIGNvcHlyaWdodC4KCklmIHRoZSBzdWJtaXNzaW9uIGNvbnRhaW5zIG1hdGVyaWFsIGZvciB3aGljaCB5b3UgZG8gbm90IGhvbGQgY29weXJpZ2h0LAp5b3UgcmVwcmVzZW50IHRoYXQgeW91IGhhdmUgb2J0YWluZWQgdGhlIHVucmVzdHJpY3RlZCBwZXJtaXNzaW9uIG9mIHRoZQpjb3B5cmlnaHQgb3duZXIgdG8gZ3JhbnQgRFNVIHRoZSByaWdodHMgcmVxdWlyZWQgYnkgdGhpcyBsaWNlbnNlLCBhbmQgdGhhdApzdWNoIHRoaXJkLXBhcnR5IG93bmVkIG1hdGVyaWFsIGlzIGNsZWFybHkgaWRlbnRpZmllZCBhbmQgYWNrbm93bGVkZ2VkCndpdGhpbiB0aGUgdGV4dCBvciBjb250ZW50IG9mIHRoZSBzdWJtaXNzaW9uLgoKSUYgVEhFIFNVQk1JU1NJT04gSVMgQkFTRUQgVVBPTiBXT1JLIFRIQVQgSEFTIEJFRU4gU1BPTlNPUkVEIE9SIFNVUFBPUlRFRApCWSBBTiBBR0VOQ1kgT1IgT1JHQU5JWkFUSU9OIE9USEVSIFRIQU4gRFNVLCBZT1UgUkVQUkVTRU5UIFRIQVQgWU9VIEhBVkUKRlVMRklMTEVEIEFOWSBSSUdIVCBPRiBSRVZJRVcgT1IgT1RIRVIgT0JMSUdBVElPTlMgUkVRVUlSRUQgQlkgU1VDSApDT05UUkFDVCBPUiBBR1JFRU1FTlQuCgpEU1Ugd2lsbCBjbGVhcmx5IGlkZW50aWZ5IHlvdXIgbmFtZShzKSBhcyB0aGUgYXV0aG9yKHMpIG9yIG93bmVyKHMpIG9mIHRoZQpzdWJtaXNzaW9uLCBhbmQgd2lsbCBub3QgbWFrZSBhbnkgYWx0ZXJhdGlvbiwgb3RoZXIgdGhhbiBhcyBhbGxvd2VkIGJ5IHRoaXMKbGljZW5zZSwgdG8geW91ciBzdWJtaXNzaW9uLgo=
score 13.402391
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).