Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings

Descripción del Articulo

Tires out of use (NFU) and its management is a problem in many countries of the world, and even developing countries like Perú , for lack of separate collection and proper management system. Fluid catalytic cracking catalyst (FCC) a waste product of the oil industry and can be obtained from refiner...

Descripción completa

Detalles Bibliográficos
Autores: Paya, Jordi, Gudiel, Edwin, Borrachero, Victoria, Monzó, José María
Formato: artículo
Fecha de Publicación:2016
Institución:Universidad Privada de Tacna
Repositorio:Revistas - Universidad Privada de Tacna
Lenguaje:español
OAI Identifier:oai:ojs2.172.30.101.191:article/313
Enlace del recurso:https://revistas.upt.edu.pe/ojs/index.php/arquitek/article/view/313
Nivel de acceso:acceso abierto
id REVUPT_d520f945ee89cc5d8f9f9d89433eeb69
oai_identifier_str oai:ojs2.172.30.101.191:article/313
network_acronym_str REVUPT
network_name_str Revistas - Universidad Privada de Tacna
repository_id_str
spelling Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildingsAprovechamiento de fibras de neumático fuera de uso en composites con base cemento pórtland aplicados en edificaciónPaya, JordiGudiel, EdwinBorrachero, VictoriaMonzó, José MaríaTires out of use (NFU) and its management is a problem in many countries of the world, and even developing countries like Perú , for lack of separate collection and proper management system. Fluid catalytic cracking catalyst (FCC) a waste product of the oil industry and can be obtained from refineries PetroPerú . Portland cement mortars were experienced with tire incorporating fibers (FN) as a substitute for aggregate (siliceous limestone) in a proportion of 25% by volume and 100% mortars FN. The results show a loss of workability and trials show that this material can be used in construction applications improving their thermal properties and reaching compressive strength values ranging from 25.68 to 9.30 MPa. Acceptable values to produce masonry units. The use of tire fibers (FN) in Portland cement mortars (CP) and CP-FCC feedstock can be a good ecological alternative and obtain unconventional precast low economic and environmental cost.Los neumáticos fuera de uso (NFU) y su gestión es un problema en muchos de los países del mundo, y más aun de países en vías de desarrollo como Perú , por la falta de una recogida selectiva y un adecuado sistema de gestión. El catalizador gastado de craqueo catalítico (FCC) es un residuo producto de la industria del petróleo y se puede obtener de las refinerías de PetroPerú . Se experimentaron morteros de cemento portland con incorporación de fibras de neumático (FN) como sustituto de árido (silı́ceo y calizo) en un porcentaje de 25% en volumen y morteros con 100% FN. Los resultados obtenidos manifiestan una perdida de trabajabilidad y los ensayos realizados muestran que este material puede usarse en aplicaciones constructivas, mejorando sus propiedades térmicas y alcanzando valores de resistencia a compresión que varían desde 25.68 a 9.30 MPa. valores aceptables para poder fabricar unidades de albañilería. El uso de fibras de neumático (FN) dentro de morteros de cemento portland (CP) y CP-FCC como materia prima, puede ser una buena alternativa ecológica y ası́ obtener elementos prefabricados no convencionales de bajo coste económico y medio ambiental.Universidad Privada de Tacna2016-11-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/arquitek/article/view/313Arquitek; Núm. 11 (2016): Arquitek; pp 07-14Arquitek; No 11 (2016): Arquirtek; pp 07-142617-08922073-8811reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/arquitek/article/view/313/284info:eu-repo/semantics/openAccessoai:ojs2.172.30.101.191:article/3132022-11-21T00:59:03Z
dc.title.none.fl_str_mv Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
Aprovechamiento de fibras de neumático fuera de uso en composites con base cemento pórtland aplicados en edificación
title Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
spellingShingle Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
Paya, Jordi
title_short Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
title_full Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
title_fullStr Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
title_full_unstemmed Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
title_sort Utilization of end-of-life tire fibers in Portland cement-based composites applied in buildings
dc.creator.none.fl_str_mv Paya, Jordi
Gudiel, Edwin
Borrachero, Victoria
Monzó, José María
author Paya, Jordi
author_facet Paya, Jordi
Gudiel, Edwin
Borrachero, Victoria
Monzó, José María
author_role author
author2 Gudiel, Edwin
Borrachero, Victoria
Monzó, José María
author2_role author
author
author
description Tires out of use (NFU) and its management is a problem in many countries of the world, and even developing countries like Perú , for lack of separate collection and proper management system. Fluid catalytic cracking catalyst (FCC) a waste product of the oil industry and can be obtained from refineries PetroPerú . Portland cement mortars were experienced with tire incorporating fibers (FN) as a substitute for aggregate (siliceous limestone) in a proportion of 25% by volume and 100% mortars FN. The results show a loss of workability and trials show that this material can be used in construction applications improving their thermal properties and reaching compressive strength values ranging from 25.68 to 9.30 MPa. Acceptable values to produce masonry units. The use of tire fibers (FN) in Portland cement mortars (CP) and CP-FCC feedstock can be a good ecological alternative and obtain unconventional precast low economic and environmental cost.
publishDate 2016
dc.date.none.fl_str_mv 2016-11-02
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.upt.edu.pe/ojs/index.php/arquitek/article/view/313
url https://revistas.upt.edu.pe/ojs/index.php/arquitek/article/view/313
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.upt.edu.pe/ojs/index.php/arquitek/article/view/313/284
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Privada de Tacna
publisher.none.fl_str_mv Universidad Privada de Tacna
dc.source.none.fl_str_mv Arquitek; Núm. 11 (2016): Arquitek; pp 07-14
Arquitek; No 11 (2016): Arquirtek; pp 07-14
2617-0892
2073-8811
reponame:Revistas - Universidad Privada de Tacna
instname:Universidad Privada de Tacna
instacron:UPT
instname_str Universidad Privada de Tacna
instacron_str UPT
institution UPT
reponame_str Revistas - Universidad Privada de Tacna
collection Revistas - Universidad Privada de Tacna
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1771324561493590016
score 13.955691
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).