Efectividad de un protector de lúmenes del catéter venoso central en un Servicio de Cuidados Intensivos Pediátricos

Descripción del Articulo

The research project arises when observing the insufficient protection of the lumens of the CVC central venous catheter by the protector often used in the services; which ends up leaving the lumens to the environment despite using adhesive tape, in front of which a central venous catheter lumens pro...

Descripción completa

Detalles Bibliográficos
Autor: Polo Bermúdez, Wendy Lizbeth
Fecha de Publicación:2021
Institución:Universidad Peruana Cayetano Heredia
Repositorio:UPCH-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.upch.edu.pe:20.500.12866/9019
Enlace del recurso:https://hdl.handle.net/20.500.12866/9019
Nivel de acceso:acceso abierto
Materia:Protector
Lúmenes
Catéter Venoso Central
https://purl.org/pe-repo/ocde/ford#3.02.03
https://purl.org/pe-repo/ocde/ford#3.02.08
https://purl.org/pe-repo/ocde/ford#3.03.03
Descripción
Sumario:The research project arises when observing the insufficient protection of the lumens of the CVC central venous catheter by the protector often used in the services; which ends up leaving the lumens to the environment despite using adhesive tape, in front of which a central venous catheter lumens protector is created that fulfills its objective: the protection of the CVC lumens; the present study aims to determine the effectiveness of a lumen protector of the central venous catheter in a pediatric intensive care service. The study is quantitative, the analytical level, quasiexperimental and cross-sectional design. The population will be made up of the total of protectors used during the month of July, which according to statistics from the cardiovascular ICU service of the National Institute of Children's Health San Borja are estimated at 420 protectors (since 14 patients with CVC are treated daily) and the sample will consist of 116 protectors, of which 58 will be the conventional protectors and 58 will be the proposed protectors, these protectors will be selected by means of a non-probability sampling. To determine the effectiveness of the lumen protector, the Chi-square statistical test will be used and work will be carried out at a statistical significance level of 0.05. The results will be presented in tables and graphs. The effectiveness of the protector demonstrated by the study will allow us to have a material that contributes to the safety in the care of the central catheters.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).